HomeMy WebLinkAbout0943 Permittee: Harbour Ridge Ltd.
Permit Number: 560707729 .
.
SPECIFIC COI~IDITIONS t
~
I0. An effective mesns of turbidity control shall be ~
utilized during all construction activiti~s which may result in ~
violations of State Water Qualfty Standarde. (Florida
Administrative Code Rule 17-3.)
MONITORING REQUIRED:
Water Quality
. • i
Description: Dissolved oxygen, oils and greases, total and fecal
colifona.
Freguency: Quarterly. A dissolved oxygen diel sampling
program, with the first sample taken within one hour
of sunrise and continuing at four hour intervals for
a 24 hour period. Oils and greases, and total and
fecal coliform to be sampled for a minimum of once
during each diel period. The fizst samplinq date is
to be iim?ediately after construction and prior to
occupancy of the respective dock. Subsequent
quar~erly sampling shall commence immediately for
dock #1. Subsequent quarterly sampling foz dock ~2
shall begin when 50$ of the sZips are sold.
Sampling sha12 continue until a decision is made on
the constru~tion of docks #3 and #4.
Location: At 2ocations A, B, C, and D shown in the permit
diagrams at surf ace, mid-depth and one ft. above
bot tota .
Sediment and Bioloqical Analysis
Description: Biological Inteqrity (Shannon-Weaver diversity
index). Sampling and analysis to be done in
accordance with F.A.C. Rule 17-3.121t7). '
Description: Hulk and elutriate sediment analysis for copper and
lead taken fzom the top -6 to 8 inches of the
sediment ptof i le. All sampling is to be done in
accordance with the attached recommended
procedures.
ATTACHMENT(S)
PAGE ~ OF ~ p,~^ C ~S
SSLL No ~~~1 ~
;
~
,
`~o~K505 ~ ;~E ~~7
~ .
. ~Qr.-. . .
~ . -
_ _ _
.
. . ~