Loading...
HomeMy WebLinkAboutProduct Approval e f Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w... BCI�S Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCiS Site Map Links Search d bp' rf �'"t�Product Approval �]-; tom""�USER:Public User Product Approval Menu>Product or Application Searrh>Application LM>Application Detail FL FL10976-116 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Kaede McLaughlin fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By American Architectural Manufacturers Association Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 04/23/2015 Date Validated 05/29/2015 Date Pending FBC Approval 1 of 2 01/31/2017 10:02 AM Florida Building Code Online https://www.floridabuilding-org/pr/pr_app_dtl.aspx?param—w... Date Approved 06/02/2015 Summary of Products i FL# I Model,Number or Name ;Description 10976.1 i Premium Atlantic Vinyl (Bypass Sliding Patio Door(3800) 190.625"x 95.5"Insulated Glass(3/16"-3/16"Tempered)(Safety Glazing) i_--------------- Limits ------..__Limits of Use i Certification Agency Certificate Approved for use in HVHZ:No FL10976 R6 C CAC OXXX LC-PG50-190.625x95.5.pdf Approved for use outside HVHZ:Yes I Quality Assurance Contract Expiration Date Impact Resistant:No i 06/16/2018 Design Pressure:+50/-50 Installation Instructions Other: FL10976 R6 II PAV_SPD NCTL210-3576-4.pdf Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports FL10976 R6 AE PER3044.pdf Created by Independent Third Party:Yes 10976.2 Premium Atlantic Vinyl j Packet Sliding Patio Door(3800) 190.125"x 95.5"Insulated Glass(3/16"-3/16"Tempered)(Safety Glazing) Limits of Use 1 Certification Agency Certificate Approved for use in HVHZ: No FL10976 R6 C CAC XXXX LC-PG50-190.125x95.5.vdf Approved for use outside HVHZ:Yes (Quality Assurance Contract Expiration Date Impact Resistant:No 06/16/2018 Design Pressure:+50/-50 Installation Instructions Other: 1 FL10976 R6 I1 PAV SPD NCTL210-3576-3.pdf Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports I FL10976 R6 AE PER3045.pdf Created by Independent Third Party:Yes Back Next contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® eYI-F M 2 of 2 01/31/2017 10:02 AM � a AAMA (Validator/Operations Administrator) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION JELD-WEN Windows&Doors P.O.Box 1329 Klamath Falls,OR 97601 Attn: Jason Kantola The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests,and the reporting to the Administrator of the results of tests,accompanied by related drawings, by an AAMA Accredited Laboratory. 1.The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION AAMANVDMA/CSA 101/I.S.2/A440-08 RECORD OF PRODUCT TESTED LC-PG50-4841x2428(191x%6 SD COMPANY AND CODE CPD NO. SERIES MODEL&PRODUCT MAXIMUM SIZE TESTED DESCRIPTION PREMIUM ATLANTIC VINYL FRAME SASH JELD-WEN Windows&Doors BYPASS SGD Code:JW 3557 (pVC)(OXXX)(OG)(INS GL) 4841 mm x 2426 mm 1232 mm x 2359 mm (REINF)(ASTM) (15'11"x 8'0") (4'1"x 7'9") 2.This Certification will expire June 16,2018(extended from June 16,2015 per AAMA 103-14a)and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3.Product Tested and Reported by: National Certified Testing Laboratories Report No.: 210-3576-3 Date of Report: June 23,2009 Validated for Certification h, A--'iL A oci ted Laboratories,Inc. Date: April 14,2015 Authorized for Certification Cc: AAMA JGS T ACP-04 (Rev.1/11) AmedcWArchitectural Manufacturers Association 11/2"MM EMBEDMENT NAIL FIN INSTALLATION MDV.DISTANCE OPTIONAL FROM EDGE:3/4'. 2 BOTH scREWS MIN.DISTANCE 1/2'MM FROM EDGE:3/4' �Ehk`.EbMENT 1 1/2"MIN. 1/4"MAX 18" O.C. MAX. 5' MAX. 2%WOOD FRAME EMBEDMENT SHIM SPACE THRU FRAME, FROM FIN OPTIONAL s� MIN.DISTANCE 3 Q p ORNERS LRJ4 FROM EDGE:3/4°, 17" O.C. BOTH SCREWS MAX. FRFINE, 2X WOOD FRAME ❑ l=5 OPTIONAL l a i Izs 4mm 41— 4.7m" 11/2"MIN. DOW 99S EMBEDMENT I suss SITE W I 20.6w4 I OPTIONAL 2 I�ry -------------- G i MIN.DD GE:ANCE 3/4 I.�a L 1 GLAIING DETAIL FROM EDGE:3/4° WOOD FRAME SECTION(TYP) ' FRAME SECTION MP) HORIZONTAL SECTION VERTICAL SECTION NOTE:T Tk Delrnen MWN Flo 6Wood Op.9. I ^u00R WIDTH (190 5/8' MAX.) 1 "°gym^°^-�^�•°+••-^°°+ TYPICAL ELEVATION WITH FASTENER 5PACING TWO,THREE AND FOUR PANEL '/4'MAX SPACONFIGURATIONS APPROVED 514 2x wOODoe FRAME AME MM DISTANCE 11/2'MM FROM EDGE:3/4' 3 PARED MDQ DISTANCEMax Frame DP RATING IMPACT OPTIONAL ' . HEDGE.)/`'' 190 5/8" x 951/2" +50/-50 NO ROTHBOTSCREWS 11/2'MIN.EMBEDMENT Installation Notes: General Notes: 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of 2. Use#10 PH or greater fastener through the nail fin with sufficient length to penetrate a minimum of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida 11/2"into the wood framing. For 2x wood frame substrate(min.S.G.=0.42). Building Code(FBC)and the industry requirements for the stated conditions. 3. Use(2)-#10 PH or greater fastener through the frame per location with sufficient length to penetrate a 2. All glazing shall conform to ASTM E1300. minimum of 11/2"into the wood framing. For 2x wood frame substrate(min.S.G.=0.42). 3. At minimum,glazing is 4.7 mm tempered-16 mm airspace-4.7 mm tempered glass. 4. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 4. Use structural or composite shims where required. to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Digitally signed by Hermes F.Norero,P.E. This schedule addresses only the fasteners required to anchor the Reason:I am apprQ�uttlis jgcflnEnt window to achieve the rated design pressure up to the size limitations Date:2014.0. M: °2 0 ' noted. It is not intended as a guide to the installation process and does �% PROJECT ENGINEER: DATE: ` ••••• •• JELDVEN Klamath F Lakeport Blvd not address the sealing consideration that may arise in different wall �� Q ,.• F �� -- 08/1H/2014 conditions. For the complete installation procedure,see the instructions ��: �,� •'.�� DRAWN BY: scALE: Klamath Falls,OR.97601 packaged with the window or go to 7 D.Vezo Phone: (541)882-3451 www.jeld-wen.com/resources/installation. _ * * _ CHECKED BY: TITLE:J. Kantola DISCLAIMER: = -0 T T Q = APPROVED BY: Premium Atlantic Vinyl Sliding Patio Door 0X)0( This drawing and its contents are confidential and are not to be % O ••'� 0 DP:• �: P T P O r reproduced or copied in whole or in part or used or disclosed to others s 141, a. a. 4Nelo 8% ,� �M�M� l except as authorized by JELD-WEN Inc. � �° �° 888 IDENTIFIER No. 576- PLANT ANLOCATION: L e FL: CAD DWG.NO.: REV: oo SHEET S OF4 THROUGH FRAME MIN.DISTANCE INSTALLATION FROM EDGE:3/4' 2 Z 1 I/2'MM � EMBEDMENT 11/2'MIN. 1/4°MAX 5" MAX. Q ❑ 1/4'MAX EMBEDMENT SHIM SPACE 18" O.C. MAX. FROM SHIM SPACE THRU FRAME 'CORNERS r p MIN.DISTANCE 1 FROM EDGE:3/4° > 17" D.C. MAX. ❑ � THRU 1 2 F3 "N FRAME i 3 no I1 IL JI 27.4.7 N i 4.7mm 4.7mm v i DOW 994 4 MIN.DISTANCE 2 C=7 i x'20.6- FROM EDGE:3/4° o0 a - -------------- a O O f i GLAZING DETAIL 1 LFRAME SECTION(TVP) FRAME JAMB SECTION(TYP) uDOOR WIDTH (190 5/8" MAX.) VERTICAL SECTION HORIZONTAL SECTION TYPICAL ELEVATION WITH FASTENER SPACING TWO,THREE AND FOUR PANEL 1/4"MAX CONFIGURATIONS APPROVED 0 C' SHSPACE SPACE MBEDMENT Max Frame I DP RATING IMPACT MIN.DISTANCE• 3 190 5/8" x 951/2"1 +50/-50 J NO FROM EDGE:]q' Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of 2. Use(2)-#10 PH or greater fastener through the frame per location with sufficient length to penetrate a the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum of 11/2"into the wood framing. For 2x wood frame substrate(min.S.G.=0.42). Building Code(FBC)and the industry requirements for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 4.7 mm tempered-16 mm airspace-4.7 mm tempered glass. project of installation. 4. Use structural or composite shims where required. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER: DATE: ,• •• iEL,�N 3737 Lakeport Blvd not address the sealing consideration that may arise indifferent wall 08/12/2014 conditions. For the complete installation procedure,seethe instructions ��;'�,� �� DRAwN BY: scALE: Klamath Falls,OR.97601 packaged with the window or go to 7 D.Vezo NTS Phone: (541)882-3451 CHECKED BY: TIRE: www.jeld-wen.com/resources/installation. _ * * _ J. Kantola DISCLAIMER: -° T T G= = APPROVED BY: Premium Atlantic Vinyl Sliding Patio Door 0X)0( This drawing and its contents are confidential and are not to be ���••'•. L DP ���� P T P 0 E rs� 64 reproduced or copied in whole or in part or used or disclosed to others N;�b' a ��` �bi� �l3 except as authorized by JELD-WEN Inc. s88 ase INGTL210-3576-EMBANVenice FL: CAD DWG.No.: REV: oo SHEET 20F4 MMDISTANCE MMDISTANCE MASONRY INSTALLATION FROM EDGE:2 Ur FAOM ENS 2 Vr • • MASONiY .. • •• BIS • s e. 1 V,•MM EM6EOMEM 7 B" O.C. MAX. 5" MAX. t FROM 1 va•MIN v4•MAX THRU FRAME-�-t-r ORNERS ❑ w•MAx EMBEDMENT 5HIM5PACE 5N[M SPACE MIN.DxsTANOE a �' � 1# 4 1# 4 17" 0•C•MAX. FROM EDGE:2 V2• gr ' THRU FRAME I 2 'e ❑ �' � I 26A". ,.I•m 4.— .. Dow sys 6 Damn MIN.DISTANCE 2•'• FROM ED6E:21/2' Q � • W = I ----------- I K 0 I BLOCK RAME Jt o I GLAZING DETAIL FAMB SECTION(TYP) L I FRAME SECTION(TYP) HORIZONTAL SECTION VERTICAL SECTION ,.,,vw......w-w : DOOR WIDTH (190 5/9" MAX.) I TYPICAL ELEVATION WITH FASTENER SPACING 0 TWO,THREE AND FOUR PANEL p 1/. SHVASP SPACE CONFIGURATIONS APPROVED • G( ? 2 1V,•MM d :•. •• 4 � EMBEDMENT •: Max Frame DP RATING IMPACT MM DISTA" 190 5/8° x 951/2" +50/-50 NO MIN.DISTANCE l NT FROM ED6E:2 VT FROM ED6E:21/Y Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of 2. Use(2)-3/16"Tapcon or equivalent fasteners through frame per location with sufficient length to the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida penetrate a minimum of 11/4"into concrete or masonry ar each location with a 2112"min.distance Building Code(FBC)and the industry requirements for the stated conditions. from the edge. For concrete(min.fc=3000 psi)or masonry substrate(CMU shall conform to ASTM 2. All glazing shall conform to ASTM E1300. C90). 3. At minimum,glazing is 4.7 mm tempered-16 mm airspace-4.7 mm tempered glass. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 4. Use structural or composite shims where required. to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does �V PROJECT ENGINEER: DATE: •..•• •. i 3737 Lakeport Blvd not address the sealingconsideration that may arise in different wall .• -- 08/12/2014 conditions. For the complete installation procedure,see the instructions :�� '�,� •' �� i DRAWN BY: SCALE: JELEMENKlamath Falls,OR.97601 packaged with the window or go to 7 D.Vezo NTS Phone: (541)882-3451 www.jeld-wen,comlresourcesfinstallation. _ * * _ CHECKED BY: TITLE:J. Kantola DISCLAIMER: C = APPROVED BY: Premium Atlantic Vinyl Sliding Patio Door 0X)0( This drawing and its contents are confidential and are not to be %�C ••••. 4.0 OrP•'•���., : PA�RRT P 0 E�r D reproduced or copied in whole or in part or used or disclosed to others ��i tin VJV k0 a *- U6� U except as authorized by JELD-WEN Inc, BOB AHOat � 999 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET p bYY�� NCTL210-3576- -FBC Venice, FL 00 3OF4 MRI DISTANCE MIN,DISTANCE MASONRY INSTALLATION FROM EDGE,2 Vr FROM EDGE.2 Vr • • MAGOMY ' • GLOC[ •• A y e- 1 v.•MM EMREDMEM 1B" O.C. MAX. 5" MAX. t FROM 1 va°MIN. 1/4 MAX THRU FRAME t-1 ' ORNERS w•MU �ED'"E"T SMM SPACE SHIM WOE r(/ 7" O.C. MM DISTANCE �1I MAX. FROM EDGE:z yr0. THRU ❑ FRAME 1 2 '• F� Vm"- 4.7- 1 DDw GGs � n MIN F.222=21' V 2 ' Q '° • W 1 in GL i AZING DETAIL BL= FRAME JAMB SECTION(TYP) L FRAME SECTION nvP) HORIZONTAL SECTION VERTICAL SECTION DOOR WIDTH (190 5/8" MAX.) I TYPICAL ELEVATION WITH FASTENER SPACING 0 TWO,THREE AND FOUR PANEL p 1HA SXIM2MSPACE CONFIGURATIONS APPROVED t • i t.. 11/4-MM • d : '• t � EMDEDMEM •: Max Frame N RATING IMPACT ""GD`•T190 5/8" x 95 1/2" +50/-50 NO BLOC% MM NSTANCE MM DISTANCE FROM EDGD 2 VT FROM EDGE:2 ur Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of 2. Use(2)-3/16"Tapcon or equivalent fasteners through frame per location with sufficient length to the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida penetrate a minimum of 11/4"into concrete or masonry ar each location with a 21/2"min.distance Building Code(FBC)and the industry requirements for the stated conditions. from the edge. For concrete(min.f =3000 psi)or masonry substrate(CMU shall conform to ASTM 2. All glazing shall conform to ASTM E1300. C90). 3. At minimum,glazing is 4.7 mm tempered-16 mm airspace-4.7 mm tempered glass. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 4. Use structural or composite shims where required. to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does �V ,� PROJECT ENGINEER: DATE: ` ••••• •• • ' JELDVEN 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall �� Q' ,.F (�` �� -- 08/12/2014 conditions. For the complete installation procedure,see the instructions : ��;' '.�� DRAWN BY: SCALE: Klamath Falls,OR.97601 packaged with the window or go to ; D.Vezo NTS Phone: (541)882-3451 .. CHECKED BY: TITLE: www.jeld-wen.com/resources/installation. _ * * = J. Kantola DISCLAIMER: = "� T T 4 = APPROVED BY: Premium Atlantic Vinyl Sliding Patio Door 0X)0( -A •• This drawing and its contents are confidential and are not to be %0 •• �0 reproduced or copied in whole or in part or used or disclosed to others i� " "''�6 i�a except as authorized by JELD-WEN Inc, a _—�Y� 998 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET Oi NCTL210-3576- -FBC Venice, FL 00 30F4 STEEL INSTALLATION I MIN.D2S7A FROM EDGE:1/2 1/2' 3 2 2 Mia rmbedm t of throe thrrcda Pvt frame la gaugemin Min.embedment 1/4"MAX 5' MAX. C11 0 12 steel stud of three threads SHIM SPACE 18' O.C. MAX. FROMPact frame THRU FRAME 1/4'MAX _ 1117 NERsSHIM SPACE MIN.DISTANCE" 0.C. FROM EDGE:1/2" Ll I: MAX. THRU e FRAME Q� \ I 25.4— IS gauge min 3 Steel Stud 4.7mm4.7 -F-F�-.-� 4.7-10 I I 1 ' v I DOW 995 F � Z MIN.DISTANCE 2 W = i SS BnE sL20.enun FROM EDGE:1/2" se= ' Q -------------- 0 d� 0 i � � GLAZING DETAIL � L FRAME SECTION(TVP) FRAME JAMB SECTION(TYP) I DOOR WIDTH (190 5/8' MAX.) � vERTtcah sEcrloN HORIZONTAL SECTION .ae .,.e,,a•. TYPICAL ELEVATION WITH FASTENER SPACING TWO,THREE AND FOUR PANEL 0 0 CONFIGURATIONS APPROVED Q I/4^MAX SVQM SPACE Is gouge m1n 3 2 2 sled shd Max Frame I DP RATING IMPACT AUX°DG: ft Mh.* .d 190 5/8" x 95 1/2" 50/-50 NO FROM EDGE: f than tluead. + Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of 2. For anchoring into metal framing,use(2)-#10 TEK Self Tapping screws per location with sufficient the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida length to achieve a minimum embedment of three threads past the frame thickness. Locate anchors as Building Code(FBC)and the industry requirements for the stated conditions. shown in elevations and installation details. Steel substrate min.18 ga(fy=33 ksi). 2. All glazing shall conform to ASTM El 300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing is 4.7 mm tempered-16 mm airspace-4.7 mm tempered glass. to the structure. The host structure is the responsibility of the architect or engineer of record for the 4. Use structural or composite shims where required. project of installation. This schedule addresses only the fasteners required to anchor the ,,1 window to achieve the rated design pressure up to the size limitations ��� noted. At— It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE: not address the sealing consideration that may arise in different wall ��� ,.••' �` �i� -- . 08/12/2014 JEL13rWENKlarriath3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions � ;'�,� • O D VeY: SCALE. NTS PhoneFalls,OR.97601 packaged with the window or go to (541)882-3451 www.jeld-wen.com/resourcesriinstallation. _ * — CIiECKi TIRE: J. Kantola DISCLAIMER: = -� T T ; = APPROVED BY: Premium Atlantic Vinyl Sliding Patio Door 0X)0( This drawing and its contents are confidential and are not to be %� •'• `�: P�ar,(PboE�r�f reproduced or copied in whole or in part or used or disclosed to others 998 a�,�t 998 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEEP except as authorized byJELD-WEN Inc. "� L �-r NCTL210-3— -FBC Venice, FL 00 4OF4