HomeMy WebLinkAboutNotice of Acceptance i I MIAMI-DADS COUNTY M_ IAMMADE i PRODUCTiCONTROL SECTION 11805 SW 26 Street_ Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2,17,1 BOARD AND CODE ADMINISTRATiON DIVISION T(786)315-25901:(79(-,)315-2599 NOTICE OTIC OF ACCEPTANCE (NOA) \S'1Y\Y.I711;1111111a111'.t!1�1'�CCIIIIUIII�' 1 I GAF I Campus Drive i Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the.use of construction materials.'file documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority 1-lavin�.lurisdiction This NOA shall not be valid after the expiration date stated below. The Miami-Dade County iProduct Control Section (in Mianli Dade County) and/or the Ai-1J (in areas other than Miami Dade County) reserve the tight to have this product or material tested for quality assurance purposes. If this product or material ('arils to perform in the accepted manner, the manufacturer will incur the expense of such testing and the Al-IJ nlay immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RLR reserves the right to revolve this acceptance, if it is determined by Mianli-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity i-lurricane Zone of the Florida Building Code, DrSCi21P'I'iONs( AA[ Tu»`b�Tlirje�hd:D"",Timberline Natural Shadow°",and 'timberline American Hat-vest"" Shingles L.AS➢r,LiNG: Each unit shall bear a permanent label with the manufacturer's name or logo, city,'state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. I RENEWAL of this NOA shall be considered after a renewal application has been tiled and there has been no change in the applicable building code negatively affecting the performance ofthis product. TERMINATION of this NOA will occur after the expiratioti date or if there has been a revisiotp or change in the materials, use, and/or tllanuleacture of the product or process. Misuse of this NOA,as illi endorsclilent of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. failure to comply with any section oFthis NOA shall be cause for termination and removal ol'NOA. ADVERTISEMENT: The NOA number preceded by the words Mianli-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages I through 6. The submitted documentation was reviewed by Juan E. Collao, R.A. I NOA No.: 14-1022.20 MIAMI-DADE COUNryo Expiration Date: 02/21/17 low Approval Date: 02/05/15 i Page I of 6 'I � P iI I ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Cateuory: Asphalt Shingles Materials: Lanlinatc i Deck Tyne: Wood SCOPE This approves GAF Timberline MY%Timberline Natural Shadow",and Timbl rline American harvest"" Shingles as manufactured by GAF as described in Section 2 of this Notice of Acecl'ptance, PRODUCT'DESCRIPTION Product Dimensions Test Product DCscription Specifications GAF imberlhlcll,D, 13 '/,,"x 39'/s" TAS 110 Fiberglas s rcinf orced I1cavy weight asphalt Mangfticluring roofshiii ,le, with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline Natural 13 '/,, x 39'/8' TAS 110 Fiberglass reinforced heavy weight asphalt Shadow"` roof shingle, widi a laminate profile ,ldunnfbcttn•in�g Locations#1,2,3,4,5,6,7 GAF Timberline American 13 'I,,"x 39}/8 TAS 110 Fiberglass reinforced heavy weight asphalt harvest", roof shil'1gle, with a laminate profile Arluntifacttn•in�,= + Locutions#2,4,5,6 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, M 3. Baltimore, MD 4. Myerstown, PA 5. Ennis,TX 6. Tuscaloosa, AL j 7. Dallas,TX � I r MIAMi•DADE COUNTY NOA No.: 14-1022.20 • ► Expiration Dalc: 02/21/17 Approval Date:02/05/15 Page 2 of 6 I i ! 1 , I aT I EVIDENcr SUBMITTED Test Alieney Test Identifier Test Nance/Reyort Date Underwriters Laboratories, Inc. ASTM D3462 I ICA48924 10/211/11 Underwriters Laboratories, Inc ASTM D3462 I OCA21994 04/22/11 Underwriters Laboratories, Inc ASTM D3462 IOCA28717 07/26/11 Underwriters Laboratories, lnc. ASTM D3462 05CA,17541 I I/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA 31580 11/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt.Technologies, Ina ASTM D3462 GAP-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 09/11/02 Underwriters Laboratories, Inc. ASTM D3462 03NIC26444 10/17/03 Center for Applied 6nginecring ASTM D3462 257989 05/13/97 Underwriters Laboratories, Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories, Inc. TAS 107 65CA42840 1 1/1 1/05 Underwriters Laboratories, Inc. TAS 107 62NK4181 1 1 1./1 1/02 Underwriters Laboratories, Inc. TAS 107 1..03CA35209 10/17/03 Underwriters Laboratories, Inc. TAS 107 1 04CA 13850 08/30/04 Center Im Applied Engineering TAS 100 1 257989 04/01/97 PRI Asphalt Tcchnolooies. Inc. TAS 100 GAF-0244=02-01 01/13/04 PRI Asphalt Technologies, Inc, rAS 100 GAP-098-02-01 11/08/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-101-02-01, 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAP-1 16-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01- 10/16/02 ELK-084-02-01' 10/15/02 ELK-085-02-01 10/14/02 ELIC-086-02-01' 10/24/02 EL,K-087-02-01 10/21/02 EL.K-088-02-01 10/16/02 ELK-107-02-01 10/09/03 13LK-108-02-01 10/09/03 ELK-109-02-0 I 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for lire ratings of this product. 2. Shall not be installed on roof wean heights in excess of 33 ft. ; 3. All products listed herein shall have a quality assurance audit In accordance with the Florida Building Code and Rule 61G'0-3 ofthe Florida Administrative Code. NOA No.: 14-1022.20 QM1 •DADECOUNTY Expiration Date: 02/21/17 ...� Approval nate: 02/05/15 Page 3 of 6 at I INSTALLATION 1. Shingles shall be installed in compliance with Rooting Application Standard RAS I"15. 2. Flashing shall be in accordance with Rooting Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W, attached. 5. Nailing shall be in compliance with Detail U, attached. LABELING Shingles shall bear the Imprint or identifiable marking of the manufacturer's name or logo, city and state of nianUf1etU1'►I1g facility, and following statement: "Miami-Dade County Product Control Approved" or the Mianli-Dade County Product Control Seal as shown below. CMIAMI-DADECOUONTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the iipplicabl'e code in order to properly evaluate the installation of this system. 1 NOA No.: 14-1022.20 MIAMI•DADECOUNTY ' Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 4 of 6 f d DETAIL A , COURSE LAYOUT f ' DECK r i I FULL I � I 5th 17"OFF 4th I 11" OFF 3,rd f ' 6" OFF 2nd FULL 1st I 3 i Y MIAMI•DADE COUNTY ! NOA No.: 14-1022.20 Fligm , Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 5 of 6 i 17 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/811 141/2"-17-112" 14-1/2"-17-1t2" (168-445mni) (368.445mm) go 6-1/2"-9-1/2" ail guide line 6-1/2"-9-1/2" -3/4"-6-1/4" 1 37j A '5� nim) (146mm-159mm) 112'•2-72" (13-64 — from bottom of shingle Self seal adhesive on back ENHANCED NAILING PATTERN six nails per shingle* required by some local nodes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (1 52mm)from bottom,of of shingle, above the cut outs, as shown. Nails must not be'exposed, END OF THIS ACCEPTANCE I [MIAMI-E NOA No.: 14-1022.20 DUMP RMF Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 6 of 6 I Florida Building Code Online i j Page 1 of 2 > y F;• � �A`� r C' 4;iti ,} � yr i ry�, I ` �,. �� AI Yf( ���I � $n`r�A�+lf: :�. ✓,'. 4Fr 'Ir` _ I / �'� �, r BCIS Home Log In i User Registration Hot Topics Submit Surcharge Stats B Facts Publications I FBC Staff BcIS Site Map Links search b Florida at i�:! ProductApproval pr ylsl P0�USER:Public User Protect Approval llenu>Product or Aoolica Uon Search>Application Lis l>Application Detail r� �s•�x*.rz' �r� fr[rf z7's' FL# FL16048-R4 Application Type Revision f\ Code Version 2014 Application Status Approved �� 1 Comments ✓ Archived ❑ b Product Manufacturer Tri-Built Materials Group,LLC Address/Phone/Email PO Box 70 Y Rutherford,NJ 07070 (800)516-1485 david.ruiz@tribuiltmg.com Authorized Signature David Ruiz david.ruiz@tribuiltmg,corn Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford, NJ 07073 (201)842-2449 david.ruiz@tribuiltmaterialsgroup.com I I Quality Assurance Representative Address/Phone/Email I I I Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered{Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen j the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W. Knezevich,PE i fel Validation Checklist Hardcopy Received Certificate of Independence FL16048 R4 C01 2016' 01 COI Nieminen.odf i Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM G155 2005 FRSA/TRI April 2012(04-12) 2012 TAS 103 1995 Equivalence of Product Standards Certified By I Sections from the Code http://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQWtDgtFPmdYiND Wr... 1/26/2017 T lorida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D I Date Submitted 10/06/2016 Date Validated 10/17/2016 Date Pending FBC Approval 10/19/2016 Date Approved 12/13/2016 i Summary of Products FL# Model,Number or Name Description 16048.1 TRI-BUILT Roof Underlayments Self-adhering,modified bitumen ro6f underlayments Limits of Use Installation Instructions Approved for use in HVHZ:No FL16048 R4 1I 2016 10 FINAL ER TRI- Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R4.Odf Impact Resistant:N/A Verified By: R6bert Nieminen PE-59166 Design Pressure:+N/A/-67.5 Created by Independent Third Party:Yes Other: 1.)The design pressure noted herein pertains to use Evaluation Reports of foam-on tile systems overtop the self-adhering FL16048 R4 AE 2016 10 FINAL,ER TRI- underlayment for one particular application.See ER Section BUILT UNDERLAYMENTS 1`1_16048'R4.Odf 5.6.4 for details.2.)Refer to ER Section 5 for other Limits of Created by Independent-Third Party: Yes Use. I Back Next f I Contact Us::2601 Blair Stone Road.Tallahassee R 32399 Phone:850.487-1824 i The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the.office by phone or by traditional mall.If you haveiany questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here Product Approval Accepts: �IVCI Credit Card ; Safe w i i _I I http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr... 1/26/2017 i (EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY 353 CHRISTIAN STREET, UNIT QOERD OXFORD,CT 06478478 PHONE: (203) 262-9245 FAX:(203).262-9243 EVALUATION REPORT Allied Building Products Corp. Evaluation Report A42960_10.12-R4 dba TRI-BUILT Roofing Products FL16048-R4 9050 Louisiana Street Date oflIssuance:10/25/2012 Merrillville, IN 46410 Revision 4: 10J06/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rulesWd regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 51h'Edition (2014)!Florida Building Code sections noted herein. j DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate.to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify; Robert'Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity 11ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle,. ' ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall-be provided to the user"by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: �,>t!!t�fr!r•r,,,— •�•4�5�"'•a"C�-��CThe facsimile seal appearing was authorized by.Robert Nieminen, Robert J.M.Nieminen,P.E. i• uP,E.on10/06/2016.This does not same as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 �. document.Signed,sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: I 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. i i 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nleminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. I I i I4T---R INI TY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: i Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard'j Year 1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1570 2009 1507.4.5.1,1507.5.3,1507,7.3 1504.6 Accelerated Weathering ASTM G155 2005 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6.5.2.1 Physical Properties TA5 103 i 1995 3. REFERENCES: I Entity Examination Reference Date ERD(TST6049) Physical Properties S40540.02:13-1 02/19/2013 ERD(TST6049) Physical Properties S40540.11.13 11/19/2013 ERD(TST6049) Physical Properties S40540.03.14 03/26/2014 ERD(TST6049) Physical Properties S44870.04'.14-2 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties 544870.0,4.14-4 04/10/2014 ERD(TST6049) Physical Properties S43530.02.14-1-111 05/14/2014 ERD(TST6049) Physical Properties 543530.0;5.14 05/28/2014 ERD(TST6049) Physical Properties 540540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 UL,LLC.(QUA9625) Quality Control Multiple,6sting R16814 J 09/04/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering:Underlayments: i 4.1.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering,,,glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced,.SBS modified bitumen roof underlayment 4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, (glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment. i S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E, are, in any way, the Designer of Record for any project on which this Evaluation Report, or previouls versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. j 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. I Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R4 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL16048-R4 Revision 4:10/06/2016 j Page 2 of 5 R � y I ' TRINI-ry ERD I 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover Iwhere the product is specifically referenced within FBC approval documents. If not listed,a request may made to the AHJ for approval based on this evaluation combined with supporting data.for the prepared roof covering- 5.5 Allowable roof covers applied atop the underlayments are as follows: TABLE 1:'ROOF COVER'OPTIUNS a , Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri-Built S/A HT TU Yes Underlayment Yes Yes See S.S. Yes Yes Yes Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless)tensile adhesion / long term aging data from an accredited testing laboratory is provided.; 1 ➢ Tri-Built S/A HT TU Underlayment with 3M` 2-Components Roof Tile Adhesive AH-160 (FL6332) or Dow TileBond'"Roof Tile Adhesive(FL717) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or1ri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates,'TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 241hours. Note: TRI-BUILT requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or,Tri-Bulit Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a.qualified design professional and installed based'on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS.114,Appendix J. 5.6.3 Bond to Mechanically Attached Base Layer: Tri-Built Sand'R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type I or 11 felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-114 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL16048-114 Revision 4:10/06/2016 Page 3 of 5 i � I TRIN11Y ERD 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 201-2 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam,-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to d.irect-deck underlayment systems that are not addressed in FRSA/TRI April 2012(04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6.4.1 Maximum Design Pressure=-45.0 psf. Deck: Min.15/327inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf. Deck: Structural concrete to meet project requirements to satisfactionlof AHJ. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.6.4.3 Maximum Design Pressure=-60.0 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps'and 6-inch o.c.in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.7 Exposure Limitations: 5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth�HT S/A Underlayment,shall not be left exposed for longer than 30-days after installation 5.7.2 Tri-Built S/A HTTU Underlayment shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any-loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any.dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or.Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile applications: While priming is optional,TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as'far as possible. Once the entire length of membrane is In place, peel-off the release.film diagonally while holding the membrane tight. Firmly roll,broom or hand-press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below,(sealed in accordance with TRI-BUILT requirements. Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R4 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL16048-R4 Revision 4:10/06/2016 Page 4 of 5 TRINITY ERD When installing at slopes above 8:12,TRI-BUILT recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.'Peel the release,paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and,work upward. 6.3.3 Tile Applications(Tri-Built S/A HTTU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents; tile slippage and/or damage to the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: ! i Contact the noted QA agency for information on product locations covered.for F.A.C.Rule 9N-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625;(314)578-3406;Ic.chancellor@us.ul.com END OF EVALUATION REPORT- i I i Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R4 Certificate of Authorization#9503 FBC NONMVHZ EVALUATION F1.16048-114 Revision 4:10/06/2016 Page 5 of 5 1 i i