Loading...
HomeMy WebLinkAboutProduct Approval : C 1 v _ ..e ES4IS Name Log in User Reg+stration Hct Toptcs Sutrntd 5urrturge Stats:t r'act. r t:t.f:r,stum�. F5f_Start MIS 5!e t•'a:s ti^<; "'f3'.D Business/,: Product Approval � a_ Professi O' ' }o s1t♦ 1>rfxt,ry;.lrrunri+i S�eme,+Neczciuft 2�r 0.ppl+ra+lion St-.trct>>hpCriC tiAn t Application Detail FL# FL10674-R12 Application Type Revision Code Version 2014 Application Status Approved "Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.coatn Technical Representative Mel Sancrant Address/Phone/Email i Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mei,sancrant@owenscornig,com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert 3.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By Sohn W. Knezevich, PE •'' Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R12 C01 2016 Q1_,C:OI Nrennnen.Df Referenced Standard and Year(of Standard) Standard year ASTM D3161 2.009 ASTM D3462 2009 ASTM D71S8 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option,D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FOC Approval 04/20/2016 Date Approved 06/08/2016 Summary of Products FL# Model,Number or Name Description 10674.1 j Owens Corning Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, starter and hip&ridge i Shingles and Starters Shingles I'Limits of Use ;Installation Instructions { Approved for use in HVHZ: No FL10674 R12 R 2016_24 FINAL ER OC. ASPIInI,T Approved for use outside HVHZ:Yes zHiNtE, Sit)67a-R12. df Impact Resistant:N/A ! Verified By: Robert J. M. Nieminen PE- 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other:Refer to ER, Section 5. 1 Evaluation Reports FL,1074 Rl2 AE 2016 04 FINAL FR OC- ASPIiALT i_$j_UNQl FS.LLq674-RL2 odf -- Created by independent Third Party: Yes C.ontart tis:: 941 0 North,Monroe Street.Tallahassee fl 32399 Phone,;$50-487-1624 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::privacy Stalemt,nK:: Arressibility Statement::Refund Statement Under Florida law,email addresses are public records,if you do not want your a-mait address released in response to a public-records request,du net send electronic mail to this entity.Instead,contact the office by phone or by lydditiunal mail.If you have any questions,ploase contact 650.487.1395. `pursuant to Section 455.275(1),Florida Statutes,effective October t,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email autirest:if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record. If you do not Wish to t.upply a personal address,please provide the Department with an count address which can be made available to the public.To detetmine if you are a irrc,"ee under Cha,^,ter 455,F.S.,please dick here. Product Approval Accepts: vcurit ear r 1-r=rr GOO- , EXTERIOR RESEARCH QDESIGN, LLC. / cc��c uo/x,mo"zvov :mu ' 353CHRISTIAN STREET,UNIT 9I3 ERD OXFORD,{T Ud478TRUUN U 1 . ' PHONE:(ZO3) Z62-9Zx5 FAX:(2D3)262-9Z4] EVALUATION REPORT Owens Corning Evaluation Report O3794O.VZ.1%'R7 n�Z One Owens Corning Parkway Fi10674' Toledo,OH4]G59 Date ofIssuance*U2/O6/zU12 Revision 7- 84/18/2016 Scops: This Evaluation Report bissued under Rule 61G20-3 and the applicable rules and regulations governing the LISP Of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the S* Edition (2014) Florida Building Code sections noted herein. DcscmpTmm: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CoMT|wusD COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes' or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Tr|nityJEAD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. |fany portion ofthe Evaluation Report|sdisplayed,then itshall bedone inits endrecy. INSPECTION: Upon request, a copy ofthis entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists afpages lthrough 8. Prepared by: OF The facsimile seal=,^^^.^~°.".*"."ed^,,^w'.v'^,",=' Robert J.K8. Nieminen,P.E. p�E,�ov,wmo ,w*==°"°°"".+.=.^`"�"w~ rmm�xe«�onmmm�eo6�nnmmOCA xw�yxa `/^^'''"'``' �cu"wn`5we^°~* ^"���w��=,°°°m°..~" Product^wrovm^m"m^.".","nd`"*""am~ m".. CERTIFICATION o,INDEPENDENCE: z. Thnitv|ExD doe* not have, nor does it intend to acquire or will it acquire, a hoondx{ interest in any company monufdcm,in« or distributing products bevaluates. 2. mn|m|snounot owned,operated or controlled by any company manufacturing or distributing products it evaluates. a. Robert Nierninen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert miemincn, Pf.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of tile product. s. This i, a building code evaluation. meithe,mnnv|Enm nn, Robert m|umi^on, P.E. ire, in any way, ,he Designer of necu/o for onv project on which this Evaluation Report,u,previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. � ' �—�»��0—�� ��Fl ` TRINITY �-'`�� ROOFING SYSTEMS EVALUATION: 1. Scops/ Product Category* Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as.produced by Owens Corning, have demonstrated compliance with the following sections ofthe Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to,he Installation Requirements arid Limitations/Conditions ofUse set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM 03161 2009 1507.2,7.1,R905.2.6.1 Wind Resistance ASTM D7158 aoDo 3. RspEnEmcss: �n t Examination Reference Date oLLLC(ccK9626) Physicals&Wind Resistance File RZ453'Vol,a 02/I5/2007 uLLLC(C[R9a26) Physicals&Wind Resistance 20120516'112453 05/16/2012 uLLLC(TST90l8) Physical Properties 06Cx20263 04/18/1006 uLLLC(TsTyaIo) Wind Resistance 11C«34308 02/18//012 UiLLC(TsTyu28) Physicals&Wind Resistance 478609387 02x01/2014 ULLLC(7ST9om) ' Wind Resistance 4786126532 nz/zn/znz; ULLLC(T5T98ID) Physical Properties Classification letter 02/13/2014 UL Li[(ToT9s20) Physical Properties Classification letter 10/02/2015 kxiami'Dada(C[n15y2) ;aCxvHICompliance variousmo*u Various uLLLC (QUAy62s) Quality Control Service Confirmation,RZ4B sxp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic'and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tabasphalt roof shingles. 4.1.3 Devonshire"are fiberglass reinforced,5'tahasphalt roof shingles. 4.1.4 Duration*, TiuDefinidon^ Duration', Duration* Premium Cool, TroDeOnidon^ Duration' Designer Color Collection, Tru Definition'OakridUe^, Oakridge' and VVearher6uard^ HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire* Hip & Ridge ShinQ\es, High Ridge, VVea\herGuard~ HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shing|esandDumNdge=Hip&RidgeSbingiesarpfiberg|assre\nforced'hipundridgeasphdtroofshinA|es, 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. L/xx/r*nmms/ II This is a building code evaluation. NeitherTiinity|ERD nor Robert Niemioen' P.E. are, in any way, the Designer of Record for any project an which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report isnot for use inthe HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to CUrrent Approved Roofing Materials Directory- for8rerabngsofthispnoducc Exterior Research and Design,uc Evaluation Report n���.a2-m Certificate ofAuthorization vso Fu0674-1112 Revision 7:o*/z*m10 Page zv/u ' ` TRINITY ERF 5.4 Wind Classification: 5/L1 All Owens Corning shingles noted herein are Classified in accordance with FB[ Tables 1507l71 and R905l6.1 to ASTM D3I61, Class F and/or ASTM D7158' Class H' indicating the shingles are acceptable for use in all wind zones up to V°u= 150 mph (V,,,,= 194 mph). Refer roSection 6 for installation requirements tomeet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified inaccordance with FB[Tables 1507.2I1and R9D5.Z.G.1toASTM D3l61, Class F, indicating the shingles are acceptable for use in all wind zones UP to V11d=150 mph (V,,,,= 194 mph). Refer to Section 6 for installation requirements tomeet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category 8 or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions Outside these limitations. Contact the shingle manufacturer for data specific toeach shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. S.6 Ali products inthe roof assembly shall have quality assurance audit\n accordance with the Florida Building Code and F.A.[Rule 61GI0'3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Undedaymeni shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,o,beLocally Approved per Rule 61G2n']' per FB[Sections ISO7.23, 15O72.«orR9oS.2.3. 6.2 ' 6j.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FR[ Sections l5O7.Io/ K9O5.2, with the following exceptions: � Berkshire*shingles require minimum five(I)nails per shingle. � VVpathenGuard"HPshingles require minimum six(6)nails per shingle. � Devonshire"shingles require minimum six(G)nails per shingle. � Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FB[ 1507I.6o,R905l5. Staples are not permitted. 6.2,4 where the roof slope exceeds Zl units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Deck ser-ad!"ed Felt tinderlaymeni Deck Feb undedayment "Lack Weathe underjaymem DfiP_ Drip edg� Drip edge e louted located Install first Self-sealing adhesive WA first stinter Strip Sorter Stpig Positioned along cave ymh G'removed- shingle wit 6"removed Starter Strip shingle overhings eaves and rake5 V4"W' St.,tm Sn�p Plis"arfiang.ea,ol 311d,.ka�1A'-3W Exterior Research and Design,LLC. Evaluation Report���.12-m Certificate*«"m=*"tionp95m a10674'oI2 Revision 7.o^/m/2o1a Page 3v,u TRINITY ERD 6.2.6 Minimum Nailing—Classic-'&Supreme: r . r • . Normal Mansard or Area para Normal Mansard or Area pare Wind Areas High Wind desvanos y Wind Areas High Wind desvanes y Area para vienros normales Areas vlontoo fuertes Area para vienros normalos Areae vientos ruertas t (Al r r z' —(B) r2 t z" t•_ 5"Exposure 6 5!8•Exposure Exposition Expeaici6n 6.2.7 Minimum Nailing—Berkshire's: SnaOm s,rlp sealant strip La tiro de sn'kdor La tha de sellador A Va` a v?' a of a L2.. H W, 8+7" , r Standard Fastening Pattern 6-Nail Fastening Pattern S�ahnt snip La lira da sallador Ct• t.J , t♦����- ,rte X• Z" kphah rra lintt a?rtwnl Carmola do who da aslauu Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 CertiQcate oJAuthoriration#9503 FL10674-R12 Revision 7:04/18/2016 Page 4 of 8 TRINITY ERD 6.2.8 Minimum Nailing—Devonshire": 7" Nails 5.516•t:xpasere Sealant location Exposici6n de 5.518 PU19 Ubicaci6n del sellador .......... Ton Y'Spats of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—DurationO,TruDefinition Duration, Duration,' Premium Cool &TruDefinition Duration Designer Color Collection: 4-Nall Fastening Pattern 6-Nall Fastening Pattern S-W,m 1� 12- H.O.Typ.1 1 2' 12, Trp...l rt Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 S.WWW W, atm-psm� 1 `M1 �----- �----�Z jL. Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.L.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 F1.10674-R12 Revision 7:04/18/2016 Page 5 of 8 TRINITY ERD 6.2.1 Minimum Nailing—TruDefinitionxOakridge ,Oakridge"': 4 Nall Pattirn 6 Nail Pattom Esquoma coir 4 clavos Esquema can 6 clavos t t' r T f 4 6$WExposure Plaits SSf8'Exposure flails t Erposicicndo5610pulg. Claws Erposiaando55/spulg. 56'8"Exposure Clara 5518"Exposure Exposfcfdn do 5619pulg, Expoxicion dr 6 5/9putS. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for slopes Greater Than 21:12 ' Sv*RNuti Iitff6Ulo 8tt6 s+i.Sth N Il 1xry1 1 t i 1I '1 I Sl• �� i iwr r sp.a m a.tph."R—hog C.—M Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard°NP: Single We View Crow rn b tYnttr dw Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 certificate of Authorization#9503 F1.10674-1112 Revision 7:04/18/2016 Page 6 of 9 ^ / . . ' —��� ' X�]k—��� ���l @ ��Xx �U � � `-' ^�� 6.3 63.1 Installation of Berkshire* Hip and Ridge Shingles High Ridge VVeathe,Guord^ HP Hip and Ridge Shingles and ProEdge Hip& Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. installation nfDueR|dge" Hip & Ridge Shingles shall comply with the monvfacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation-limitations, including the use of hand-sealing for wind warranties. 63.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than F8C 1507.I6nrR905.2.5. Staples are not permitted. 6'3.3 Minimum Nailing—Gprksh|re*Hip&Ridge and High Ridge: Fig.2 6�.4 Minimum Nailing—VVeatherGuardl"MPHip and Ridge: Fig.A Fig.C Hip&Ridge Shingle Fastening galls Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 unVlcote ofx"thmnzatio"*sm FL10674-1112 Revision 7-.04/18/2016 Page rma � - ^ ' . ` ^ � ~�^C�U��X-�`w' ��F) � � ��H `�y i X �'`�^ 5.3.5 Minimum Nailing ProEdge Hip&NdgoShinglcs: Prevailing Standard Fastening Wind Direction Sohnt Strip Pattern Sealant Faslen 71P 6"Ex Cover E If Roof Cement 6.3.6 Minimum Nailing-DuraRid8e°Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer toOwens Corning published installation instructions fortheirm|nimum,equiements. 41 7. LAasuws: 7.1 Labeling shall be in accordance with the requirements the Accredited Owa|hy Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table l607.2.7.1/R905.2-61 8. BUILDING PERMIT RcQu|ms,wsmTs: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the named QAentity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC-QDA9626; (414)248'6409; - END OFEVALUATION REPORT' Exterior Research and Design,I.I.C. Evaluation Report oy/o^o.0zzz-R/ Certificate«yAuthorization xso r1.10674-1112 Revision r.o4/zu/mm Page uo/u „� .t-r ^^�. Tom'— , ria, m"fi � xr ."'� '�a �'Tr u-c'V b`L J't✓ -�'�"''3 tR 4qf x c` �.c' "5 r�� �.✓ i iif �'�t,r '� ri 1'ti 6� y,.Yr�cs�i � F1�,.,'}°�«,r� ��at46%. x� ���T^i �'.,. � iz i?-..i,��aA ..ae..�.� .. z,:a,ir.."•.,,,<,.oY�t»>�z'..^t',�.�.��aia�,. _�'fr-_''•�' BCIS€ioene : Log In User Registration Not Topics Submit Surcharge Stats a Facts Publications '. FBC Staff FICIS Site%4,10 Links Searc'* Business, E Product Approval Professibnal USER:Public User R c;uia_.ic,n Produrt Annrrval!401111>Prsxftirt or Ano€kation Saarch>srrpiii atiin fist>Application Detail WE, �� `� � � Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.kee)er@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underiayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden Validation Checklist- Hardcopy Received Certificate of Independence FL9777 R7 (t).i._.S3CLt4002,4A FBC ZOL4 Evaluation Replr;r WI,7tiierl�ck Non-HVH7 -flnal.ndf Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2009 ASTM G 155 2005 TAS 103 1995 UL 1897 2004 Equivalence of Product Standards Certified By Sections from the Code t ;r Product Approval Method Method I Option D Date Submitted 04/19/2016 Date Validated 04/20/2016 Date Pending FBC Approval 04/21/2016 Date Approved 06/08/2016 Summary of Products_ FL# _ Model,Number or Name Description V[9 1 ;Weatherlock G i Weatherproofing Underlayment Limits of Use i Installation Instructions Approved for use in HVHZ:No FL9777 R7 11 OCR14nt)2.4A FBC 2014 lyaluation RCp�rC j I Approved for use outside HVHZ:Yesteatt'rlock Non-HVHZ- final.Ddf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes 1 Other:See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002 4A FBC 2014 Evaluatign Re or Weatherlock Non-HVHZ- final.pdf Created by Independent Third Party: Yes ' 9777.2 }Weatherlock MAT Waterproofing Underlayment .._........-, Limits of Use I Installation Instructions Approved for use in HVHZ: No FI 9777 R7 11 OCR 111002.4A FBC 2014 Evaluation Reuol- Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-finaLodf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 x Design Pressure:N/A Created by Independent Third Party: Yes j Other:See evaluation report for limits of use. i Evaluation Reports E I FLQ777 R7 AE OCR14002 411 FBC 2014 Evaluation Reourt IIII y�e�tfterlock Non-HVHZ -finai.pdf i Created by Independent Third Party: Yes ; 9777.3 1 Weatherlock Metal Weatherproofing Underlayment _..._ _............__..____ Limits of Use Installation Instructions Approved for use in HVHZ: No f19777 R7 11 OCR,-}-0Q 4A FBC 2014 Evaittation 11=Dor Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ -final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports Ft 4777 R7 AE O RI4002 4A FBC 2014Ey luation Report Wherlack Non-HVHZ- final odf Created by Independent Third Party: Yes --l- 9777.4 Weatherlock Metal W Weatherproofing Underlayment -- i Limits of Use y Installation Instructions ( Approved for use in HVHZ:Yes i FL9777 R7 II OCRI4002.4B FBC 2014 Evaluation Rppor� I Approved for use outside HVHZ: No j W theLock Metal HVHZ-final odf ! Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R7 AF OCR 1.4002�4B FBC 2014 Evaluation Report Weatherlock Metal HVHZ- final.pdf Created by Independent Third Party: Yes 9777.5 Weatherlock Specialty Tile'&Metal Weatherproofing Undertayment Limits of Use '°Installation Instructions Approved for use in HVHZ:No ; FL9777 R7 H OCR1400 4A FBC" 2014 .velttaSla!I_i,?e1 L4 Approved for use outside HVHZ:Yes i WeathgrlClrk Non-HVHZ- final,atif Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-105 Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCRlAQQ2.4A FBG 2014 Evaluation Rel>prt Weatherlock Non-HVHZ final.pdf Created by Independent Third Party: Yes Cil Coolant 11 :: 1940 North Monroe Street Tallahassee FL 37399 Phnne:$50-487-182 The State of Florida is an AAJEE0 employer,Copyright 2007.2813 State of Florida. ::Privacy,Statement::Accessibility Statement::Refund Statement _ - Certificate of Authorization No. 29824 43 17520 Edinburgh Drive 40's}s " R E Tampa, FL 33647 TECHNICAL SERVICES, LLC (813}480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 5T"EDITION(2014) . Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19, 2016 1 Owens Coming Parkway Toledo,OH 43657 (800)438-7465 www.oweqscorniqg.com Manufacturing Location: Brentwood,NH Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5, 1507.4.5.2, 1507.5.3, 1507.5.3.2, 1507.7.3, 1507.7.3.2 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-042-02-01 REV2 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI-093-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST6049) OCF-237-02-01 UL 1897 2004 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST6049) OCF-252-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) OCF-272-02-01 TAS 103 1995 PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock®G WeatherLock®G is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate rooting as prescribed in the FBG. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock®Mat Weatherl-ockCR} Mat is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002AA FL9777-R7 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. � r OVEM3CORNING ROOFING AND ASPHALT LLC CREEKvveamvn'nuk0Self-Sealing Ice&Water Barriers TECHNICAL SERVICES. LLC gVeathmrLouWDyNet*i VVaa|hed'ockO&4ata| is an ASTM D 1970 self-adhesive undedoymont constructed from SBS modified asphalt with a fiberglass mat reinforcement and plastic film oodaoa. The product iosupplied in2.0sq.rolls with nominal dimensions of3-Mx5O.7'M. YVaatherLocN0 Metal is panni\<eU to be used with mechanically tysvannd asphalt ohingims, metal roof panels or shingles, wood shakes orshingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck oho|| be limited to a maximum 80 days. VVeatherLouh@ VVeathod'ock@) 8peoiaky Tile & Meta) is an ASTM D 1970 self-adhesive undndoymnn\ Specialty Tile&0}e*m| constructed from SBS modified asphalt and surfaced with a non-woven polyester hsbhu. The product iosupplied in2.14sq.rolls with nominal dimensions of3'ftx71.3'ft. WeatherLockO Specialty Tile&Metal Is permitted to be used with mechanically fastened asphalt hing|oo` o{uy or concrete U(e, metal roof panels or yhing!os, wood shakes or nhing|eo, and slate roofing as prescribed in the F8C. YVaaVhedLmnk0Specialty Tile & Metal ispermitted tobaused with adhered clay or concretetile roofing in either '~ 2-Component Foam Roof Tile Adhesive AH-160 (3yN Company) or TILE BOND'~ Roof Tile Adhesive(Tho Dow Chemical Company). Exposure on the roof deck shall be limited hnamaximum 0Odays. The maximum roof slope aba|| be 6:12 when used with day or ounmeUo tile installations without battens. Tile ohmU be stored on battens for roof slopes greater than 6:12. Tiles shall not bestacked greater 10tiles per stack. ' PRODUCT APPLICATION Min, Roof Slope: 2:12orinaccordance inwith FBC Application* Deck substrates shall be clean, dry' and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application, Prior to beginning k/sta&adbn, the undnoaymont shall be unrolled and allowed torelax for aminimum of3'5minutes. The undeMaymontnhaU be installed with the m|eooe backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel bthe eave. starting otthe eave. and with minimum 3" side }mpm and minimum 6^ end laps staggered 64t. from preceding course. End laps for VVeotherLook(R)Specialty Tile &K4eto|aheU be primed with ASTN1 D 41 primer orsealed with asphalt roof cement aminimum nf34inches across the width ufthe lap, It is permissible to nail the undndoyment 18-inches on'oonharax needed (nails nko8 be installed perpendicular to deck with the nail heads flush to the bop surface of the undadeyment). VVeathorLook@ Specialty Tile & Metal ahu|| be back nailed when installed onroof slopes gvaaiorthan 3:12. For valley appUcadons, the m\{ shall be applied centered along the valley prior to installing the undedaymenta\the eaxe. Foroevn pmhedion, the undadsyment should extend tuapoint 24-inohouinside the exterior wall. The undedayment shall beinstalled over metal drip edge atthnd under the drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install the underlayment under the drip edge in accordance Section 1507.2.9.3. Min.Application 4O"F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. OCR14002.4A pL9777n7 Page 2v/4 OWENS CORNING ROOFING AND ASPHALT LLC CREEKWeatherLockO Self-Sealing Ice&Water Barriers TECHNICAL SERVICES. LLC FIND RESISTANCE _ ,_ The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlavment System No.1 Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied underlayment shalt be rolled with a minimum 751b steel roller immediately following application. Maximum Design -105 psf Pressure: GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the-FBC requirements. 6) All'side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. OCR14002AA FL9777-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. OWENS CORNING ROOFING AND ASPHALT LLC CREEK WeatherLock@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICES., LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 5h Edition(2014)as evidenced in.the referenced documents submitted by the named manufacturer. R 2016.04.19 E N 'X No 74021 15:51 :11 -04'00' STATE OF Zachary R. Priest, P.E. 0 R Florida Registration No.74021 % Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE GREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing, products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002AA FL9777-R7 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation.report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein.