FL# FL2569-1110 Q ,
Application Type Revision
Code Version 2014 ` p
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400 Ext 3327
memath ieu@sap rema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memath ieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
j(cote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer,or Architect Name who developed Robert J. M. Hieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/1G/2017
Validated By John W. Kriezevich,PE
�A Validation Checklist- Hardcopy Received
Certificate of Independence EL 2569 R10 COI 2015 01 C0I Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6163 2000
ASTM D6164 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
TAS 110 2000
http_//www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQWtDgsKQFEnc1:B 10... 8/19/2015
rlonda Building Code Online Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/29/2015
Date Validated 07/02/2015
Date Pending FBC Approval 07/09/2015
Date Approved 08/18/2015
Summa of Products
FL# Model, Number or Description
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R10 II 2015 06 J. L ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes RSO.pdf
impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE-59166
Design Pressure: +N/A/-90 Created by Independent Third Party:Yes
Other: 1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use.2.)The design pressure FL2569 R10 AE 2015 06 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569
noted herein pertains to underlayment R10.pdf
systems used beneath adhesive-set tile Created by Independent Third Party:Yes
systems. Refer to ER Section S.6.4 for
details.
iea�k Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Ccovrfaht 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However entail addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,FS.,please click here.
Product Approval Accepts:
http://www.floridabuiIdin-.org/nr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 10... 8/19/2015
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
ERD 353 CHRISTIAN STREET,UNIT#13
IF OXFORD, CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Soprema,Inc. Evaluation Report S18010.06.09-118
1640 rue Haggerty FL2569-R10
Drummondville, Quebec J2C 5138 Date of Issuance:06/15/2009
Canada Revision 8:06/29/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
���\�1tic t+�ferer.,rf�
Robert J.M. Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen,
'rr,So:"••�•"'9�•� P.E.on 06/29/2015.This does not serve asanelectronically signed
Florida Registration No.59166,Florida DCAANE1983 : �rO�al�i• document.Signed,sealed hardcopies have been transmitted to the
� Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
t 1 IINN I ` t ERLs+r
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following
sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D5163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 2000
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entilnt Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Physical Properties/Accelerated Weathering SOPC SC9520.14 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering,non-woven polyester fabric surfaced,SBS modified bitumen roof underlayment.
4.2 Lastobond Shield is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available
in two widths;36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch.
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.7 Lastobond 195 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R8
Certificate ofAuthorization#9503 FL2569-R10
Revision 8:06/29/2015
Page 2 of 6
N -1 'ERD
4.8 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.9 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, 565 modified bitumen roof
underlayment.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width.
4.12 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified
bitumen roof underlayment,with a 36-inch sheet width.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 44-inch sheet width.
4.14 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment.
4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1E ROOF-COVER OPTIONS-
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate
Shingles Shingles
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastobond/Lastobond 195_ Yes No No No Yes Yes
t
on C, f RESISTQLBT236�,
- 1 - ave al ey P,ro.eet /i•� Yes No No No Yes Yes
EIESIT ST r(3T2A.
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1
Yes Yes
Unilay(e) Yes Batten Only See 5.5.1 No No No
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion/ long term aging data from an
accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond—Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-118
Certificate of Authorization 49503 FL2569-R10
Revision 8:06/29/2015
Page 3 of 6
I RNM4 .ERD
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-S
applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow'Pine; ASTM'D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector,
RESISTO LB1244 or Lastobond Smooth Seal HT applied to^
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
> Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
> While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with
Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
> Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S or Colphene FR GR applied to:
➢ DensDeck DuraGuard;DensDeck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Layer:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S or
Colphene FR GR applied to:
> ASTM D226,Type I or 11 felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems,base layer shall be attached in accordance with
FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R8
Certificate of Authorization 119503 FL2569-R10
Revision 8:06/29/2015
Page 4 of 6
| \����
�4���� K Y /��^u�
'
5.6.4.3 Maximum Dean Pressure -60.0 psf.
Deck Min.19/3l-inchplywood tomeet project requirements tusatisfaction uyAHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attach ed with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three,equally spaced rows in the
center of the sheet.
Undedaymem: Cn|phene;RGR,self-adhered
5.64.4 Maximum Design Pressure=-90.0 p
Deck: Min.l9/3Z-inchplywood tomeet project requirements tosatisfaction ofAH1
Under>ayment: Unilay(e)mechanically attached with Soprafix Polymer Batten Bar(PBB)or Soprafix Metal Batten
Bar (xx88) with Soprema #15'EL fasteners spaced 6-inch oz. within the 5-inch wide' self-
adhering side laps. End laps are 6-inch vide and sealed using either heat-welding nr hot-air
welding techniques.
57 Exposure Limitations:
5.7.1 Lastobond Shield, iamobnnd Pro HT'N, RES|5T0 SA SMOOTH PLY 40, iagobond, La$ohond 195'Lagmboud Eco'
Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left
exposed for longer than 3O'daysafter installation.
5.7.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation.
5.7.3 Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-days after installation.
6' ImsrxLunIom:
6.1 Sopnema Roof Undedaymemsshall be installed in accordance with Somema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
5.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly toremove
any dust and debris prior to application,and prime the substrate with Elastocol Stick or Elastocol 600c(if applicable).
Lastobond TU HT, Lastobond Shield, Lastobond Pro ��O �� gmoOmp� w\
6.3
Lastobond Shield HT,
Lastobond Pro HT-S,Lastobond,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LIB1236,Grip-
6.3.1 Shall beinstalled mcompliance with the requirements for ASTM "^,'" ".."e..",".=..`". ."^~~^^.~.~ ^~~' for the
type nfprepared roof covering tnbeinstalled.
6.3.2 Non-Tiie Applications:
While nhndng is optional,Sopnema recommends priming with Bastoco|Stick or Basu,cn\600c ifthe final roof cover
|snot slated for installation within I4hours.
Apply sheet parallel tothe roof edge. Roll out approximately Iuftofmembrane and peel back the first 3 ftofrelease
film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place tnachieve abond.
Horizontal seams should he minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using
either heat-welding urhot air welding techniques.
When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet
atlz'inchnz.
For Valleys and Ridges: cut under|oyment into 4 t 6foot lengths. Peel the release paper and center sheet over
valley or ridge.Drape and press sheet into place,working from the center of the valley or ridge in each direction. For
valleys,apply the sheet starting atthe lowest point and work upward.
sa.s :
Reference is made to FR6A/TK| April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above asaguideline.
For Co|phene FR GR in foam-on tile applications, reference is made to 3erdnn 5.6.4 herein for wind resistance
limitations.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Exterior Research and Design,I.I.C. Evaluation Report s18mzouso*mo
rosem�
a"�aa�wn"momm��uana
Revision u-os/xy/zo1s
Page smo
� E���
T��
In�K y Y! ^��
6.4 UnNay(e):
§A.1 Non-Tile Applications or Nail-On,Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if applicable).
Apply sheet pan^Ud to the roof edge and,starting at the eawe with the selvedge-edge ups|ope,mechanically attach
the 5-inch wide selvedge-edge tnthe wood deck with nails and tin cops or round cap-nails spaced 36-inch o.c Apply
the second course /n a water-shedding manner with self-adhering side-laps. Vigorous hand o, motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below, All over-
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
xer-gmnu|eend'|apsshaUbeseuledusin8eitherheat+we|diuQorhntairwa|dingtechniques.
Tile (if applicable) shall be loaded and staged in a manner that prevents tile slippage and/or damage tothe
under\ayment.
6.4.2 Foam-On Tile Applications:
Reference ismade tnFR3AfTR April 2D12(O4- 2)|ngaUabonxoanualwndTmbie1henein.
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attach
the 5-inch wide selvedge-edge tothe wood deckSnpraUx Polymer Batten Bar (PBB) o,Soprafix Metal Batten Bar
(k48B)with Soprema#15'ELfasteners spaced O-indho.c. Apply the second course inawater-shedding manner with
self-adhering side-laps, Vigorous hand ormotorized roller pressure is applied tnthe self-adhering laps toensure e
watertight application.
Vertical seams should be6-incheoand staggered not less than 2-ft from vertical seams inthe course below. All over-
granule end-lapssheUbexea}edusinueitherheat^we|dingorhotairwe/dingtechniqucs.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation ufthis product.
Q. MxmuewCrummG PLANTS:
Contact the manufacturer orthe named QAentity for information onplants covered under Rule 6IG2V-3 QA requirements.
9. QUALITY ASSURANCE Emnn/:
UL,LLC—QUA96Z5;(31U578-34O6;k.chnncoKnr@ux.uiconn
-END oFEVALUATION REPORT'
'
Exterior Research and Design,LLc Evaluation Report s1ou1auau9-nn
Certificate of Authorization#9503 n2569-RlO
Revision u-os/o9/2oas
Page svxa
VIULILltt DLtIH.tIEtl- t—oae 1.t2 nne Page 1 o 2
r
6CIS Home Log In User Registraticr: He,Topics Submit Surcharge Stars&Facts Publications FBC Staff BCIS Site Map Links Search
i7
_USI !e
i Approval
} (.al a {Q�EGi (`- -',FUSER:PublicU ser
Product Approval J!IEnu>product cr Apnlice tion Sear�h>Aonlication List>Application Detail
Fr __ •- .1
FL= Fuas74-R1fl
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Arrhivpri
Product Manutacturer Ovvens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
gi,eg.keelet,@otvenscorning.com
Authorized Signature Greg Keeler
greg.keeler@orvenscorninq.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Caning PKVdY
Toledo, OH 43659
(419)376-8360
mel.sa n cra n t@o vre ns cg m ig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or-a Licensed
Florida Professional Enaineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Plame who developed Robert J.H.Plieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08,20/2017
Validated By )ohn W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674_RIO._COI_,20 5_0-1-COI_Hieminen._pdE
Referenced Standard and Year(of Standard) Standard Year
ASTH D3161 2009
ASTM D3462 2009
ASTH D715S 2008
Equivalence of Product Standards
Certified By
Sections from the Code
i1tcU:JJ�vwty.11oriciabuiidin,.ol;�/pr/pr app citl-aspx?�aar�Im=NvGEA%<'QQNNlDgtBNbEY5-\iio2--. 9/15/2015
1-11JILUM6 %_VUU U11111le Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 04/22/2015
Date Validated 04/23/2015
Date Pending FBC Approval 04/2512015
Date Approved 06/23/2015
Summary of Products
FL# Model,Number or Name Description
10674.1 0%,vens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:Na FL1o674 R10 II 2015 04 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R10p f
Impact Resistant:N/A Verified By: Robert 3.M. Nleminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other:Refer to ER,Section S. Evaluation Reports
FL10G74 R10 AE 2015 04 FINAL ER OC ASPHALT
SHINGLES_A�10674-Rlo.p&
Created by Independent Third Party:Yes
&acct Next:;
Contact U :*.1940 North Monroe Street.Tallahassee FL 32399 Phone:850-497-1824
The State or Florida is an AA/EEO employer,Cogyright 2007-2013 State of Florida-::Privacy Statemen ::Accessibility Statement::Refund statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts.
El
http://www.floFidabuildincy.orc,/ r/pr app iii
dtl.aspx?para ==wGEN,XQwtDqtBNbEY5V%2... 9/15/2015
P
' EXTERIOR RESEARCH{&DESIGN,LLC.
Certificate of Authorization#9503
353CHRISTIAN STREET, UN[T#13
U ~��� 'k�����
� �� U 8 !u~���� OXFORD, CT 06478
PHONE:(Z03)ZG2-9245
FAX:(7O3)Z62-9243
EVALUATION REPORT
Owens Corning Evaluation Report 03794O'82,12-RS
One Owens Corning Parkway FL10674-Rl8
Toledo,OH43GS8 Date mfIssuance:82106/2Q12
Revision 5: O4/22/2O15
Scopu
This Evaluation Report is issued under Rule 62G20'3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building[ode, Residential Volume. The products described
herein have been evaluated for compliance with the 5'h Edition(2014)Florida Building Code sections noted herein.
Dcscmpnow: Owens Corning Asphalt Roof Shingles
Lxasums; Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report isvalid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance ofthis
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the _
referenced Quality Assurance documentation changes. Trinity IERDrequires acomplete review nfthis Evaluation Report
relative toupdated Code requirements with each Code Cycle.
AovsnTocxncmc The Evaluation Report number preceded by the words "Trinity(ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
|mxpscnom: Upon request a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists ofpages 1through G.
Prepared by:
m°u�/°v"`�,"p~"�v°=""m^*" �x�" m"°m�
RmbertJ'KD.Niemmyneu,P'E """�" "~" =
P.E.""moz�u�mu��"�""°"=""electr"*=lly signed
Florida Registration No.59ua6,Florida ocxAvuo98o ` ` ''"`` document.Signed,sealed^"rd=,ies have been transmitted mthe
Product Approval Administrator and mthe named client
CERTIFICATION cpINDEPENDENCE:
1. Trinity|EnD doe, not have nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products itevaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have,nor will acquire,a financial interest in any other entity involved in the approval processof the
product.
5. This i,abuilding code evaluation. Neither Trinityl ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
8 � �|����
��»�
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
5u6-Category: Asphalt Shingle,
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance
with the following sections of the Florida Building Code and Florida Building [ode, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of
Use set forth herein.
2' 5rAmoxnos'
Section Property Standard Year
1507.Z5,R905.2.4 Physical Properties ASTM D3462 zooy
1507.2.7.1,R905-2.6.1 Wind Resistance ASTM D3161 zoos
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 aoom
3' Rcrcnemcss:
aEn� Examination Reference Date
uLLLC(csnyaua) Physicals mWind Resistance File x24oa'Vol.u 02/15/2007
uLLLC(csnesza) Physicals mWind Resistance 20120516-112453 05/16/2012
uLLLC(Tsreszu) Physical Properties 06cx20263 04/18/2006
UL L»c(rSTsozo) Wind Resistance zzcxa*nou ou/n*zuzz
UL Luc(rsTyoao) Physicals mWind Resistance 4786093137 02m1/2014
uLLLC(cST9azu) Wind Resistance 4786126532 02/10/2014
uLLLC(Tsn9o2u) Physical Properties Classification letter 02/13/2014
w/ami-oaue(csxzsyz) puc*vxzCompliance v^,m,uwoA, Various
UL LLC (ouAyozs) Quality Control Service Confirmation,xm5a exp.08/20/2017
4' PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic*and Supreme'are fiberglass reinforced,3-tabasphalt roof shingles.
4.1.2 Berkshire'are fiberglass reinforced,4-tabasphalt roof shingles.
4.1.3 Devonshire'are fiberglass reinforced,5-tabasphalt roof shingles.
4.1.4 Duration', rruDef|nition~ Duration', Duration' Premium Cool, TmoeMnibon° oumtion^ oesiQmc, Color Collection,
T,uDeMnition~Oakridge~'Oakridge'and VVpatberGuard~HPare fiberglass reinfo�ed.laminated aspha�mofshingles,
4.2 Berkshire' Hip & Ridge �hing/es, High Ridge, Hip & Ridge with Sealant, Vveather3ua,d~ HP Hip & Ridge Shingles,
PmEdgeHip Q Ridge Shingles and oucaffidge� Hip & Ridge5hing/es are fiberglass reinforced, hip and ridge asphalt
roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. L/xx/nn/omS:
5.1 This i, a building code evaluation. Neither Thody|Eno nor Robert wleminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, /s/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report isnot for use inthe HVHZ.
5.3 Fire Classification is not part of this Evaluation Report, refer to current Approved Roofing Materials Directory for fire
ratings ufthis product.
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with p8[Tab|es 1507.2.7.1 and R905.2.6.1 to
ASTM o3I61,Class rand/or ASTM o7158'Class H'indicating the shingles are acceptable for vs in all wind zones up to
yZm^=zSVmph(V,*=z94mph). Refer toSection 6 for installation requirements tomeet this wind rating.
5.4.3 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables
15o7.uIzand V9O5.z.6.ltoASTM o31s1,Class F, indicating the shingles are acceptable for usinall wind zones upto
V,m=z5Omph(V.1,=z94mph). Refer tnSection Gfor installation requirements tomeet this wind rating.
smerimResearch and Design,LLC. Evaluation Report os7y4o.0zz2-ns
Certificate afx"m"uzauonmuao ru10674-nIo
Revision s'm/u42nzs
Page 2ma
_
�
���
0 K�I� �NK U `^�'«��
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet urless. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific uzeach shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and
pJ�cRule OI620'a.
6. \mSTnLunnom'
6.1 Onderloymemz
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 01G2O-3,per F8CSections 15U7.Z.3,15O7.2/4nrR9U5.l.].
s'z Asphalt Shingles:
6.2.1 Installation ofasphalt shingles shall comply with the manufacturer's current published instructions, using minimum
four(4)nails per shingle|naccordance with F8CSections 1SO72orn9OS.2,with the following exceptions:
> Berkshire'shingles require minimum five(s)nails per shingle.
> Vveathepsua,d,HPshingles require minimum six(6}nails per shingle.
> ncxonsh\re'shingles require minimum six<6>nails per shingle.
)�- Starter Strip Plus requires minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or
n905.2.5- Staples are not permitted.
62.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fasten/ng are required.
Contact the shingle manufacturer for details.
5.2.5 Minimum Nailing—[|assicw&Gupreme:
N Normal Mansard or Area para Mormal Mansard or Area para
Wind Areas High Wind desvonas y Wind Areas High Wind dusvones y
Area porn vientos normajes Areas vientos fuerres Area para vientas normales Areas Vientos fuertas
W'Exposure 5 518'Exposure
6.2.6 Minimum Nailing—BerksbireO'
a��m ���o�����
ex�no,ne�aoh�dneuun LLC. ..
� azou��nzn
o�����m����
Revision s.nw2a/2uzs
Page ama
T
IN �( 'ERD
6.2.7 Minimum Nailing—DevonshireT":
Nails
L
Nails Ten 1"Spots of Asphalt Roof Cement
6.2.8 Minimum Nailing—DurationO,TruDefinition®Duration, DurationO Premium Cool&TruDefinition'Duration'Designer
Color Collection:
4 Nail Pattern6 Nail
Esquerna do 4 claws Pattern Y1.110 alutotrl_
Esquema
Sur eNait"bsterving area rAcith
Areideclawssurellaip do 6 clavos ;gj;shjnz care C!
o =3 t;3ao V!3 rzlo
MJ
T—IS1010
Aro da T.
dw-5
,jW!2Z1
G..
5a,"Expasure S' poure
5 i Pping.de exposicidn Nail, —T Ex
cla Vo.,; 5`4pmlg.de EXPOS16611 55'V Expmre Nail, Expo-Sure
P,:pdg.de upoiki6i? rMm 5$6 pul1g.de exiwsickir.
6.2.9 Minimum Nailing—TruDefinftion*Oakridgea',Oakfidge":
4 Nail Pattern 6 Nail Pattern
Esquerna carr 4 clavos Esquema con 6 clavos
7r
12
5518"Expoure —Xr—
Nails 5 519"Exposure Nail.,
&P osidda de 5 5618 P u1g. C13YOS Expx)sld6n d&6 9/spula. 55,''8"Exposure Clam, 5 518,,Exposure
Eyp c Ktc!6 t?do'VS p afg. Exposic.`6n da 9 518pufg.
6.2.10 Minimum Nailing—WeatherGuard"HP:
Ingle Slift wilew
4
Fw*KwThMU2hHdlLkw
an 12*Vag Sh f4be"M
..--a
Exterior Research and Design,LLC Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 FL10674-RI0
Revision 5:04/22/2015
Page 4 of 6
�
��������"
6.3 Hip&Ridge Shingles:
6.3.1 Installation ofBerkshire' Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,Vxoat e,Guard' HP Hip and
Ridge Shingles and pooEdgeHip&Ridge Shingles shall comply with the manufacturer's current published instructions,
using four(4)nails per shingle. Installation of DuraRidge�Hip&Ridge Shingles shall comply with the manufacturer's
current published instructions,using two(z)nails per shingle. Refer u/Owens Corning published information nnwind
resistance and installation limitations,including the use of hand-sealing for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or
n905'Z.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire'Hip&Ridge and High Ridge:
xeds
"'K top L.Wnalj
me
6.34 Minimum Nailing—Hip&Ridge with Sealant:
rrirn Shingle Nails)
and Discard
EX ce_ss -14 el
Fastening Vj�,
12
6.3.5 Minimum Nailing—VVeotherGuardOHPHip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A Top Wzw
Nails
Exterior Research and Design,uc Evaluation Report 037940.02'12-R5
Certificate afx"m"rizommm95m Fo0674-nso
Revision s.o9/2z/zass
Page sofs
` T INI D
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevai9ing Standartl
Wind Direction Fastening
Sealant Strip ., Pattern
6°Exposure
d
Sealant
Fasten Th" 7.t=„ 6"Exposure
Cover Exposed
\\ Fasteners with
Roof Cement
6.3.7 Minimum Nailing—DuraRidgeT"Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
pni-ailing gird r)irc.:dcn Top Vie-
r Diroaion donAronco duwnc Vua en plan
DirociondQI-4ntapro&rair,=4 at t' Vimsupartc'r IT—>
--'-
tlai ° Owns Corn_iruj Summ�it•_-
u,
_-�
lav f-1 2—Ny
CI,rEos'=� a
�q 4
y�'..3IIt Ula
a5L3 I
��ass•�E��i ,� Iia
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;I:aren.buchmann@ui.com
END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
Certificate pf Authorization#9503 FL10674-R10
Revision 5:04/22/2015
Page 6 of 6