Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVALS
MEW t lfrofessional .-o uiation 13CIS Home Lag In I User Registration ' Hat Toptcs Submit Surcharge Stats & Facts Publications I FBC Staff i BCSS Site Map I Links Search Oria Product Approval USER: Public User Prcci—t Approval Menu > Product or Application Search a Apphcatwn Lsl > Application Detail FL # FL10674-1112 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel . sa ncra nt@owensco rnig. corn Roofing Asphalt Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert ].M. Nieminen PE -59166 UL LLC 08/20/2017 John W. Knezevich, PE r' Validation Checklist - Hardcopy Received FL10674 R12 COI 2D16 01 COI Nieminen.oddf Referenced Standard and Year (of Standard) Standard ASTM D3161 ASTM D3462 ASTM D7158 Equivalence of Product Standards Certified By Sections from the Code Year 2009 2009 2008 Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 Summary of Products FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R12 iI 2016 04 FINAL _ER OC ASPHALT SHINGLES FL10674-_Ri2.adf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified 6y: Robert]. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section S. Evaluation Reports FI -10674 R12 AE 2016 04 -FINAL ER OC ASPHALT SINGLES FL1Q674-R12.pdf Created by Independent Third Party: Yes Sade Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 3Z399 Phone: 850-487-1824 The State of Florida 15 an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: A5ccessibility Statement :: Refund Statement Under Ftorida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. most provide the Department with an email address if they have one, The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S„ please click here . Product Approval Acemapts: F_ dam!:: 0 Credit Card Safe <, ks` TRINITY ERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization 1!9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 037940.02.12-R7 FL10674-R12 Date of Issuance: 02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: +��545.+ttrrrA,ri et The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M. Nieminen, P.E. vi ].L� c4y. I.E. on 04/18/2016. This does not serve as an electronically signed i, W U •,t Florida Registration No. 59166, Florida DCA ANE1983 :'"""' document. signed, sealed hardcopies bay been transmitted � the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityjERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.F. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity jERD nor Robert Nieminen, F.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY . ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7159 2008 R. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties OGCA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Qua Iity Control Service Confirmation, R2453 Exp. 08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic' and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles. 4.1.2 Berkshire' are fiberglass reinforced, 4 -tab asphalt roof shingles, 4.1.3 Devonshire'" are fiberglass reinforced, 5 -tab asphalt roof shingles. 4.1.4 Duration', TruDefinition® Duration', Duration' Premium Cool, TruDefinition' Duration' Designer Color Collection, TruDefinition®Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgel Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Rall are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization #9503 I L10674-1112 Revision 7: 04/18/2016 Page 2 of 8 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Va,d = 150 mph (V„ It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vaad = 150 mph (Vr,it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61020-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or 8905.2, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle. ➢ Devonshire'' shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus; Felt undedayment Deck r. Sel£-adhered Weatheri.osk' `{� undetlsyanent Urip Drip edge edge Nails located 2"--3" from eave Install first W -sealing adhesive Starter Stn positioned along eave shingle v,Rth 6" removed Starter Strip shingle overhangs eaves and rakes lr -1i" Exterior Research and Design, LLC. Certificate of Autharization #9503 ralr underfaymerat Dedr SdFedhxed WeatherLocttt unrbdwpmant Q ip edge " Nai1r loutvd T-3- from care iMail first Stnssrsay wu S4lrsas*ngkvg eae WO 6- MW= pasrrior#d ilRnQ COYC Starter Strip Piva werhwVs ww a and rake. VC -314" Evaluation Report 037940.02.3.2-R7 F1.10674-1112 Revision 7: 04/18/2416 Page 3 of 8 6.2.6 Minimum Nailing— Classic" & Supreme: Normal Mansard or Area para Wind Ames High Wind desvanas y Area para vienres normales Areas vientoe fuerte+ 2. 1. 71' 11' i S"Exposwre 6xposiel6n 6.2.7 Minimum Nailing--BerkshireO: Standard Fastening Pattern TRINITY ERa Normal Mansard or Arse para Wind Areas High Wind daatrwrres y Area para viantos norrnalee Areas vh nros fuerres 72 1 5 518` Exposure Enposicidn Sealant strip La tira de mflador e +----. 1- e 0-0-0 8 112' 8'2° 8 4" 8 1J2" 6 -Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 Certificate ojAuthorlration #9503 FL10674-11 2 Revision 7:04/18/2016 Page 4 of $ 6.2.8 Minimum Nailing— Devonshire'": �YI 8" Gma --- 5-5l8" exposure Sealant location Exposid6n de 5 -518 puig UbW6n del seb or Standard 6 -Nail Fastening Pattern TRINITY' ERD Nails Ten t" Spots of Asphalt Roof Cement Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, Tru Definition Duration, Duration Premium Cool & Tru Definition Duration Designer Color Collection: 4 -Nail Fastening Pattern StaaNanA fxunirrp arae rvidtlr NMI, TW -1 1^ 12' s-1re^ sare- Standard Fastening Pattern 6 -Hail Fastening Pattern l— Su NWl®rasHRinga .dth j f Nail, 7YW^..al 1 12 f jj( jj 1r 1 W -e F1 F� R a.1re^ tea'. 6 -Dail Fastening Pattern Fastening for Slopes Greater Than 21:12 3.—N—.W—mr."�„ean. krh W7f, Typical s' 12' —, +!r 1. SOW asn^ Pow 1' Spats of AlphO Rooang Ce t Mansard or Steep Slope Fastening Pattern Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7 Certificate of Authorizotion #9503 FL10674-1112 Revision 7: 04/18/2016 Page 5 of 8 62.1. Minimum Nailing — Tru Definition' Oakridge®, Oakridge®: 4 Nail Pattern EsguAmo con 4 cfavos 1' 1 rr WT Exposure Naas 5 519" Exposure Expasleicn de 55/SPulg. Clavas Exposiriaa de � 5/Sp+d�t Standard Fastening Pattern i TRINITY ERD 9 Nail Pattern Esquema con S davos 1' T I 5518" Expvsue� 5518" Exposure L padd6n de 55/8 palg. Espasieba de !i 5/8 pag. 6 -Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 sur.r��v rs:te� maE wiaa+ Rei Nt" ays• ss�s _ 0 sour 1^ spm. & Aaphln Rooting C--1 Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard' HP: FF �� �7 � 1/l�s iUei�ral Exterior Research and Design, LLC, Evaluation Report 037940.02.12-R7 Certihcare ofAurhorization #9503 FL10674-R12 Revision 7: 04/18/2016 Page 6 of 8 .' TRINITY ERQ 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of QuraRidge' Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge: Fig. 4 4 F— PmvaWnpWtd D1red4Dn %� A 4 A I I q I I I I I e" )I EZNLl�esufe Fig. 2 Top%hew Side View Nall Nall Tn"Minaled Z.. C were moi. I i 8" i .I �I �E I u� I 6 I 6.3.4 Minimum Nailing — WeatherGuard" HP Hip and Ridge: Exterior Research and Design, U.C. Certificate of Authorization #9503 Fig. C Hip & Ridge Shingle Fastening ToPVlew t.Nl6s Hells r' S' ECP©gNw 73" I Evaluation Report 037940.02.12-127 FE10674-1112 Revision 7.04/18/2016 Page 7 of 8 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip Av--� 6' Ecposure Fasten Th' Cave"rymaad Fasteners with Roof Cement TRINITY ERD Standard r-- .-3t•.-.-- —. Fastening Pattern l— tx• relent B' Erpas In. 1 q I• f2' ` 6.3.6 Minimum Nailing — DuraRidgel Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. lap Vow ww an p4m �-s;^ Vitra yynerwr I�.. GxNj Surd4ar s � I I I� db $ �E tY" I 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named Q4 entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE IENTITY: UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037440.02.12-R7 Certificate of Authorization #9503 F1.10674-1112 Revision 7: 04/18/2016 Page 8 of 8