HomeMy WebLinkAboutProduct Approval (2) .OO E
THROUGH FRAME
FR ,.IDSC;3
INSTALLATION
_............_....._...___.__.._._._......_._._..__ _....___.. _ _....._.._............
o / l z i
Q AX ,112,MIN 114'MAX
' SWM
SP
A b•fit. scet SPACE EMBEDMENT SHIM SPACE
'19.b•O C.MAX. 'MIA
1 ® TIMJJAMBQ a
i. MIN.DISTANCE 2
.. FROM EDGE:314' .rte
All
4.7—
bow 995
7rsmnowsss �
V5 RITE
--ROM EOSE 3 4• 2 �•oo :
GLA ZING.OETAIl. - - �a-o -- N---------- I
- -
--- WOOD FRAME SECTION(TYP) 1
VERTICAL SECTION
tI
FRAME IAM6 5ECTION.(TYP)__
1 I HORIZONTAL SECTION r
1 - mm WM(710.828•MM)
l TYPICAL ELEVATION WITH FASTENER SPACING Q I
i
TWO,THREE AND FOUR PANEL ! ❑ knu svnre j
i CONFIGURATIONS APPROVED I i
1112,MM a :
' b SLIDING PATIO DOOR
3
•'MW nzsTnxcE• -
Max Frame DP RATING IMPACT I
FRgMEaGi:3.' 1190 5/8" x 951/2"1 +/-50 1 YES s
�i..._...__..._._._....__ ._.........._......__._....._._...__.__..............._._.._............_......-................._.._Large and.Small Missile Itnpact_....._._.____f
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of
2, Use(2)-910 PH or greater fastener through the frame per location with sufficient length to penetrate a the adopted International Building Code(IBC);the Intemational Residential Code(IRC),the Florida
minimum of 11/2"into the wood framing. For 2x wood frame substrate(min.S.G.=0.42). Building Codes(FBC)including HVHZ and the industry requirements for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility.of the architect or engineer of record for the 3. At minimum,glazing is 3/16"tempered-airspace-3116"annealed-0.09"SGP Intedayer by DuPont-
project of installation. 3116"annealed.
4. Use structural or composite shims where required.
5. Installation methods can be interchanged within the same opening.
6. An impact protective system is not required where wind bome debris protection is mandated by local
This schedule
ired
anchor the %%ttil
windowo achieve rtheeatedly the design asteners pressure uputo theosize limitations ��0 1 ES.1F.fill/4,Obuilding"" 7. Mamm sizes are buck sizes and do not include fin or flange.
noted. It is not intended as a guide to the installation process and does �� •• . �� PROJECT ENGINEER: DATE
,. 3737 Lakeport Blvd.
not address he sealing consideration that may arise in different wall � '� !, -- 02/25J13
*� ;• Q � ,[�r .■�N Klamath Falls,OR.97601
•� DRAWN BY: SCALE:
conditions. Far the complete installation procedure,see the instructions .. ,• 1
packaged with the window or go to " y 7 y -• D.Vezo NTS Phone: (800}535 3936
7C . CHECKED 8Y: TITLE:
www.jeld-wen.comiresourceslinstallation• T T J. Kantola
DISCLAIMER: = w APPROVED Premium Atlantic Vinyl Sliding Patio Door OX?CX
'.d� ••;�0 OP' ��.` Through Frame Installation(190 5/8"x 951/2")
This drawingand its contents are confidential and are not to be �� s•2Q'dre P RT
reproduced or copied in whole or in part or used or disclosed to others � , , �b��b 1
except as authorized by JELD-WEN Inc. 308 D O B to 398 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET
tFptq�t>ka NCTL210-3851- -FBC Venice, FL 00 zoFa