HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 2
-
BCIS Home ; Log In i User Registration Hot Topics Submit Surcharge 1 Stats&Facts Publications FBC Staff BCIS Site Map Links Search
F!ord� n
{ .� Product Approval
USER:Public User
Product Approval Menu>Product or Aoolication Search>Aoolication LIS t>Application Detail
ar FL# FL10124-1119
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer GAF
Address/Phone/Emall 1 Campus Drive
Parisppany,NJ 07054
(800)766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
Iindareith@trinityerd.com
Technical Representative Beth McSorley(current)
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 03/03/2018
Validated By John W. Knezevich,PE
0 Validation Checklist-Hardcopy Received
Certificate of Independence FL10124 R19 COI 2016 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Y4.AL
ASTM D1970 2009
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
TAS 107 1995
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdM... 2/8/2017
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 08/26/2016
Date Validated 08/26/2016
Date Pending FBC Approval 08/30/2016
Date Approved 10/13/2016
Summary of Products
FL# Model, Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated,5-tab and hip/ridge
asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10124 R19 II 2016 08 FINAL ER GAF Asphalt
Approved for use outside HVHZ:Yes Shinoles FL10124-R19.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10124 R19 AE 2016 08 FINAL ER GAF Asphalt
Shinoles 1`1_10124-R19.odf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
..........—'---....._.................-_....
Cr6dit Card-
Safe
W=
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDquracBeVCbdM... 2/8/2017
TRINITY I ER®
Certificate of Authorization#9503
January I,20.16
RE: -Certification of Independence,:Florida F.A.C. Rule 61 G20-3
To Whom.It May Concern:
This letter serves to document the following in accordance with Florida.F.A.C. Rule 61 G20-3:
1. Exterior Research&Design, LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or
will it acquire,a financial.interest in any company manufacturing or distributing products it evaluates.
2. Exterior Research,& Design, LLC. d/b/a.Trinity I ERD is:not owned, operated or controlled by any
company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company
manufacturing:or distributing products for which the.evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a.financial interest in any other entity involved
in the approval process of the product.
5. Building Code.Evaluations issued by Trinity.IERD and Robert.Nieminen, P.E.are not,in any way,to be
construed to mean or imply that TrinitylERD or Robert Nieminen, P.E.are the Designer of Record
for any project on:which the.Evaluation:Report is/was used for permitting or design guidance unless
retained specifically for that purpose on a given project.
Please contact our office with any-questions..
Sincerely,
Robert Nieminen, P.E.
Florida Reg.No.59166
Vice President
Email:robertnieminen@triniityerd.com
EXTERIOR RESEARCH &DESIGN,.LLC. d./b/a Trinityi ERD - Certificate of Authorization #9503
MAIN:80 Yesier Way . Suite 200. Seattle, WA 98104 . P: (206) 467-0054 . F: (206) 467-5840
EAST: 353 Christian Street Unit 13.. Oxford., CT 06478 . P::(203) 262-9245 • F: (203) 262-9243
EXTERIOR RESEARCH&DESIGN, I.I.C.
F)o Certificate of Authorization#9503
T��N�TY 353 CHRISTIAN STREET,UNIT
1
ERD OXFORD,CT 06478478
PHONE:(203)262-9245
FAX:(203)262-9243.
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1121,
1 Campus Drive FL10124-1119
Parsippany,NJ 07054 Date of Issuance:01/03/2008.
Revision 21:08/26/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the,State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code: and Florida Building Code; Residential Volume. The
products described herein have been .evaluated for compliance with the 51h Edition ;(2014) Florida Building Code
sections noted:herein.
:DESCRIPTION: GAF Asphalt Roof'Shingles
LABELING: .Labeling shall, be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named. product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that.relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinityl'!ERD requires a complete
review of this Evaluation Report relative to updated Code'requirements with each Code .Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity JERD Evaluated" may be displayed in.
advertising.literature. If any portion of the Evaluation Report is displayed,then it shall be done in its,entirety.
INSPECTION:Upon request,'a:copy of this entire'Evaluation Report shall be provided to the user by the:manufacturer or
its distributors,and shall be available for inspection at the job site at the request of the.Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: +'�J` 3,'•t'%Ii`':'%.��.,
J4-
of
Robert:J.M.Nieminen,P.E. The facsimile seal appearing was authorized by RobertNleminen,
P.E.on 08/26/2016:This does not serve as an electronically signed
..�,✓JUrmrrH
Florida Registration No..59166,Florida DCA ANE1983 document:signed,sealed hardcapies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFicA,noNOF INDEPENDENCE:
1. Trinity I ERD.does not.have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD isnot owned,operated or controlled by any company manufacturing or distributing products it-evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approvalprocess of the
product..
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen; P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SysTErvis'EVALUATION: �PTRINITYJERD
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt'Shingles
Compliance Statement: Asphalt Roof Shingles,as produced by GAF, have demonstrated compliance with the
following sections of the Florida Bu,liding Code and Florida Building.Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
Conditions of'Use set forth.herein.
2. STANDARDS:
Section Property Standard Year
156724,11905-.2.3 Physical Properties ASTM 61970 2009
1507.2,5;8905.2.4 Physical Properties ASTM D3462 2009
15071.7.1,8905.2.6.1 Wind Resistance ASTM D3161
2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM 67158 2608
1507.2.7.1,11905.2.6:1 Wind Resistance TAS 107 1955
3. REFERENCES:
Entity Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant,111 01/13/2012
PRI(TST 5978) Physical Properties GAF-025702-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 69/02/2004
PRI(TST 58'78) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-32402-01 12/61/2011
PRI(TST 5878) Wind Di werr Rain GAF-407-02-01 01j21/2013
UL,(TST,1740) ASTM D3462 93NK6295 11/29/1993
UL.(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94Nk9632 03/29/2000
UL.(TST 1740) ASTM D34.62 01NK06632 02/02/2001
UL.(TST 1740) ASTM D3161,TAS 107 01NK9226 05/Z1/2001
UL(TST1740) ASTM D3161 01NK37122 12/19/2001
UL(TST 1740) ASTM D3462 01NQ7122 12/19/2001
UL(TST 1740) ASTM D3-161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161i TAS 107 02NK30871 09/09/2002
UL(fST 1740) ASTM D3161, 03CAS367 03/11/2003
UL(TST 1740) ASTM 63462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850
06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
.UL(TST1740) ASTM D3161 04NK30546, 03/10/2005
IJL,(TST,1740) ASTM D3462 04NK22009 0.5/06/2005
UL(TST 1740) ASTM 03.161 04N.K220091 05/09/2005
UQTST 1740) ASTM 634:62' OSNK27924 02/16/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST.1740) ASTM D3161;D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST4740) ASTM 173161,.D3462 06CA35251 10/18/2006
-UL.(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM,D3161,D3462 06CA41095, 12/27/2006
ML(TST 1740) ASTM D8161 07NK05228 03113/1007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL,(TST.1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462
07CA131.74.2, 11/08/2007
UL(TST1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2009
UL.(TST 1740) ASTM D3161,D3462 07CA55908; 04/01/2008
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R21
Certiftcate of Authorization#9503 FI.10124-1119
Revision:21:08/26/2016
Page 2 of 6
TRINITY I ERD
Enfint Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST"1740) ASTM D3161;D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM 03161,D7158,D3462 10CA3555'4 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161,07158,D3462 1ONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
.UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408: 12/08/2011
UL(TST'1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST9628) ASTM D3462. 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,.D3462 12CA58151 02/15/2013
UL,LLC:(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161, 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC:.(TST'9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 12/28/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 02/23/2016
UL,LLC..(QUA 9625) Quality Control Inspection.Report,R21,Tuscaloosa,:AL 02/26/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 03/02/2016
UL,LLC.(QUA 9625) Quality Control Inspection.Report,R21,Shafter,CA 02/18/2016
UL,LLC..(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 02/24/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 02/09/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 02/09/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 03/01/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 02/29/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 02/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 02/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 03/03/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax®, Royal Sovereign' and SentinelO are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2Camelot®, Camelot® II, Fortitude'"', Glenwood"; Grand Canyon®,. Grand Sequoia®, .Grand Sequoia® IR,
Grand Sequoia® ArmorShield'"", Monaco®; Sienna®, Timberline® American Harvest®, Timberline®
ArmorShieldTM II,Timberline®'Natural Shadow®,Timberline HD®,Timberline®Cool Series" Timberline Ultra
HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 Slateline®is a.fiberglass reinforced 5-tab asphalt roof shingle:
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles', Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge®
ArmorShield."''Ridge Cap Shingles and TimberteO Premium Ridge.Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
Exterior Research and Design,L.LC. Evaluation Report 01506.01.08-R21
Certificate of Authorizotion.#9503 FL10124-R19
Revision 21:08/26/2016
Page 3 of 6
F)o
TRINIT I ERD
4.3 Accessory Starter Strips:
4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlocker'"'Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3:2' QuickStartO Peel & Stick Starter Roll is a 'is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip;nominal 9-inch x 33 ft roll,for usewith asphalt shingles with exposure of 6-
inch or less.
4.3.3 StarterMatchTm Sharter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatchT"I are installed as the second starter for Grand
Canyon®and Grand Sequoia®series installations.
5. LIMITATIONS:
5.1 This is a building code evaluatioh. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report-is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of-this product.
5.4. Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
11905.2.6.1 to_ASTM D3161,.Class F and/or ASTM D7158; Class'�H, indicating the shingles are acceptable.for
use in all wind zones up to Vasa=150 mph(V„it=194 mph). Refer to Section 6 for Installation requirements
to meet this wind rating.
5.4.2 The GAF hip &ridge:shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and 11905.2.6.1 to ASTM.133161,Class F,indicating the shingles are acceptable for use in all wind zones up.to
Vasd=150 mph(V„it=.194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D.7158 applies only to exposure category B or C; as defined in FBC 1609.4.3, and a
meanroof height of 60 feet .or less. Calculations by a .qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
S.S All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.11 Underlayment:
6.1.1 Underlayment shall,be acceptable to GAF and shall hold current Florida Statewide Product Approval; or be
Locally Approved per Rule;61G20-3,per FBC Sections 1507:2.3,1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,.WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall'comply with:the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
Camelot,Camelot II,Grand Canyon,Grand Sequoia,Grand Sequoia IR,Grand Sequoia ArmorShield,and
Woodland require minimum five(5)nails per-shingle.
Slateline requires minimum six(6)nails per shingle.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R21
Certificate of Authorization#9503 FL10124-1119
Revision 21:08/26/2026
Page 4 of 6
TR1N1TY j ERD
63:2Fasteners shall be in.accordance with manufacturer's published requirements,but not less than.FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3:3 Where the roof slope exceeds 21 units vertical. in 12 units horizontal, special methods of fastening are
required. Contact the shingle'manufacturer for details.
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles,Seal-A-Ridge IR'Impact-Resistant Ridge Cap Shingles and Seal-
A-Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturer's current published instructions
with a minimum two(2).nails,minimum 3%8-inch head diameter,per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL S30-Roof&Flashing Sealant".
Its.: Sealant
_j7_(2,92 mm) 1° Sellante
(25 nim) (25 mm) EndW d'etancheite
* r to
- .(305 mm)
Nail
�� Claw
(.5//8't97518' Clouer
1
12°
(305 mm)
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current
published instructions with a.minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and
beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
11:5' �Ei§191Y1
(�Ia1M} {25 rYfrai �ntiuft d'�r�hdtii
i
ro� �
NOR
''� (80tatKrn�
guar
Ir
(M nim)
(305 RM)
6.43 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than 'FBC
1507.2.6 or R905.2.5. Staples are not permitted:
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1121
Certificate of Authorization#9503 FL10124-1119
Revision 21:08/26/3016
Page 5 of 6
TRINITY I ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507:2.7.1/11905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction:in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA.entity for information on which plants.produce:products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE:ENTITY:
UL LLC—QUA9625;(847)664-3281
END'OF EVALUATIONREPORT-
Exterior Research and Design,,LLC. Evaluation Report 01506.01.08-1121
Certificate of Authorization 0!9503 FL10124-1119
Revision 21:08/26/2016
Page 6 of 6
EXTERIOR RESEARCH&DESIGN,LLC.
F)o Certificate of-Authorization#9503
TR'NI-I �S p 353 CHRISTIAN STREET,UNIT#13
E(�® OXFORD,CT 06478
PHONE:(203):262-9245
FAX:(203)262-9243.
EVALUATION,REPORT
GAF Evaluation Report 01506.01.08-1121.
1 Campus Drive F1.10124-1119
Parsippany,NJ 07054 Date of Issuance:01/03/2008
Revision 21:08/26/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materialsin the State of Florida.The documentation.submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. and Florida. Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition :(2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof'Shingles
LABELING: .Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE:. This Evaluation Report is valid until such time as the named, product(s) changes, the
referenced Quality Assurance documentation changes,or provisions of the Code that,relate tothe product.change.
.Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes.. TrinitylERD requires a complete
review of this.Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation.Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,'a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by.: Cyt}tttrnpy�
f.,.�.�,\o-5°ti's• *,..
The facsimile seal appearing was authorized by Robert Nieminen;
,Robert J.M.Nieminen,P.E.. t'!�,Ss�Ou.a�c.w . P.E.ono9/26/2016.This does notserve as an electronicallysigned
s✓i�"intrn
.Florida Registration No.59166,Florida DCA ANE1983 ` ' document.Signed,sealed hardcapies have been transmitted to the
Product Approval Administrator and to the named cilent
CERTIFICATION OF INDEPENDENCE:
.1. Tr initylERD does not:have;-nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD'is not owned;operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nieminen,P.E.doe's not have.nor will:acquire,a financial'interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert.Nieminen,P.E.does:not have,nor will acquire,a financial interest in any other entity involved.in the approval process of the
,product:
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose:
TRINITY J ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing.
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/
Conditions:of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507:2.4,R905.2.3 Physical Properties A5TM D1970 2009
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1567.2.7.1,'R905.2.6.1 Wind Resistance ASTM D7158 2008
1507.2.7.1,11905.2.6:1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entitv Examination Reference Date
GAF(PDM 1915): Letter of Equivalency Seal-A-Ridge Impact Resistant:IR 01/13/2012
PRI(TST 5878) Physical Properties GAF:025-02-01 03/27/2002
PRI(TST 5818) ASTM D34621 GAF-059=02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) PhysicalProperties GAF=324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21%2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02%02/2001
UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001
UL(TST 1740) ASTM D3161 OINK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161. 03CAS367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26.444. 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23%2004
UL(TST'1740) ASTM D3161 04NK30546: 03/10/2005'
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
.UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST'1740) ASTM D3161,.D3462 06CA35251 10/1$/2006 .
UL(TST 1740) ASTM D3462` 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095: 12/27/2006
UL( TST 1740) ASTM D3161 07NK05228' 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31.7421 11/08/2007
UL(TST 1740) ASTM D3161,D7.158,D3462 08CA06100 03/13/2008
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1121
Certificate ofAuthorization#9503 FL10124-1119
Revision 21:08/26/2016
Page 2 of 6
TRINITY I ERS
gatty Examination Reference. Date
UL(TST 1740) ASTM D3161;1)3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 10CA3S554 03/05/2010
UL(TST-1740) ASTM D3161,D71M8,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010
UL(TST 1740) ASTM D3462 IOCA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D34621ONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011
UL(TST 1740) ASTM 1)3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC:(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,I.I.C.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC..(TST 9628) ASTM D3161,D7158,D3462 47868756.75 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 12/28/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,'PA 02/23/2016
UL,LLC..(QUA 9625) Quality Control Inspection Report,R2.1,Tuscaloosa,AL 02/26/2016
UL,LLC..(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 03/02/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 02/18/2016
UL,LLC.(QUA.9625) Quality Control Inspection Report,R21,Savannah;GA 02/24/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,1121,Minneapolis,MN 02/09/2016
UL,LLC.(QUA 9625) Quality'Control Inspection Report,R21,Mt.Vernon,IN 02/09/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 03/01/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 02/29/2016
UL,LLC.(QUA 9625) Quality.Control Inspection Report,R21,Dallas,.TX 02/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 02/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 03/03/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelot® II, Fortitude' , Glenwood"", Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShieldTm, Monaco®, Sienna®, Timberline® American Harvest®, Timberline®
ArmorShieldT" II,Timberline® Natural Shadow®,Timberline HD®,Timberline®.Cool Series®,Timberline Ultra
HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 Slatelihe®is a.fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2:1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge°
ArmorShieldT1 Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof'shingles.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R21
Certificate of Authorization#9503 FL10124-1119
Revision 21:08/26/2016
Page 3 of 6
TRIN1-rY j ERD
4.3 Accessory Starter Strips:
4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlockerlm Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel 8i Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less.
4.3.3 StarterMatchTm Sharter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatchTm are installed as the second starter for Grand
Canyon®and Grand Sequoia®series installations.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity,]ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of.this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section.4,1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158, Class,H, indicating the shingles are acceptable for
use in all wind zones up to Vnd=150 mph(V„it=194 mph). Refer to Section'6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified-in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to
Vamd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158•applies only to exposure category B or C as defined in FBC 1609.4.3, and a
mean roof height of 60 feet :or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 .All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C:Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule:61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
6:3 Asphalt Shingles:.
6:3:1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or 8905.2, with the following
exceptions:
Camelot,Camelot II,Grand Canyon,Grand Sequoia,Grand Sequoia IR,Grand Sequoia ArmorShield,and
Woodland require minimum five(5)nails per.shingle.
➢ Slateline requires minimum six(6)nails per shingle.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1121
Certificate of Authorization 119503 FL10124-1119
Revision 21:08/26/2016
Page 4 of 6
TRINITY I ERD
6.3.2 Fasteners shall.be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seni-A-Ridge Ridge Cap Shingles,Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-
A-Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturer's current published instructions
with a minimum two(2)nails,minimum 3/8-inch head diameter,per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL 530 Roof&.Flashing Sealant".
11.51 Sealant
1" (292 mm) 1° Sellante
125 mm) (25 mm) Enduh d'etanch&6
12'
(305 mm)
Nail
Clavo
g Sig• 7 5& Clouer
(168-194 mm)
12'
{305 mm)
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current
published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and
beads of Sonneborn NP1 Gun.Grade Polyurethane Sealant or Henkel PL.Roofing and Flashing Sealant.
1 e�laun
tl° . C2-Mtrt)' 1" ellnnrts
{�5 ta�inp (25 it�'. �nduat d"�rtan+�EUS
ar „
YzsP
(22drani)
(3{I6 tlYaaj
6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R21
Certificate of Authorization#9503 FL101247R19
Revision 21:08/26/2016
Page 5 of 6
'J"TRINITYIERD
7. LABELING:'
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/13905.2.6.1:
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA.entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1121
Certificate of Authorization#9503 FL10124-1119
Revision 21:08/26/2016
Page 6 of 6