Loading...
HomeMy WebLinkAboutProduct Approval MAX. FROM 13.O.C.MA%. MAX.FROM NAIL FIN INSTALLATION CORNERS—r—j TNRU NAIL FINCORNERS Min.Embedment 2'x4' Min. Distance MAX.16.75" o-- From Edges 3/4' O.C. O.C.Yt Min.Dlstnnee THRU FRAME From Edge-3/4' 2'x4' I/4'No 1/4' Max Shin Space Shim Space FRAME SECTION (TYP) VERTICAL SECTION Embb edmeme nt nWM-oww e.t. NAIV rwW a Wood oamap _ .3125 .125 09 1GLASS 25 BITE 0.500 ,IAMB SECTION GYP) HORIZONTAL SECTION NOTE-Cadx bele NOIW FWW t Wood OP.*0 GLAZING DETAIL UNIFORM DESIGN PRESSURE PER TAS 202 Max Frame I DP I IMPACT ' xnMDow vnmH(bz 1/e• Mo.) I/4' Max 52 1/8"x 75" +60/-65 YES Shin Space TYPICAL ELEVATI❑N WITH FASTENERS Min.Distance LMI PER TAS 201 & 203 From Edge-3/4' General Notes: tO-- • The product shown herein is designed, tested and manufactured to 2'x4' comply with the wind load criteria of the adopted International Building 1}'Min,Embedment Code (IBC), the International Residential Code(IRC), the Florida Digitally signed by Hermes F.Norero,P.E. BuildingCode including High Velocity Hurricane Zone and the indust Reason:I am approving this document g g ry Installation Notes: standard requirement for the stated conditions. 1. Seal flange/frame to substrate. Date:2014.04.24 09:50:20 04'00' • All glazing shall conform to ASTM E1300. 2. Use #10 X 1-1/2" PH or greater fasteners through'the nail fin with sufficient length • At minimum, glazing is, Laminate-1/8"Annealed Glass/.090"PVB by to penetrate a minimum of 1-1/2" into the wood framing. For two by(2X) wood DuPont/1/8"Annealed Glass or Laminate-1/8"Annealed Glass/0.090" frame substrate (Min S.G. = 0.55) Sentry Glass Plus/1/8"Annealed Glass. 3. Host structure (wood buck, stud framing and opening)to be designed and • Use structural or composite shims where required. anchored to properly transfer all loads to the structure. The host structure is the • Installation methods can be interchanged within the same opening. responsibility of the architect or engineer of record for the project of installation. • An impact protective system is not required where wind borne debris 4. Window includes a slip-on aluminum 6063-T5 nail fin with a typical wall protection is required by local building code. thickness of 0.050" and extends approximately 1.258"away from frame. • Maximum sizes are buck sizes and do not include fin or flange. %1111 I Jill This schedule addresses only the fasteners required to anchor the `�� �S F. o �j� PROJECT ENGINEER: DATE: 3737 Lakeport Blvd. product to achieve the rated design pressure and impact �� /Q i10 - 12/11/2012 jEIrD�VEN performance (where applicable) up to the size limitations noted. It ��.�'� . � RAWN BY; SCALE: Klamath Falls,OR 97601 is not intended as a guide to the installation process and does nod �� : O SI.Hertzog NTS (541)882-3451 address the sealing consideration that may arise in different wec 7 cMecKED BY: TITLE: conditions. For the complete installation procedure, see the Ar AFPROVEDBY: Premium Atlantic Single Hung Window instructions packaged with the window or go tgNail Fin Frame Installation (52-1/811 X 7511 www.jeld-wen.com/resourcesfinstallation. T T e� P OJECr No,: This drawing and its contents are the property of JELD-WEN, Inc. �, e e E�� �234A and are for the expressed use of determining anchor I qet Dan".a9ac (�vd IDENTIFIER No. PLANT NAME ANDLOCATION: CAD DWG.No.: REV: SHEET requirements for this product only. �� n} / tte 3F a �� NCTL-210-3827-1 FBC Window Division Venice NCTL210-3827-1 FBCI �� 1 of 7 x/1111111 xh Dbtonce ' F­Edge•8j' ax. FROM 20.5•O.C. MAX. M�AZS•FROM a . a• NAmNRr r �at• MASONRY INSTALLATION CORNERS}—{ iHRU FRAME CORNERS a BUXX °Q4.. ' dr- "4 9.5' 3 Eiod-nt o °O.C.MAX. d b a,e.w.et 1J' Mln, THRU FRAME Embedment v4•Mnx �RAL 1/4' Max Stile Spas '�"r Min. Hlstance Q 3 Shim Space , D d u TPoue1•r uc°n From Edge- 2k Q 2 i'.SiElSR i1lS7�eT1iN D FRAME SECTION (TYP) I(ERTICAL.SECTION D V Q � MASONRY HLOCK1 JAMB SECTI❑N (TYP) H❑RIZ❑NTAL SECTI❑N GLAZING DETAIL 4• nx UNIF❑RM DESIGN PRESSURE PER TAS 202 tiff Spee Max Frame DP IMPACT 52 1/84 x 75" +60/-65 YES wlNoow wIOTH(sz i/a• MAx.) -{ a ` ,a LMI PER TAS 201 & 203 TYPICAL ELEVATION WITH FASTENERS General Notes: a`a• ; • The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Installation Notes: Code (IBC), the International Residential Code (IRC), the Florida Building 1. Seal flange/frame to substrate. Code including High Velocity Hurricane Zone and the industry standard 2. Use 3/16"Tapcon or equivalent fasteners through frame with sufficient length requirement for the stated conditions. to penetrate a minimum of 1-1/4" into the masonry. For concrete (min fc = •—Aglazing shall conform to ASTM E1300. 3000 psi) or masonry substrate (CMU shall conform to ASTM C90). • Att minimum, glazing is, Laminate-1/8"Annealed Glass/.090" PVB by 3, Host structure (wood buck, masonry and steel) to be designed and DuPont/1/8"Annealed Glass Laminate-1/8"Annealed Glass/0.090" anchored to properly transfer all loads to the structure. The host structure is • Use structural or composite shims where required. Sentry Glass Plus/ Annealed Glass, the responsibility of the architect or engineer of record for the project of installation. • Installation methods can be interchanged within the same opening. • An impact protective system is not required where wind borne debris protection is required by local building code. • Maximum sizes are buck sizes and do not include fin or flange. ,%%lI I11//�� This schedule addresses only the fasteners required to anchor the v� S �j PROJECr ENGINEER: DATE: product to achieve the rated design pressure and impact ��� O 12/11/20RAWN BY: S12 jEL]BrWN 3737 Lakeport Blvd. „•„• • /� i - performance (where applicable) up to the size limitations noted. It �!/ •. 'p CALE: Klamath Falls,OR 97601 is not intended as a guide to the installation process and does not. ;' e •JSI•HertZog NTS (541)882-3451 address the sealing consideration that may arise in different wall 7 CM'CKEDBY: TITLE: conditions. For the complete installation procedure, see tha APPRDVEDBY: Premium Atlantic Single Hung Window instructions packaged with the window or go t( -10 T T _ www.jeld-wen.com/resourcesfinstallation. s Mason Installation 52 1 8” X 75" This drawing and its contents are the property of JELD-WEN, Inc. P olEcrNo.: ry a E�� 0234A and are for the expressed use of determining anchor ,A98;�g9tbmde•Bbac �� IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET requirements for this product only. }�' t 3 o %% NcrL-210-3827-1 W Window Division Venice NCTL210-3827-1 FBC 01 2 of 7 /111111 N.ftt—v 81 4- Fon Edge.e}• ,.,,, , MASONRY INSTALLATION MAX.FROM 20.5'O.C.MAX. MAK FROM CORNERS THRU THRU FRAME CORNERS °ad', MMAM Y ,n Fra ^�' INCLUDING SHEAR PLATE ed L4 2 a 1s.12s• v °3 Ii Nn O.C.YAX. Embedment • �Faaeawnt li' Min. THRU FRAME n Embedment 1/4' Mnx ii4•Max L67 RA1L 'Q 3 Shlm Space 4 SYam SP.M FA[ Min. Distance 4 a ALUMINUM s�PLATE From Edge, 2J' v 2 � SHEAR PLATE A FASTENER]NSTAI LATIR! „ FRAME SECTION (TYP) , VERTICAL SECTION a• ° 4 J 0 x !��� .IES ov MASONRY 95 as CLASS BLOCK 1 JAM$ SECTI❑N (TYP) 0-,W HORIZONTAL SECTION GLAZING DETAIL UNIFORM DESIGN PRESSURE PER TAS 202 Max Frame DPIMPACT 52 1/8"x 75"1+60/-65 YES -WINDOW WIDTH(52 1/e• MAX.) I d' a ? ..' LMI PER TAS 201 & 203 TYPICAL ELEVATION WITH FASTENERS d 9 General Notes: a`a BLOCK • The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Installation Notes: Code(IBC), the International Residential Code(IRC), the Florida Building 1. Seal flange/frame to substrate. Code including High Velocity Hurricane Zone and the industry standard 2. Use 3/16"Tapcon or equivalent fasteners through frame with sufficient length requirement for the stated conditions. to penetrate a minimum of 1-1/411 into the masonry. For concrete (min fc = • All glazing shall conform to ASTM E1300. 3000 psi)or masonry substrate (CMU shall conform to ASTM C90). • At minimum, glazing is, Laminate-1/811 Annealed Glass/.090" PVB by3. Host structure (wood buck, masonry and steel) to be designed and anchored DuPont/1/8"Annealed Glass or Laminate-1/8"Annealed Glass/0.09011 to properly transfer all loads to the structure. The host structure is the Sentry Glass Plus/1/8"Annealed Glass. responsibility of the architect or engineer of record for the project of • Use structural or composite shims where required. installation. • Installation methods can be interchanged within the same opening. 4. Window includes an aluminum 6063-T6 shear plate with a typical wall • An impact protective system is not required where wind borne debris thickness of 0.0625" at each anchor point. protection is required by local building code. • Maximum sizes are buck sizes and do not include fin or flange. 1111 I r r rr/l This schedule addresses only the fasteners required to anchor the /� PRO]ECr ENGINEER: DATE: ♦♦ �i -- 12/11/2012 JEIL �� 3737 Lakeport Blvd. product to achieve the rated design pressure and impact ♦ � ..•• •. J,� .•\ RAwN sY: SrALE: Klamath Falls,OR 97601 performance (where applicable) up to the size limitations noted. It ��!/ •� 'p �I,Hertzog NTS (541)882-3451 is not intended as a guide to the installation process and does not 0 address the sealing consideration that may arise in different wa� 7 CHECKED BY: TITLE: conditions. For the complete installation procedure, see theAFMOVEDBY: Premium Atlantic Single Hung Window instructions packaged with the window or go tQ -p • T T — Mason Installation 52 1 81� X 7511 vvww.field-wen.com/resources�nstallation. P o CTNo.: Masonry This drawing and its contents are the property of JELD=WEN, Inc..' and are for the expressed use of determining anchor 'qqq et bmde•amec (Hvd` � t 3 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHE requirements for this product only. p �♦ ET NCrL-210-3827-1 FBC Window Division Venice NCTL210a827.1 FBC 01 3 of 7 rrrirlel V S. 18 gauge Mn �--}—CORNERS 1THRU FRAME-�---I CO FROM 1 Steel Stud Mtr�.DEdge,LV . CORNERS From Edge, a..a•, STEEL INSTALLATION laa.fttonco 3 2 MIn.embedment Fron Eden 21' of three thread= past frone O.C.MAX. THRU FRAME 1/4•Max LIFT RAIL Shim Space PRESENT 1/4' Max Min. Distance Shim Space ALTERNATE HEMI From Edge- J' 3 2 FRAME SECTION (TMP) FASTENER IN[TAI I ATiON VERTICAL SECTION Minembedment of of three threads •,�, past frame 3123 18 gauge min 12s Steel Stud 3 .09 8 a� 125CLASS50 000 1 JAMB SECTI❑N (TYP) H❑RIZ❑NTAL SECTION GLAZING DETAIL 1/41 Max UNIF❑RM DESIGN PRESSURE PER TAS 202 Shim space Max Framel DP JIMPACT {�-WINDOW WIDTH(52 1/a'MAX.) � 52 1/8"x 75"1+60/-65 1 YES TYPICAL ELEVATI❑N WITH FASTENERS LMI PER TAS 201 & 203 General Notes: v 'stXu ua t 3 • The product shown herein is designed, tested and manufactured to comply Installation Notes: with the wind load criteria of the adopted International Building Code(IBC), the 1. Seal flange/frame to substrate. International Residential Code (IRC), the Florida Building Code including High 2. For Anchoring into metal framing, use #10 TEK self tapping screws Velocity Hurricane Zone and the industry standard requirement for the stated with sufficient length to achieve a minimum embedment of three conditions. threads past the frame thickness. Locate anchors as shown in • All glazing shall conform to ASTM E1300. elevations and installation details. Steel substrate min 18 ga.(Fy= 33 ksi). • At minimum, glazing is, Laminate-1/8"Annealed Glass/.090" PVB by DuPont/ 3. Host structure (metal framing and opening)to be designed and 1/8"Annealed Glass or Laminate-1/8"Annealed Glass/0.090"Sentry Glass anchored to properly transfer all loads to the structure. The host Plus/1/811 Annealed Glass. structure is the responsibility of the architect or engineer of record for • Use structural or composite shims where required. the project of installation. • Installation methods can be interchanged within the same opening. • An impact protective system is not required where wind borne debris protection is required by local building code. • Maximum sizes are buck sizes and do not include fin or flange %%%11111// This schedule addresses only the fasteners required to anchor the S �j PROJECT ENGINEER: DATE: Q ♦ - JELDIVEN 3737 Lakeport Blvd. product to achieve the rated design pressure and impact ® � . . i - 12/11/2012 performance (where applicable) up to the size limitations noted. It !�� •'• ..�.Fj RAwN BY: scALE: Klamath Falls,OR 97601 is not intended as a guide to the installation process and does not; ;' �� : Q �I•Her�Og NTS (541)882-3451 address the sealing consideration that may arise in different waZ 7 CWKED BY: TITLE: conditions. For the complete installation procedure, see the: ` instructions packaged with the window or go tg -p T T APPROVED BY: Premium Atlantic Single Hung Window www.jeld-wen.com/resourcesfinstallation. o ?J lV Steel Installation (52 1/8" X 75") This drawingand its contents are the properly of JELD-WEN, Inc. P O ECT No.: p p ��� a ��B'E�� ���34A and are for the expressed use of determining anchor ,8991 st 13 "bac (Bv� requirements for this product only. t 3 ` IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET 4 of 7 0 ♦ NcrL-210-3827-1 FBC Window Division Venice NCTL210.3827-1 FBC 01 1111111 IB Ba"Stud n Min.Distance run nlaa MAX.FROM 40.5•D.C. MAX. MAX.FROM 1 Steel S From Edge-JI . STEEL INSTALLATION CORNERS—I---j TNRU FRAME CORNERS INCLUDING SHEAR PLATE 3 2 MVI.embedment From Edpw Ek of three threads past frame ' O.C. MAX. THRU THRU FRAME 1/4° Max 1/4'Max LIR RAD. q sFdn Space PRESENT Shia Spnce ALUMINUM LU RNPLATE Min, Distance L(7C2 $2HEmR INUM ALTERNATE HEAD From Edgel J' PLATE FACTENER 1NCT 1 ATIDN FRAME SECTION (TYP) Min. embedment VERTICAL SECTION of three threads ,N past frame 18 gouge min 4 12s Steel Stud M _ .09 3 .125 OBITE Z 12 °'300 f JAMB SECTION (TYP) HORIZONTAL SECTION GLAZING DETAIL 1/41 Mnx UNIFORM DESIGN PRESSURE PER TAS 202 SMm Space Max Framel DP I IMPACT WINDOW WIDTH(52178' MU.) I 52 1/8"X 75" +60/—fj5 YES TYPICAL ELEVATION WITH FASTENERS ,.� LMI PER TAS 201 & 203 General Notes: v `step"stud" 3 • The product shown herein is designed, tested and manufactured to comply Installation Notes: with the wind load criteria of the adopted International Building Code (IBC), the 1. Seal flange/frame to substrate. International Residential Code (IRC), the Florida Building Code including High 2. For Anchoring into metal framing, use#10 TEK self tapping screws Velocity Hurricane Zone and the industry standard requirement for the stated with sufficient length to achieve a minimum embedment of three conditions. threads past the frame thickness. Locate anchors as shown in • All glazing shall conform to ASTM E1300. elevations and installation details.Steel substrate min 18 ga.(Fy= 33 ksi). • At minimum, glazing is, Laminate-1/8"Annealed Glass/.090" PVB by DuPont/ 3. Host structure (metal framing and opening)to be designed and 1/8"Annealed Glass or Laminate-1/8"Annealed Glass/0.090"Sentry Glass anchored to properly transfer all loads to the structure. The host Plus/1/8"Annealed Glass. structure is the responsibility of the architect or engineer of record for • Use structural or composite shims where required. the project of installation. • Installation methods can be interchanged within the same opening. 4. Window includes an aluminum 6063-7`6 shear plate with a typical wall • An impact protective system is not required where wind borne debris thickness of 0.0625" at each anchor point. protection is required by local building code. • Maximum sizes are buck sizes and do not include fin or flange. %%%%I 1111111 This schedule addresses only the fasteners required to anchor the ♦♦ s �j PROIECr ENGINEER: DATE: o , _ JE LA 3737 Lakeport Blvd. product to achieve the rated design pressure and impact ♦♦ � ...• •. , 12/11/2012 performance(where applicable) up to the size limitations noted. It ((7� RAWNBY: SCALE: Klamath Falls,OR 97601 is not intended as a guide to the Installation process and does noL :••�� ,p0 �•Hertzog NTS (541)882-3451 address the sealing consideration that may arise in different wad '7 CNECKEDBY: TITLE: conditions. For the complete installation procedure, see the' AMOVEDBY: Premium Atlantic Single Hung Window instructions packaged with the window or go tg T T Steel Installation (52 1/811 X 7511) www.jeld-wen.com/resourcesfinstallation. 41 This drawingand its contents are the roe Inc."o. OJECiNo.: property rtY of JELD-WEN, Inc. 'E�� 2 234A and are for the expressed use of determining anchor "ase st'DmISe•B (B v ao at requirements for this product only. t 3 ♦ 01 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET 5 of 7 D ♦ NCTL-210-3827-1 FBC Window Division Venice NCTL210-3827.1 FBC 1111111 B- 4" Him Distance NERSTHRU FRAME THROUGH JAMB CORO � 2 Ex MAX.FROM 1 Fron Edge•3/4' CORNERS Eon Ea INSTALLATION 2 Endnent G O.C.MAX. THRU FRAME 3 1/4' Max i�ENT 1i' Min. Slam Space Embedment ALTERNATE HEA➢ 1/4' Max FRAME SECTION (TYP) FACT R 9ffi AT1ON 3 Shim Space VERTICAL SECTION 3125 Min. Distance 125 From Edge] 3/4' 2 _ .09 GLASS •125 DITE I � QS00 JAMB SECTION (TYP) HORIZONTAL SECTI❑N GLAZING DETAIL 1/4•MaX UNIFORM DESIGN PRESSURE PER TAS 202 SNM space Max Frame DP IMPACT WINDOW WIDTH(52 1/8'MAX.)---� 52 1/8"x 75"1+60/-65 1 YES TYPICAL ELEVATION WITH FASTENERS a LMI PER TAS 201 & 203 General Notes: 1 • The product shown herein is designed, tested and manufactured to comply with Installation Notes: the wind load criteria of the adopted International Building Code (IBC), the 1. Seal flange/frame to substrate. International Residential Code (IRC), the Florida Building Code including High 2. Use #10 x 1-1/2" PH or greater fasteners through the jambs with Velocity Hurricane Zone and the industry standard requirement for the stated sufficient length to penetrate a minimum of 1" into the wood framing. conditions. For two by(2X)wood frame substrate (Min S.G. = 0.55) • All glazing shall conform to ASTM E1300. 3. Host structure (wood buck, masonry and steel)to be designed and • At minimum, glazing is, Laminate-1/8"Annealed Glass/.090" PVB by DuPont/ anchored to properly transfer all loads to the structure. The host 1/8"Annealed Glass or Laminate-1/8"Annealed Glass/0.090" Sentry Glass Plus/ structure is the responsibility of the architect or engineer of record for 1/8"Annealed Glass. the project of installation. • Use structural or composite shims where required. • Installation methods can be interchanged within the same opening. • An impact protective system is not required where wind borne debris protection is required by local building code. • Maximum sizes are buck sizes and do not include fin or flange. ��►11 ��I�� This schedule addresses only the fasteners required to anchor the ,\\ /�� PROJECT ENGINEER: DATE: 3737 Lakeport Blvd. product to achieve the rated design pressure and impact �` 12/11/2012 JELDEl� performance(where applicable) up to the size limitations noted. It !(/�.•' • •� RaWN BY: SCALE: Klamath Falls,OR 93451 is not intended as a guide to the installation process and does not: �� : O �SI•Hertzog NTS (541)882-3451 address the sealing consideration that may arise in different Wali: 7 CH'CKED BY: TITLE: conditions. For the complete installation procedure, see the FPPROVEDBY: Premium Atlantic Single Hung Window instructions packaged with the window or go t(;— T T Thru Jamb Installation (52 1/8" x 75") www.jeld-wen.com/resourcesfinstallation. P o]ECT No.: This drawing and its contents are the property of JELD-WEN, Inc. �n� n' 'E�� " h6234A and are for the expressed use of determining anchor �9get banse•Ebna (B Vd` requirements for this product only. 0, (1 t 3y� IDENTIFIER No PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET 6 of 7 �j _`Cg p \\ NCTL-210-3827-1 FBC Window Division Venice NCTL210-3827-1 FBC 00 MIM MAX. FROM 20.5.O.C.MAX. 4' t Fro Edgy n3/4' THROUGH JAMB INSTALLATION CORNERS-�--{ THRU FRAME u�AxRN QTY 3 ��,� INCLUDING SHEAR PLATE 1 2 lel'Mln. Enbednent Jew O.C.MAX. [ne w t O.C.M1/4'Max THRU FRAME 4 Shin Space LIFT WML 1J' Min. ALUMINUM Embedment1/4' Max SHEAR PLATE SHIM Space ALTERNATE HEA➢ FASTENER INSTALLATION .3 ALUMINUM FRAME SECTN (TYP) SHEAR PLATE IO VERTICAL SECTION _V a12.5 Min. Distance 2 From Edge- 3/44 N .125- BITE BITE JAMB SECTION (TYP> HORIZONTAL SECTION GLAZING DETAIL 2/14Ma>< UNIF❑RM DESIGN PRESSURE PER TAS 202 Shin Space Max Frame I EIP IMPACT 52 1/8°x 75"1+60/-65 YES wlHOow'MUM(52 1/5• YAx.) I LMI PER TAS 201 & 203 TYPICAL ELEVATI❑N WITH FASTENERS s General Notes: • The product shown herein is designed, tested and manufactured to comply with Installation Notes: the wind load criteria of the adopted International Building Code(IBC), the 1. Seal flange/frame to substrate. International Residential Code (IRC), the Florida Building Code including High 2. Use #10 X 1-1/2" PH or greater fasteners through the jambs with Velocity Hurricane Zone and the industry standard requirement for the stated sufficient length to penetrate a minimum of 1" into the wood framing. conditions. For two by(2)0 wood frame substrate (Min S.G. = 0.55) • All glazing shall conform to ASTM E1300. 3. Host structure (wood buck, masonry and steel)to be designed and • At minimum, glazing is, Laminate-1/8"Annealed Glass/.090" PVB by DuPont/ anchored to properly transfer all loads to the structure. The host 1/8"Annealed Glass or Laminate-1/8"Annealed Glass/0.090" Sentry Glass Plus/ structure is the responsibility of the architect or engineer of record for 1/8"Annealed Glass. the project of installation. • Use structural or composite shims where required. 4. Window includes an aluminum 6063-T6 shear plate with a typical wall • Installation methods can be interchanged within the same opening. thickness of 0.0625" at each anchor point. • An impact protective system is not required where wind borne debris protection is required by local building code. • Maximum sizes are buck sizes and do not include fin or flange. ,%111 1 I This schedule addresses only the fasteners required to anchor the �� S /� PROJECT ENGINEER: DATE: �� .t�� .i -- 12 11 2012 3737 Lakeport Blvd. product to achieve the rated design pressure and impact \"' ••• / / JELD�ATEN performance(where applicable) up to the size limitations noted. It �(j�.• • . � RAWNBY: SCALE: Klamath Falls,OR 97601 is not intended as a guide to the installation process and does not. �� O 711•Hertzog NTS (541)882-3451 address the sealing consideration that may arise in different wale 7 CMS KED BY: TITLE: conditions. For the complete installation procedure, see the: AMOVEDBY: Premium Atlantic Single Hung Window instructions packaged with the window or go t(£ www.jeld-wen.com/resourcesfinstallabon. wo ?J [C/ Thru Jamb Installation (52 1/811 X 751� This drawing and its contents are the property of JELD-WEN, Inc.' n' E _ %12 2 34A and are for the expressed use of determining anchor Z9KR TTanSe•abeO (B�Vd� requirements for this product only. IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET 7 of 7 t 0 %% NCTL-210-3827-1 FBC Window Division Venice NCTL21M827.1 FBC 00 T ruiirl� DO 149'MAX. OVERALL FRAME WIDTH CC HURRICANE BELLEVILLE FIBERGLASS DOOR UNIT ZOD.L.O.- PANEL WIDTH � 37.5" MAX. Q p O 6'-8"DOUBLE DOOR WITH/WITHOUT SIDELITES W/ASTRAGAL I FRAME WIDTH 0 IY c')O GENERAL NOTES 2 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO Lr)U THE FLORIDA BUILDING CODE AND WHERE PRESSURE 7n ZLr) REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM opo, w 0 I- DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, m cf3 DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. THIS PRODUCT DOES NOT REQUIRE THE USE OF A HURRICANE PROTECTIVE DEVICE (SHUTTERS). w N p 01 90 0 x 3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 � AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. a 4. PLASTICS TESTING OF FIBERGLASS FACING: TEST DESCRIPTION DESIGNATION RESULT SELF IGNITION TEMPASTM D1929 752 'F > 650'F o y RATE OF BURNING ASTM D635 0.56 IN MIN C-1 � SMOKE DENSITY I ASTM D2843 53.4% TENSILE STRENGTH- I ASTM 0638 3.2% DIFF • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 45D0 HOURS XENON ARC METHOD 1 00 0 DOUBLE DOOR UNIT W/SIDELITES Q. a Ad*Ada to NAM sn 3 V)wn 3 m fnN(n to NUl C&tJfIG3h07p1,N,0... t I-- U H8VI047Ad6y co N Date FW 29 1 ZZ V) ujo�J[na0 1313 13 ® 13 ® ® 13 ® ® 1113 1313 1313 ado N V1UJN Z W 9 0 0 0 .00 � � � � � �e .� � � �. � � � � wxJ � OZWZU0J 0 62-K) il---010 Wa Ml� SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT WISIDELITES DOUBLE DOOR UNIT W SIDELITES WITH SIDELRE WITH SIDELITE li w 0 U m x Z WHERE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE ,./ f / att[: 2 11 05 TABLE OF CONTENTS CONFIG MAX WIDTH INSWING OUTSWING INSWING OUTSWING OUTSWING* 4 ` SCAM N.T.S. SHEET # DESCRIPTION X 37.5 +70.0 -70.0 +70.0 -70.0 +19.0 -19.0 +70.0 -70.0 +70.0 -70.0 XX 74 +50.5 -50.5 +55.0 -50.5 +19.0 -19.0 +40.0 -40.0 +55.0 -50.5 DWo•U': SWS 1 TYPICAL ELEVATIONS & GENERAL NOTES OX or XO 75 t50.5 -50.5 +55.0 -50.5 +19.0 -19.0 +40.0 -40.0 +55.0 -50.5K,gr; 2 ANCHOR LOCATIONS & DETAIL 0X0 ---T12.5 +50.5 -50.5 +55.0 -50.5 +19.0 -19.0 .+40.0 -40.0 +55.0 -50.5 KURT BALTHAZOR 3 ANCHORING LOCATIONS & DETAILS OXXO 149 +50.5 -50.5 +55.0 -50.5 +19.0 -19.0 +40.0 -40.0 +55.0 -50.5 FLORIDA P.E. o "c • High Dam Threshold Design #56533 DWC-MA-FL0120-OS sxLxr 1 or 3 cc °o 6` SEE DETAIL6" 3" "Ee 3" 3" Z p J �- 3" - 3"0. I I I 11 I I I I 1I QUO 6" 6 '1� -f"6^ 6^�I- TF 4�jJ 0 Q 3 ° 10 QU In n _ — — � tU 0 W a n M Z Lr) Lu �i0)�- n SEE DETAIL V) U) Lij SEEDETAIL =o a SEE DETAIL "c, - w - .0. ` B uj o 'i ui B" 6" 6^3- 6` = °? 3 3, '1 - ` C 3" 3" 3" 3" dT6" g" o a 6` SEE DETAIL 6 `N En3 3�3}m `F` t�iiANrnInA #8 x 2-1/2" wow �uj ui ASTRAGAL RETAINER BOLT HOLE ateo <n MUST BE DRILLED THROUGH '"crit 0 a z o #10 x 2" THE THRESHOLD & INTO THE Www z 0 o #8 x 2-1/2" oozo0� STRUCTURE DEEP ENOUGH o z w o � #10 x 5/8" DETAIL "E" ASTRAGAL FOR A 1.375" THROW ATTACH ASTRAGAL RETAINER BOLT co #8 x 2-1/2" #10 x 1" STRIKE PLATE TO FRAME DETAIL 'F" ASTRAGAL o co n w o in n 00 o" Q #10 x 5/8" #10 x 1" AS SHOWN. ll NQ,,�N N.-ma p 0.124'ANNEALED DECORATIVE INSERT #10 X 2" (OPTIONAL) - t a M AddendolDNN 0.0.1 SALE%100 ko DETAIL "C" 0.124•ANNEALED 0124'TEMP. DETAIL "D" TYP. nNo.:. LL w 0 c�03x o Qg� T 2 ALUMINUM OR BUM SPACER ,�+. .•., 06% 1-1/2^PHS ".. wGe. 2111105 1 1 Dow a3z SCALE: N.T.S. 0.962• DOW 872 '�••. OR EQUAL 1 1.75" 11.047' OR EQUAL y ..L DwD.Br SWS 1.375' LE1�glpg 1NTERIO CHK.11r: T T T TYPICAL GLAZING DETAIL DRAWING NO.: INSWING THRESHOLD OUTSWING THRESHOLD HIGH DAM O/S THRESHOLD IMPACT RATED GLASS 0w0-MA-FLo120-05 SHM 2 of 3 Lo CL: Do • U O SEE DETAIL 3.. 6" "E" SHT. 2 L� -{ 3.. 6" I J— 3" 3" s" 6s s".� I I I I W O 00 6" ° + r D a 2 M N — Lo U _ Lf)N1 n W Q W a SEE DETAIL N En "D" SHT. 2 - 0 SEE DETAIL w w "C" SHT. 2 �q w I cr W B o 'n A n q v G G H B 0 o 6 in iO w z� z I -7— I I 3" I 3"-1 3"g 6" 3" AddeAdatoNM 3" SEE DETAIL 6" 6" to V)U)IL cn N 0 "F" SHT. 2 vii vii vii vii t3-vii m fie xedBy rz v DO oLo- zztiU) ATTACHMENTgTTACHMENT D�AIL 1.25w J N a o o', t. 0 25" HARDWARE SCHEDULE v 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, MAx a o 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND a SIGNED AND SEALED BY ROBERTO LOMAS, PE SHIM N z z (FLORIDA #62514) WITH THE LOWEST (LEAST) I I_ SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED o W o0 0 FASTENER RATING FROM THE DIFFERENT FASTENERS GL+ ter.: AT 5-1/2" CENTERLINE. oZzoo BEING CONSIDERED FOR USE. JAMB, HEAD, AND ^� 2. 4" X 4" FULL MORTISE BUTT HINGES. a=0 za C�5 w THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL TYPICAL MASONRY 11 o co 11, o n Lo SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR o 0 0•-w ANCHOR INSTALLATION LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". N rn N•-N 0 WOOD SCREW EDGE DISTANCE MIN 3/4". 1"X1/2" CORRUGATED /10X2" WOOD SCREW (2) dllox2-1/2" -^�aMto p' ' t 3" R0M EACH END 6" FROM EACH END WOOD SCREWS 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM 1.50" AND 7" GC AND 12" Oc EACH END ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT MIN _0MAX I —ij w o v m x z OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE SHIM ACR LAYEX MINIMUM EMBEDMENT OF 1-1/4". I CAULK DATE: 2/11/05 CL �— ACRYLIC I SCALE: N.T.S. 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO LATEX — CAULK CL .BY.. SWS TRANSFER LOADS TO STRUCTURE. ' WNK CH.9Y; 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. TYPICAL WOOD BUCK COMBINATION COMBINATION COMPOSITE DuvnHc HD.: ANCHOR INSTALLATION MULLION (BOXED) MULLION (BOXED) MULLION (INTEGRAL) DWG-MA-FL0120-05 SHEET 3 OF 3