Loading...
HomeMy WebLinkAboutProduct Approval Page 1 of 2 R E C E 1 D FEB 11 2W f` �0(; -De qflkC"I SCIS Home i Log In User Registration i Hot Topics i Submit Surcharge j Stats&Facts 1 Publications �FBC Staff j BCIS Site Map 'Links j Search j Busines PsRuApproval Profesal Public User L Regulation ppy r Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL10674-R1d Application Type Revision Code Version 2014 Application Status Approved Comments Archived .. Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL10674 R10 COI 2015 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtpgtBNbEY5V%2... 9/11/2015 Page 2 of 2 Certified By Sections from the Code Product Approval'Method Method 1 Option D Date Submitted 04/22/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Summary of Products JFL* lw-_delr Number or Name Description 10674.1 -Fowens Corning Asphalt Roo ab,5-tab,laminated,starter and hip&ridge Limits of Use_ -IShingles and Starters Installation Instructions - Approved for use in HVHZ:No FL10674 R10 11 2015 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-RI0.pd Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other- Refer to ER,Section 5. Evaluation Reports FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT SHINGLES-FL10674-RlO.Pdf Created by Independent Third Party:Yes Back Next Contact us 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an WEED employer.Cor)yrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement:;RgLund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395, 'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.IF you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts, securitv.m-,TFttcs- R�� *129 http://www.floridabuilding.org/pr/pr_apn—dtl.aspx?param--wGEVXQwtDqtBNbEY5V%2... 9/11/2015 , ' EXTERIOR RESEARCH&DESIGN,LLC. Certificate afAummization#9503 -- 363CHRISTIAN STREET,UNIT#13 UNDTY ��� OXFORD,CT 06478 \ . PHONE:(ZO3)2G2-9Z45 FAX (203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R5 One Owens Corning Parkway FL10674'R1U Toledo,OH43659 Date cfissuance:O2/0G/20i2 Revision 5: 04/22/2015 Scors: This Evaluation Report is issued under Rule 61G20'3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5'h Edition(2014)Florida Building Code sections noted herein. Dsscn/pnom: Owens Corning Asphalt Roof Shingles LAoa/ws: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. ComnmosnCoMmuAmCn This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Thnity)EODrequires acomplete review ofthis Evaluation Report relative toupdated Code requirements with each Code Cycle. Aovsnnsawswr: The Evaluation Report number preceded by the words "TrnitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. |mspscnom: UponrequestacopyofthbentireEvo|uabonReportsha(| beprnxdedtntheuserbythemanufactuerorits distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists ofpages 1through 6. Prepared by: Robert J.M.0ieminen,p.E. `�u"��=^"nw"*w�"������m��� x ^ ^c=04*2/m15.This does not serve as=electronically signed nmmmxeo�onvoowueuoanm�aDCA mvmmn ?�°'-""'� document.Signed,sealed hardco,*^have been transmitted mthe Product Approval Administrator and mthe named client CERTIFICATION opINDEPENDENCE: z. Trin)tY|ERD doe, not have, nor does itintend toacquire or will it acquire, a financial interest in any company manufacturing or distributing products itevaluates. 2. TrinitylERD is notowned,operated or controlled by anycompany manufacturing or distributing products it evaluates. ]. Robert Nieminen'P.E.does not have nor will acquire,a financial interest inany company manufacturing o,distributing products for which the evaluation reports are being issued. 4. Robert N}emmen'P.E.doe not have,nor will acquire.a Onanual interest in any other entity involved in the approval process of the product. S. This isabuilding code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any project onwhich this Evaluation Report,orprevious versions thereof,is/was used for permitting o,design guidance unless retained specifically for that purpose. ^ ^ -\ ��� ` /� U U��V �N x x (^-v^�� ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the Florida Building Code and Florida Building [ode' Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. SrAmoxnno Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 zooy 1507.23.1,R905.2.6.1 Wind Resistance ASTM 03161 zuuy 1507.2z1'x90 .za.z Wind Resistance ASTM D7158 uuno 3. Rs=snsmos: Engtiy Examination Reference Date � uLLIC(ccn96oa) Physicals mWind Resistance File n245a'Vol.a 02/15/2007 UL LLz(ccnysus) Physicals mWind Resistance 20120516-x24e3 05/16/2012 uLLLC(TST9sa) Physical Properties 06cA20263 0*/18/2006 uLLLC(TSTosao) Wind Resistance 11cA34308 02/18/2012 uLLLC(TSTeozu) Physicals&Wind Resistance 4/86093137 02/01/2014 UL Lo(TSTgoza) Wind Resistance 4786126532 02/10/2014 uLLLC(TST9ozo) Physical Properties Classification letter 02/132014 M/ami-ooue(csnxsez) ruc*v*zCompliance vanowswo^a vo,mv, UL Luc (ou^eozs) Quality Control Service Confirmation,x24as Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic*and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire^are fiberglass reinforced,4-tabasphalt roof shingles. 4.1.3 ocvonshire=are fiberglass reinforced,S-tabasphalt roof shingles. 4.1.4 Duration", TmDeOnx1o�^ Duodon^, Duration' Premium Cool, T,vop�n�ion^ Duration' Designer Color Collection,nuDe8nition'Oak�doe 'OakhdQe~andVVeatherGuo,d^HPa,efibenglas,einfboed'|aminateda,pha|tmofshingles. 42 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, weathe,Guard~ HpHip & Ridge Shingles, ProEdse Hip & Ridge Shingles and oummdge= Hip Q Ridge Shingles are fiberglass reinforced, hip and ridge asphalt mofshinDlec 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIM/nn/oms: 5.1 This isa building code evaluation. Neither Trinity|sRDnor Robert Nieminpn' p.E. are, inany way,the Designer of Record for any project uv which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Il This Evaluation Report i`not for use inthe HV*z. s.s Fire Classification/snot part ofthis Evaluation Report;refer to current Approved Roofing Materials Directory for fire ' ratings of this product. 5.4 Wind Classification: s.«.z All Owens Corning shingles noted herein are Classified in accordance with FB[Tab|es 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to V,,^=ISOmph(v,/,=l94mpk). Refer mSection 6for installation requirements tomeet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 16n7J7.1and R9O5.2.6.ztoASTM o]161'Class F,indicating the shingles are acceptable for usinall wind zones vpuo v,,^=1Snmph(V,*=194mph). Refer toSection afor installation requirements uomeet this wind rating. Exterior Research and Design,I.I.C. Evaluation Report oyryoouz.z2-ns uertiTicam*wuthorization#9503 Fu0674-nIO Revision s.u4/x2/zo1s Page zofa ` \ / U �� U JERDKU�� V 5'4.3 Classification by ASTM D7158 applies to exposure category B or C and a building heightofGOfeet u,less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific toeach shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.*`[.Rule 61G2o-3. G' INSTALLATION: 6.1 undedavmem, �1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,o,be Locally Approved per Rule*1GzO'3'per pB[Sections 15o72.3'15o7.24orn9O5.23. 6.2 Asphalt Shingles: 6.2.1 Installation ofasphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4)nails per shingle inaccordance with F8[Sections 15n72orR9OS.Z.with the following exceptions: � Berkshire"shingles require minimum five(5)nails per shingle. � VVeatherGuard^HPshingles require minimum six(6)nails per shingle. > Devonshire'"shingles require minimum six(o)nails per shingle. > Starter Strip Plus requires minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Oaoic"&5upenne: Normal Mansard or Area pore Normal Mansard or Area pare Wind Areas High Wind d"=s y Wind Areas High Wind desiniines y Area pare viontos normales Areas Viontos rt's Area pars vientos normates Areas viantos fuertes Ir Exposure r,Ilk Exposure 6.2.6 Minimum Nailing—yerksh}reO: LA tka do uW& LS dr, sobcbr Vr Exterior Research and Design,uc Evaluation Report o��02.m-RS a*vicate ofAuthorization^95a Fu0674-nIO Revision 5:04/22/201S Page a,fs r 5 TRINITY ERD 6.2.7 Minimum Nailing—Devonshire'": ,� rr ir------r-- T�Nails Nails Ten 1'Spots of Aspbalt Roof Cement 6.2.8 Minimum Nailing—Durationi",TruDefinitionO Duration, Duration'Premium Cool&TruDefinition'Duration Designer Color Collection: • lkwidaW Ship Slope 4 Nall PatterntastenMtaemsanXata EsV#ma do 4 davos Pattern �" �. anaand top olcut oLt. i4nrada epaidenrn Sump,319 bsiening am width a 8dives a¢>7SI10dw M h tt. Area declavosSul MIP • • • $a$ietnai?rtaparfe asana[hlrtab. SurrNa7a StrwaiP �_frf_f_--'f �, Eastenin4 �.. kdtl109 atnKdlA � ` aAorawi3A _241- Awda f 1 Anek S it ^it su diaip. SYi"Exposers Nass b'h"rxpasuro Si pulp.de expasi ddn clava: SrG pa1g.de exposki6n S%Exposure Nails 5V EXPusure Sii putt'.do OVO*Fon ctavos Sri puig.do arposlddn 6.2.9 Minimum Nailing—TruDefinition+Oakridge®,Oakridge®: 4 Nail Pattern 6 Nail Pattern Esguema con 4 davos EsWetna con 6 clavos r r ir 6 518"Expasuro 6 618"Exposure Nags Erposld6nde55/0pa1g davos EtposicOndo5610prdg 55ffExposu1e Claws 5SffExpmie Erpasicka de SSJSpuig Exposici6n de 5518ptdg. 6.2.10 Minimum Nailing—WeatherGuard"HP: I wooll*a&View Fig V H I Cbwm4l bowA.4fmd fJwi�w Is'ine i 1�relir Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate ofAuthorirotion 119503 FU0674-R10 Revision 5:04/22/2015 Page 4 of 6 \\ TRINITY I ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire" Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant, WeatherGuard'HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle. Installation of DuraRidgel Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturers published requirements,but not less than FBC 1567.2.6 or 8905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire"Hip&Ridge and High Ridge: Fig.1 4 Fig.2 t— PrWailkn Wind DcecionA� TOPIAM Side)Am A Naas Nails 1\\ K T Tap Lamnatat r 1 4' Piece t t 04 I t I I j j i I I I I I E>IPosue 1 ui 7 I 1 t { 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: em Fig.2 =HighWind faiswi"g Mem i4-u- KT rim Shingle—► ri_ Discard 2 E)CG r 24 SE'�a Is3 tit --► Strip T 12" 'Fast6n!hg 651x" 6"Exposure Dfistanc� 12•' 6.3.5 Minimum Nailing—WeatherGuard°HP Hip and Ridge: , Fig.C Hip&Ridge Shingle Fastening Fig.A 4 4 TopViart Pnwalinp Wind DlmOtbn p A Nails„—"'."'------y4T . A i I Nails Nails 4 \ i t T Z., �. �� t i I t Esposum Eaposuto Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 5 of 6 TRINITY ERD 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind DirectionFastening S,Int Strip Pattern A-' 6-Exposure 12, Sesisnt 1h' t Fasten 711? 76'Expasur s C= Pl F =-th Roof Comment 6.3.7 Minimum Nailing–DuraRidge"Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Dir m1n,dtiv imt on n Top View jDi rold WWrl.ro Dirved6n do]iiinto prodomijruntQ VISM;rw 0— N;uk o I N�Z� il — 4 Ulu L 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.23.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named CIA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC–QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS certificate of Authorization 89503 FL10674-RI0 Revision 5:04/22/2015 Page 6 of 6