HomeMy WebLinkAboutDrawing ize
Opening
1 15-0512-06 36 x37
(Single Hung)
2. 15-0512-06 36 x37
(Single Hung) Tt�
3. 15-0512-06 36 x62
(Single Hung)
4. 15-0512.20 26 x25
(Awing) s f
5. 15-0512.01 73 x25 Bed 1
(Horizotal Slider)
6.-15-0512.01 73 x37
(Horizotal Slider) - -
7. 15-0512.01 55 X50 - _ _ B
(Horizotal Slider) Bed 2_ _
8. 15-0512:01- - _- 55x50----
(Horizotal Slider) Bed 1'' _ --
d 2
S. 15-0512.01 55 x62 -- _ - _---- N
_(Horizotal Slider) v
M �
10. 15-0512.01 55 x 62 - - --- — - — - 4 _ _ p L„
•Lw
(Horizotal Slider) Bath y LL m
11. 15-0512.01 73 x 37
(Horizotal Slider)
Liv Rm v c �
Din Rm
10 C>1
n "
Liv Rm m
11
Liv Rm
N �
> Lo
L t)
N � M
C _
> LL
0
Kit U
ca
2 m
Kit C/)
O C
M �
r
LDPYRILRf E•TEI@EST.CAM
SCALE:
NOT TO SCALE
GATE:
+t Feb 07,2017
PAGE DESCRIPTION:
Site Plan
l� PAGE: OF7
1
III I Corporate DriveMR
0 W Boynton Beach,I!L 33426
WIN S Ph.561-922-6747.
Fax.561-292-356,2
Property Information Building' Information
Owner: Audry Rollins Wind Zone: 1 175 MPH.
Address: 13207 S Indian River Drive i Exposure Category: D
Jensen Beach FI 34957 Minimum Buildink, Dimen'sion: 49 ft.
Mean Roof Height:
Risk Category: 11
Design Pressure Calculation's
Openngl Location Device 1EDevice IFDevice Max Positive
itive
E
Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(ost) Pressure(ps�
I
End 36 37 7
48.8 -65.1
End 36 37 7 48.6
Int 36 62 7 47.2 -51.3
4 Int 26 25 7 48.6 -52.7
-5 End 73 25 7 47.9 -63.6
6 End 73 37 7 46.6 61.1
7. End 55 50 7 46.6 -61.0
61.0.
8.. End 55 50 7 46.6 -61.0
9 End .55 62 7 45.9 -59.6
End 55 62 7 45.19 -5-9.6
-L- 11 01 End 73 3)7 7 46.6 -61.1
Prepared in accordance with:liscE 7-10.Chapler 30. Wind Loads-Coillpolle,11.v(111cl Cladding.:51h Edition(2014)Florida Building Codc.
Page 1 of I
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER + TESTED DIMENSIONS MULLION REQ Y/N
( )PSF (-),PSF (+)PSF (-)PSF SIZE
REQ YIN/NA
1 End w M"LamilG 15-0512.06 70 75 48.6 65.1 5x75 36x37 N N
2 End w 7!8°LamilG 15-0512.06 70 75 _ 48.6 65.1 5x75 3607 N N
3 Int w 7,8"Lami IG 15-0512.06 70 75 47.2 51.3 53X75 36x62 N N
4 Int W 718°Lami 1G 15-0512.20 60 60 48.6 52.7 52x6 26x25 N N
5 End w '$"La"'i IG 15-0512.01 70 75 47.9 63.3 74X62 73x25 N N
6 End w 7iM"Lami IG 15-0512.01 70 75 46.6 61.1 74X62 7307 N N
7 End w 7;S°LamilG 15-0512.01 70 75 46.6 61.0 74X62 55x50 Y N
8 End W 7;3°LamilG 15-0512.01 70 75 46.6 61.0 74X62 55x50 Y N
9 End w M"Lam'IG 15-0512.01 70 75 45.9 59.6 74X62 55x62 Y N
10 End w TB"Land IG 15-0512.01 70 75 45.9 59.6 74X62 55x62 Y N
11 End w 7/8"LamilG 15-0512.01 70 75 46.6 61.1 74X62 7307 N N