Loading...
HomeMy WebLinkAboutProduct Approval 1/19/2017 Florida Building Code Online r• ` BCIS Home i Log In ( User Registration ' Hot Topics Submit Surcharge Stats @ Facts J Publications FBC Staff ` BCIS Site Map Links Search i F! rda MECEIVED Product Approval ,,, 'USER:Public User a . FES 15 2017 Product Approval Menu>Product or Application Search>Apolication List>Application Detail PERMITTING 9 � =n FL# FL16804-R1 St. Lucie County, FL Appl ication'Type Revision Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified' by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800)432-2204 Ext 4314 thoard@easternmetal.com Authorized Signature Timothy Hoard thoard@easternmetal.com Technical Representative, Timothy J. Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers, FL 33913 (800)432-22 x4 thoard@easte met c py. Quality Assurance Representative Address/Phone/Email - Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S2/A440 2005 AAMA/WDMA/CSA 101/I.S2/A440 2008 AAMA/WDMA/CSA 101/I.S2/A440 2011 ASTM E1886 2005 ASTM E1996 2009 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By https://fioridabuilding.orgtpr/pr app U.aspx?param=wGEVXQwtDgtmmTSTNdVPsciyp4ruw[9wBsOROfmKEUtGm9z4nxgVPgp/`3d`/a3d 1/3 1/19/2017 Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 07/06/2015 Date Validated 07/08/2015 Date Pending FBC Approval Date Approved 07/16/2015 Summary of Products FL# Model,Number or Name Description 16804.1 Series 143 Vinyl HR Non-Impact Fn Series 143 Vinyl HR Non-Impact Fin j Limits of Use Certification Agency Certificate Approved for use in HVHZ: No. FL16804 R1 C CAC NI011728-R3-sioned.13df Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/30/2020 Design Pressure: +50.0/-50.0 Installation Instructions I Other: Maximum Size: 72"x 60", Approved Configurations FL16804 R1 II 08-02251A.Ddf X0, OX Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes' Evaluation Reports, FL16804 R1 AE 512971A.Ddf FL16804 R1 AE Deceuninck PVC NOA 13-1203.02.PDF Created by Independent Third Party: Yes 16804.2 Series 143 Vinyl HR Non-Impact Series 143 Vinyl HR Non-Impact Flange. Flange Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL16804 R1 C CAC NI012135-signed.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/31/2018 Design Pressure: +35.0/-40.0 Installation Instructions Other:Maximum Size: 74"x 72",Approved Configurations FL16804 RI II08-02526A.pdf X0, OX Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL16804 R1 AE 513297A.12df FL16804 R1 AE Deceuninck PVC NOA 13-1203 02.PDF Created by Independent Third Party: Yes 16804.3 Series 176 Vinyl HR Impact HVHZ Series 176 Vinyl HR Impact HVHZ I Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804' RI C CAC NI012196.04-R2.PDF Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2018 Design Pressure: +70.0/-85.0 Installation Instructions Other: Maximum Size: 74"x 63", Nailing Fin or Flange, FL16804 Rl II 08-02537A.pdf Approved Configurations XO, OX Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third.Party: Yes Evaluation Reports FL16804 Rl AE 13-0328 09-COMRr)df FL16804 R1 AE 13-0328.09 Dupont SentryGlas Ddf FL16804 R1 AE 513310A.Ddf FL16804 R1 AE Deceuninck PVC NOA 13-1203.02.PDF Created by Independent Third Party: Yes 16804.4 Series 176 Vinyl HRP 1/3- 1/3- 1/3 Series 176 Vinyl HRP 1/3- 1/3- 1/3 Impact HVHZ Impact HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804 RI C CAC N1012196.01-RI.PD Approved for use outside HVHZ:Yes FL16804 RI C CAC NI012196-R2.PDF Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +65.0/-85.0 06/30/2018 Other: Maximum Size: 111"x 63", Nailing Fn or Flange, Installation Instructions Approved Configuration XOX FL16804 R1 II 08-02534A.odf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL16804 Rl AE 13-0328 09-COMP.pdf FL16804 R1 AE 13-0328.09 DuoontSentrvGlas.Ddf FL16804 R1 AE 513306A.Ddf FL16804 111 AE Deceuninck PVC NOA 13-1203.02.PDF Created by Independent Third Party: Yes https:/Ifloridabuilding.orgipr/pr app o.aspx?param=wGEVXQwtDgtmmTSTNdVPsclyp4ruwl9wBsOROfmKEUtGm9z4nxgVPg%3d%3d 213 1/19/2017 Florida Building Code Online 16804.5 Series 176 Vinyl HRP 1/4- 1/2- 1/4 Series 176 Vinyl HRP 1/4- 1/2- 1/4 Impact HVHZ Impact HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804 RI C CAC N1012196.02-RI.PDF Approved for use outside HVHZ:Yes FL16804 R1 C CAC N1012196.03-RI.PDF Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: N/A 06/30/2018 Other:Maximum Size: 111"x 63", Flange Installation Installation Instructions Design Pressure: +50.0/-65.OPSF, Nailing Fn Installation FL16804 RS II 08-02536A.Ddf Design Pressure: +55.0/-60.OPSF,Approved Configuration Verified By: luis R. Lomas, P.E. 62514 XOX Created by Independent Third Party: Yes Evaluation Reports FL16804 R1 AE 13-0328 09-COMP.pdf FL16804 R1 AE 13-0328.09 Dupont SentrvGlas.pdf FL16804 R1 AE 513308A.pdf FL16804 R1 AE Deceuninck PVC NOA 13-1203.02.PDF Created by Independent Third Party: Yes IIadc i4ext Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ®R9 �CF2CII�,G�BFt� � . , Safe httpsJ/floridabuilding.orgtpr/pr app o.aspx?param=wGEVXQwtDgtmmTSTNdVPsclyp4ruwigwBsOROfnKEUtC3m9z4nxgVPgp/*3d`/`3d 3/3 REVISIONS REV DESCRIPRON DATE APPROVED A REVISED INSTALLATION DETAILS 06/23/15 R.L. NOTES: 15. FOR FRAME ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH 1. THE PRODUCT SHOWN HEREIN AS DESIGNED AND MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT'INTO SUBSTRATE. LOCATE REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY .TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 16. FOR FRAME ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"- 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE DETAILS. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR FRAME ANCHORING INTO METAL STRUCTURE USE #10 SMS.OR SELF DRILLING SCREWS INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH SUBSTRATES WITH STRENGTHS LESS THAN-THE MINIMUM STRENGTH SPECIFIED BELOW: MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 6. WHERE 1X BUCK IS NOT USED,DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). THE ARCHITECT OR ENGINEER OF RECORD. D.. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 1/8" THICK MINIMUM 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS 20.APPROVED CONFIGURATION: XOX. PROVIDED. 21.UNITS MAY BE INSTALLED WITH OR WITHOUT FLANGE, OUTSIDE THE HVHZ. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS OPTIONS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR FIN INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE #8,WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:06/24/2015 MTMMCHECTURT sY.3 EM9 ,EaStOrn' �\1'11111JJ/�. ..um.s. arr FORTMYEOI'FIOROASlB,] TABLE OF CONTENTS SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW (1/4 — 1/2 — 1/4) 111" X 63" SHEET NO. DESCRIPTION NOTES �p� TAT QF •�t/v .. 1 NOTES DRAWN: DWG N0. 4 — 7 INSTALLATION DETAILS NTS DATE 11/17/14 60-;6 OF 7 REVISIONS 111" MAX FRAME WIDTH REV DESCRIPTION DATE APPROVED 12" A REVISED INSTALLATION DETAILS 06/23/15 R.L. 6" MAX MAX O.C. 6" MAX 6" MAX 3/16" ANN 1/8" ANN MAX O.C. / 090" SENTRY GLASS BY DUPONT 63" Y x / Y 1/8" ANN MAX O /\ EXTERIOR I INTERIOR FRAME HEIGHT GLAZING BEAD DURA—SEAL => / I SPACER SYSTEM 1/2" BITE SETTING BLOCK D SIKAFLEX 552 SEALANT GLAZING DETAIL A 6" MAX 1., SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW 3/1'6" ANN 3/16" ANN EXTERIOR VIEW FININSTALLATION .090" SENTRY GLASS BY DUPONT DESIGN PRESSURE RATING IMPACT RATING LARGE 3/16" ANN +55.01-60.OPSF MISSILE IMPACT EXTERIOR � INTERIOR MISSILE LEVEL D,WIND ZONE 4AND HVHZ GLAZING BEAD DURA—SEAL �— SPACER SYSTEM HARDWARESCHEDULE 1/2" BITE A. 4 ASHLAND DUAL KEEPERS 13999 AT FIXED MEETING STILE S"FROM HEAD&SILL o B. (4)ASHLAND DUAL LOCKS(D2300AL/R)ATSASH LOCK STILE 8"FROM SASH CORNERS C. (4)ROLLER HOUSINGS AT EACH CORNER OF SASH BOTTOM RAILS. SIKAFLEX 552 SETTING BLOCK D. (3)TRACKS AT OPERABLE SASH HEAD&SILL SEALANT GLAZING DETAIL B E. (1)ALUMINUM REINFORCEMENT(10300265)IN FIXED MEETING RAIL F. 5 ALUMINUM REINFORCEMENT 10300266 IN SASH TOP AND BOTTOM RAILS,JAMB STILES AND SASH LOCK RAI SIGNED:06/24/2015 Assrarip EASTERN EMCNRECTUMLSYSIEM9 , IJ NOTES: ASTeARto+NMErusrraY \\l\` IILQJ'f��i°. 1. MAXIMUM OPERABLE SASH SIZE: 28 1/4" X 60 1/2 u eu i°�iooMEsrwAYE �\J\•;• t't1' ! 2. MAXIMUM FIXED SASH: 57 3/4" X 60 9/16" �^"""""^""^ Pe uwi�i�iw FL0ft0A1°1° � 4\\E F' 3. MAXIMUM OPERABLE SASH D.L.O.: 25" X 57 1/16". SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW • *�'•. 4. MAXIMUM FIXED SASH D.L.O.: 50 15/16" X 58 1/4" (1/4 — 1/2 — 1/4) 111" X 63" ���''�G � 5. (2) WEEPS WITH COVER (97-03) AT SILL FACE FROM EACH CORNER. ELEVATIONS 6. (2) 1 1/2" X 1/4" WEEP SLOT AT SILL FACE 4 1/8" FROM EACH CORNER. Q• AT oF� 7. (2) 1/8" X 12" WEEP SLOT AT SILL FACE AND SILL SASH 3 1/8" FROM EACH END. DRAWN: DWG NO. co REV E► �,CORtdP \ S. (2) 1/2° X 1/8" WEEP SLOT AT SILL BEHIND GLAZING LEG. SCALE NTS DATE 11/17/14 08 50260E 7 A f/,, YONAL1 �R`\\\ REVISIONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/23/15 R.L. 111 MAX FRAME WIDTH 111 MAX FRAME WIDTH 6" MAX 10 6" MAX 6" MAX -} 6 1/2" MAX O.C. 6" MAX MAX O.C. 6"MAX 6"MAX 18" 18" Z MAX O.C. / / / MAX / / / / u 63" / 63" X O /\ MAX X O MAX FRAME FRAME HEIGHT HEIGHT 6"MAX 6"MAX SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW EXTERIOR VIEW EXTERIOR VIEW THROUGH FRAME INSTALLATION THROUGH FRAME INSTALLATION FOR MASONRY AND METAL STRUCTURE FOR WOOD FRAMING DESIGN PRESSURE RATING IMPACT RATING +50.01-65.OPSF LARGE MISSILE IMPACT MISSILE LEVEL D,WIND ZONE 4 AND HVHZ SIGNED:06/24/2015 EASTERNAR41REClURAL SYSTEMS Ea9tnr.n `�L. ,`.��� FORl-.FLORW3IBI] SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW ��� q < - (1/4 — 1/2 — 1/4) 111" X 63" r _= ELEVATIONS -'�6 AT OF LDRAWN: DWG NO. REV scAiE NTS DATE 11/17/14 08-0253650253 0E 7 A Ar REVISIONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/23/15 R.L. 1/2" MIN. I EDGE DISTANCE WOOD FRAMING OR 2X BUCK BY OTHERS 1 1/4" MIN. EMBEDMENT 1 1/4" MIN. 1/4" MAX. BACKER ROD EMBEDMENT r SHIM SPACE & APPROVED �— I INTERIOR SHIM SPACE SEALANT 1MIN. OO o 0 #10 WOOD SCREW EDGEE D DISTANCE Q o0 EXTERIOR #10 WOOD SCREW WOOD FRAMING OR 2X BUCK INTERIOR BY OTHERS BACKER ROD EXTERIOR & APPROVED SEALANT #10 WOOD JAMB INSTALLATION DETAIL u SCREW WOOD FRAMING OR 2X BUCK INSTALLATION M� O O BACKER ROD vu & APPROVED 1/4" MAX. SEALANT n r SHIM SPACE WOOD FRAMING fes' OR 2X BUCK 1 1/4" MIN. BY OTHERS EMBEDMENT 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION SIGNED:06/24/2015 WOOD FRAMING OR 2X BUCK INSTALLATION PA4 ERN MCH MION LLarS EN9 `\\\111111// Eastern METua.m. ��..5 _ rruTi IYl�iropw h v IBLt—T.— N1 N NOTES: SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW Ar�:, 'Q �`• >k_; 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, (1/4 — 1/2 — 1/4) 1 1 1" X 63" _ INSTALLATION DETAILS p CAT QF NOT SHOWN FOR CLARITY. i . ,tV` 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE RA DESIGNED IN ACCORDANCE WITH ASTM E2112 NCWN: owc No. 08-02536 RA SCALE NTS DATE 11/17/14 SHEET OF 7 REVISIONS REV DESCRIPTION DATE - PR---A REVISED INSTALLATION DETAILS 06/23/15 R.L. 3/4" MIN METAL EDGE DISTANCE STRUCTURE BY OTHERS 1/4" MAX. SHIM SPACE APPROVED SEALANT a 1/4" MAX. r SHIM SPACE j� #to SMS OR I INTERIOR LJ SELF DRILLING SCREW 3/4" MIN. EDGE DISTANCE ❑�O0 J� Q oo ® oo #10 SMS OR EXTERIOR INTERIOR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS O EXTERIOR BACKER ROD #10 SMS OR & APPROVED JAMB INSTALLATION DETAIL SELF DRILLING SEALANT METAL STRUCTURE INSTALLATION O O SCREW BACKER ROD & APPROVED SEALANT n n� 1/4" MAX. I!J u SHIM SPACE 0 METAL Q STRUCTURE BY OTHERS 3/4" MIN. EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION SIGNED:06/24/2015 E ""NARONIIEOTURILL9YHfEN9 {lllllt 6�f A.N�snNor \1S ''. Er4&gt /Y/Jt EasrenN Tft my \\\S�aj: a LQ/AA�r/'. 1ORTWEE5TFWR "R...��o...,...eo�ENS,FI➢NmAllpl] NOTES: SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW :��• p $ ' ft 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, (1/4 - 1/2 - 1/4) 1 1 1" X 63" � INSTALLATION DETAILSOF' NOT SHOWN FOR CLARITY r DESIGNED INACCORD2.PERIMETER AND INT ANCEWITHASTME2NTBY EZSTOBE EN.G. AWN: DWC N0. REV LENTS DaTE 11/17/14 08-02536sEEr50F 7 A REVISIONS REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY A REVISED INSTALLATION DETAILS 06/23/15 R.L. 2 1/2" MIN. BY OTHERS EDGE DISTANCE a 1 1/4" MIN. EMBEDMENT r 1 1/4" MIN. ` EMBEDMENT CONCRETE/MASONRY OPTIONAL 1X BUCK BY OTHERS SEE NOTES 3 - 7 n O 1/4" MAX. ° SHEET 1 Lr �J SHIM SPACE a SHIM MAX. ' ' M SPACE 3/16" TAPCON BACKER ROD 3/16" TAPCON & APPROVED SEALANT INTERIOR INTERIOROO o � EXTERIOR Q o a o ❑ ® b� 2 1/2" Q BACKER ROD MIN.EDGE a ° & APPROVED DISTANCE SEALANT aD 3/16" TAPCON EXTERIOR o JAMB INSTALLATION DETAIL 1 4" MAX. BACKER ROD CONCRETE/MASONRY INSTALLATION / OPTIONAL 1X BUCK & APPROVED OPTIONAL 1X BUCK n n� SHIM SPACE SEE NOTES 3 - 7 SEALANT SEE NOTE 3 - 7 SHEET 1 SHEET 1 NOTES: i.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. ° 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE n° 1 1/4" MIN. DESIGNED IN ACCORDANCE WITH ASTM E2112 °Q` ° EMBEDMENT SIGNED:06/24/2015 ei EASTERN MCNRECTUPAL 8Y9TEM9 1•l1I III ° Q EASTERN METAL SYPPLY ��x III Ea► tern 2°1 2" MIN. 'fy� / FORTMYERS,FLO0.mA--° EDGE DISTANCE CONCRETE MASONRY eNTAL / SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW ,�� ,r6/251 _: BY OTHERS (1/4 — 1/2 — 1/4) 1 1 1�� X 63" (y�[ VERTICAL CROSS SECTION INSTALLATION DETAILS : pT CONCRETEMASONRYINSTALLATION DRAWN: DWG NO. REV /��*(►�;��QR10P•�C�� N.G. DATE OB-02536 A SCALE NTS 11/17/14 6 OF 7 Ar REVISIONS REV DESCRIPTION DATE APPROVED APPROVED ALLTT A REVISED INSTALLATION DETAILS 06/23/15 R.L. BEHIND FIN 1 1/4" MIN. EMBEDMENT $8 WOOD WOOD SCREW FRAMING BY OTHERS 4 1/4" MAX. SHIM SPACE 7/16" MIN j EDGE DISTANCE / WOOD FRAMING � 1/4" MAX BY OTHERS SHIM SPACE U INTERIOR 1 1/4" o 0 0 EXTERIOR INTERIOR EMBEDMENT � � a aQQ #6 WOOD o0 0 SCREW EXTERIOR APPROVED7/16" MIN SEALANT EDGE DISTANCE JAMB INSTALLATION DETAIL BEHIND FIN WOOD FRAMING OR 2X BUCK INSTALLATION M�nO O 1MAX r ` 1 SHIMIM SPACE NOTES: 7/16" MIN �— 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, EDGE DISTANCE NOTSHOWN FOR CLARITY. 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE #8 WOOD WOOD DESIGNED IN ACCORDANCE WITH ASTM E2112 SCREW FRAMING 1 1/4" MIN. BY OTHERS SIGNED:06/24/2015 EMBEDMENT APPROVED FATERNARONRECURASYSTELS t1l(I1!!! SEALANTVERTICAL CROSS SECTION Eastern EASTERNNETALS PPY ``��� R LQ�/iif�. BEHIND FIN WOODFRAMINGOR2XBUCK INSTALLATION / 9 1B]�1 OOMEIITC AVE 1 �� A 1nre� unnw� iiisr! FOFLORMA]]Yl] \ Ei.s�•S./� SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW '• *• ♦0„6/25 T # (1/4 — 1/2 — 1/4) 111 X 63" INSTALLATION DETAILS TAT OF...wo � DRAWN: Dwc No. REV 08 SCALE NTS DATE 11/17/14 SHEET A /7r 76NAL( 0F 7