Loading...
HomeMy WebLinkAboutProduct Approval (2),-..0w4mg" Professional Regulation euS Home I Log In I User Registration I Hot Topics ! submit surcharge I stats & Facts I publications Fac Stall SCIS Site Map Links I search Business Professional Rea, uIation �Product Approval USER: Public User PrQdud AQuroval Menu > Product or Application Search > Application List . Application Detail FL # FL9777-117 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg-keeter@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE -74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden F' Validation Checklist - Hardcopy Received Certificate of Independence FL9777 R7 COI OCR14002 4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ - final odf Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2009 ASTM G 155 2005 TAS 103 1995 UL 1897 2004 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/19/2016 Date Validated 04/20/2016 Date Pending FBC Approval 04/21/2016 Date Approved 06/08/2016 Summary of Products FL # Model, Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL9777 R7 II OCR14002 4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ - final odf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002 4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ - f"nal odf Created by Independent Third Party: Yes 9777.2 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use In HVHZ: No FL9777 R7 II OCR14002 4A FBC 2014 Evaluation Report Approved for use outside HVHZ: Yes Impact Resistant: N/A Weatherlock Non-HVHZ - final odf Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002,4A FBC 2014 Evaluation R oor Weatherlock Non-HVHZ final - odf Created by Independent Third Party: Yes 9777.3 Weatherlock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R7 II OCR14002 4A FBC 2014 Evaluation Reporr Weatherlock Non-HVHZ - final odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE -74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002 4A FBC 2014 Evaluation R po t Weatherlock Non-HVHZ - final odf Created by Independent Third Party: Yes 9777.4 Weatherlock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL9777 R7 II OCR14002,4B FBC 2014 Evaluation R port Approved for use outside HVHZ: No Weatherlock Metal HVHZ - final Ddf Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Verified By: Zachary R. Priest PE -74021 Created by Independent Third Party: Yes Evaluation Reports EL9777 R7 AE OCR14002 4B FBC 2014 Evaluation R port Weatherlock Metal HVHZ - final odf Created by Independent Third Party: Yes 9777.5 WeatherLock Specialty Tile B Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R7 IT OCR14002 4A FBC 2014 Evaluation Report Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-105 Other: See evaluation report for limits of use. Weatherlock Non-HVHZ - final odf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R7 AE OCR14002 4A FBC 2014 Evaluation R port Weatherlock Non-HVHZ - flnal odf Created by Independent Third Party: Yes Back Neat Gonad Us :: 1940 torch Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Mond. Is an AA/EEO employer. Coevnaht 20D7-2013 State of Florida :: Pmacv Statement :: Accessibility Statement :: Refund Statement TECHNICAL SERVICES, LLC GREEK Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 5'a EDITION (2014) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19, 2016 1 Owens Corning Parkway Toledo, OH 43657 (800) 438-7465 www.owenscorning.com Manufacturing Location: Brentwood, NH Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5, 1507.4.5.2, 1507.5.3, 1507.5.3.2, 1507.7.3, 1507.7.3.2 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) NEI -039-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) NEI -042-02-01 REV2 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) NEI -045-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) NEI -045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST6049) NEI -053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) NEI -053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST6049) NEI -093-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST6049) OCF-237-02-01 UL 1897 2004 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies (TST6049) OCF-252-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies (TST5878) OCF-253-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) OCF-272-02-01 TAS 103 1995 PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock® G WeatherLock® G is an ASTM D 1970 self-adhesive undedayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2 -sq. rolls with nominal dimensions of 3 -ft x 66.7 -ft. WeatherLock® G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1 - sq. rolls with nominal dimensions of 3 -ft x 33.3 -ft and 2 sq. rolls with nominal dimensions of 3 -ft x 66.7 -ft. WeatherLock® Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002AA FL9777-R7 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers LA TECHNICAL SERVICES, LLC WeatherLock® Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3 -ft x 66.7 -ft. WeatherLock@ Metal is permitted to be used with mechanically fastened asphalt shingles, metal roof panels or shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile & Metal constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. The product is supplied in 2.14 sq. rolls with nominal dimensions of 3 -ft x 71.3 -ft. WeatherLock@ Specialty Tile & Metal is permitted to be used with mechanically fastened asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. WeatherLocke Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 (3M Company) or TILE BONDTm Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. PRODUCT APPLICATION Min. Roof Slope: 2:12 or in accordance in with FBC Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the save, starting at the eave, and with minimum 3" side laps and minimum 6" end laps staggered 6 -ft. from preceding course. End laps for WeatherLock@ Specialty Tile & Metal shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to nail the underlayment 18 -inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the undedayment). WeatherLock@ Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave. For eave protection, the underlayment should extend to a point 24 -inches inside the exterior wall. The underlayment shall be installed over metal drip edge at the eave, and under the drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install the underlayment under the drip edge in accordance Section 1507.2.9.3. Min. Application 40"F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. OCR14002.4A FL9777-R7 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 6112120-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I OWENS CORNING ROOFING AND ASPHALT LLC CREEK WeatherLock®SelfSealing Ice &Water Barriers TECHNICAL SERVICES, LLC WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlavment System No.1 Roof Deck: Min. 15/32 -inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1 -1/4 -inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1 -5/8 -inch 0 tin caps spaced 12" o.c. The applied undedayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -105 psf Pressure: GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be property ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The undedayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCR14002AA FL9777-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. .CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 5"' Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer. ,its I G\NPRY �R �iJ* No 74021 cc STATE OF '•441: OtC'A'�0RIV e -N CERTIFICATION OF INDEPENDENCE 2016.04.19 15:51:11 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002AA FI -9777-R7 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.