HomeMy WebLinkAboutProduct Approval RECEI�'�D FEB 1 '� 2D17
MI/�R°II•®�E":� MIAMI-DADE COUNTY
® ��LE COPYPRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NO'T'ICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Soprema,Inc.
1688 Jean-Berchmans-Michaud
Drummondville, Quebec J2C OC2 Canada
SCOPE
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product
Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product
or material fails to perform in the accepted manner,the manufacturer will incur the expense of such
testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material
within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION' Soprema Lastobond and Resisto Underlayment Products
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and
following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
`I'ERINIINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this
NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT.- The NOA number preceded by the words Miami-Dade County,Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0530.02 and consists of pages 1 through 7.
The submitted documentation was reviewed by Jorge L.Acebo.
NOA No.: 15-0508.04
JJP1lAP�dl•DA EE COUNTY Expiration Date: 09/29/20
e e Approval Date: 09/24/15
Page 1 of 7
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Materials: SBS
SCOPE:
This acceptance is for Soprema Lastobond and Resisto Underlayment Products as manufactured by Soprema Inc.,
as described in this Notice of Acceptance,for use with approved prepared roof assemblies as described in this Notice
of Acceptance; designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the
Florida Building Code.
TRADE NA_-mES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
Lastobond Shield 36"x 75' rolls ASTM D1970 SBS self-adhereing asphalt sheet material for use
Manufacturing Location 41 or as an underlayment for Ice Dam Protection in
45"x 75' rolls sloped roof assemblies. **Available as Lastobond
Shield 36 and Lastobond Shiled 45 for the 36"
wide and 45"wide rolls.
Lastobond Pro IIT-N 36"x 65' rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as
Manufacturing Location #1 an underlayment for Ice Dam Protection in sloped
roof assemblies.
Resisto SA Smooth Ply 40 40"x 65' rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as
Manufacturing Location 91 an underlayment for Ice Dam Protection in sloped
roof assemblies.
Lastobond Shield IIT 36"x 75' rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as
Manufacturing Location 41 an underlayment for Ice Dam Protection in sloped
roof assemblies.
Lastobond Pro HT-S 36"x 65' rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as
Manufacturing Location 41 an underlayment for Ice Dam Protection in sloped
roof assemblies.
Lastobond 195 36"x 75' rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS
Manufacturing Location #1-3 modified bitumen roofing underlayment.
Resisto LB1236 36"x 65' rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS
Manufacturing Location #1-3 modified bitumen roofing underlayment.
Resisto LB1244 44"x 75' rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS
Manufacturing Location 41-3 modified bitumen roofing underlayment.
NOA No.: 15-0508.04
i�1�,4h1�®AOE couN7Y Expiration Date: 09/29/20
e i Approval Date: 09/24/15
Page 2 of 7
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
Lastobond Eaves Protection 36"x 75' rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS
Sheet modified bitumen roofing underlayment.
Manufacturing Location #1-3
Lastobond Smooth Seal HT 36"x 65' rolls ASTM D1970 Self-adhering glass fleece reinforced, elastomeric
Manufacturing Location 91-3 bitumen roofing underlayment.
Lastobond TU IIT 39 3/8"x 65 3/5' TAS 103 and Self-adhering glass fleece reinforced, SBS
Manufacturing Location #3 rolls ASTM D 1970 modified bitumen roofing underlayment.
MANUFACTURING LOCATION:
1. Drummondville, Quebec(Canada)
2. Wadsworth, OH
3. Gulport, MS
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories, Inc. R21824 UL790 09/11/15
Trinity I ERD SOPC-SC8970.08.15 ASTM D1970/TAS 110 08/31/15
S31370.03.10-1-R1 ASTM D1970 04/07/10
S3 7210.11.11 ASTM D1970 11/09/11
S37210.12.11 ASTM D1970 12/01/11
540540.02.13-1 ASTM D1970 02/19/13
S40540.11.13 ASTM D1970 11/19/13
S43530.02.14-1-R1 TAS 103 05/14/14
S44870.04.14-4 ASTM D1970 04/10/14
S44870.04.14-1 ASTM D1970 04/10/14
S44870.04.14-3 ASTM D1970 04/02/14
S44870.04.14-2 ASTM D1970 04/02/14
S40540.10.14 ASTM D1970 10/31/14
SOPC-SC8520.04.15 TAS 103 04/27/15
NOA No.: 15-0508.04
M4AWlI•DADE COUidTY Expiration Date: 09/29/20
e e Approval Date: 09/24/15
Page 3 of 7
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Base sheet mechanically fastened,membrane adhered.
Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4"side lap and
a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the
laps and two staggered rows 12"o.c.the field of the roll.
Membrane: One ply of Lastobond Shield, Lastobond Pro HT-N, Resisto SA Smooth Ply 40,Lastobond
Shield HT, Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves
Protection Sheet, Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB 1244 with
minimum 3-inch side laps and 6-inch end laps. Starting at the first course,parallel to the
eave, align the membrane carefully by completely unrolling and setting it exactly where it
will be installed. Once aligned,rewind one half of the length. Gently score the release
paper on the high side of this roll, ensuring not to cut through the membrane's thickness.
Unroll this first half by evenly peeling back the release paper while simultaneously and
slowly pushing out the membrane. Repeat process for remaining one half of the length.
Once installed,the membrane must be pressure rolled with a metal or rubber roller. Pressure
shall be applied over the entire surface,paying particular attention to all side and end laps.
Surfacing: Approved for Mechanically Fastened Metal Roofing, Wood Shake& Shingles,Asphalt
Shingles, Slate, Simulated Slate
NOA No.: 15-0508.04
MiAMI-DADe COUNTY-M Expiration Date: 09/29/20
.e Approval Date: 09/24/15
Page 4 of 7
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32"or greater plywood or wood plank
System E(2): Base sheet mechanically fastened,membrane adhered.
Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4"side lap and
a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the
laps and two staggered rows 12"o.c.the field of the roll..
Membrane: One ply of Lastobond TU HT with minimum 3-inch side laps and 6-inch end laps. Starting
at the first course,parallel to the eave, align the membrane carefully by completely unrolling
and setting it exactly where it will be installed. Once aligned, rewind one half of the length.
Gently score the release paper on the high side of this roll, ensuring not to cut through the
membrane's thickness. Unroll this first half by evenly peeling back the release paper while
simultaneously and slowly pushing out the membrane. Repeat process for remaining one
half of the length. Once installed,the membrane must be pressure rolled with a metal or
rubber roller. Pressure shall be applied over the entire surface, paying particular attention to
all side and end laps.
The Lastobond TU HT shall be back nailed to deck with approved annular ring shank nails
and tin caps at a maximum 12"o.c. at the side laps and 6" o.c: at the end laps. No nails or
tin caps shall be exposed.
Surfacing: Approved for Mechanically Fastened Cement or Clay Roof tiles. Lastobond TU HT may be
used with any approved roof tile system adhered as specified in their current NOA using any
foam adhesive listed and having a current adhesive NOA approval.
NOA No.: 15-0508.04
Mu•D couNry Expiration Date: 09/29/20
lq�UIWe e Approval Date: 09/24/15
Page 5 of 7
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
the applicable building code. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond
Shield HT,Lastobond Pro HT-S, Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,
Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB 1244 shall be installed in strict compliance with the
applicable building code.
3. Lastobond Shield, Lastobond Pro HT-N, Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,
Lastobond TU HT, Lastobond 195, Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto
LB 1236 or Resisto LB 1244 shall be applied to a smooth, clean and dry surface, free from irregularities. Re-fasten
any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any
dust and debris prior to application. When a smooth, clean and/or dry surface cannot be obtained,the substrate
shall be primed with Elastocol Stick prior to application..
4. Lastobond Shield,Lastobond Pro HT-N, Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,
Lastobond TU HT,Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Smooth Seal HT,Resisto
LB1236 or Resisto LB 1244 shall not be applied over an existing roof membrane as a recover system but may be
applied over a roofing Base/Anchor sheet underlayment.
5. Lastobond TU HT is acceptable for use in foam adhesive set and mechanically fastened roof tile systems as
specified in the surfacing option of the approved assemblies.
6. Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT, Resisto LB 1236 or Resisto
LB 1244 shall not be left exposed as a temporary roof for longer than 30 days.
7. Lastobond Shield HT,Lastobond Pro HT-S, Lastobond Shield,Lastobond Pro HT-N and Resisto SA Smooth Ply
40 shall not be left exposed as a temporary roof for longer than 90 days of application.
8. Lastobond TU HT shall not be left exposed as a temporary roof for longer than 180 days of application.
9. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40, Lastobond Shield HT,Lastobond Pro HT-S,
Lastobond TU HT, Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Smooth Seal HT,Resisto
LB 123 6 or Resisto LB 1244 may be used with any approved roof covering listing Lastobond Shield,Lastobond
Pro HT-N, Resisto SA Smooth Ply 40,Lastobond Shield HT, Lastobond Pro HT-S,Lastobond TU HT,Lastobond
195, Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB 1244 within
the Product Approval. If Lastobond Shield, Lastobond Pro HT-N, Resisto SA Smooth Ply 40,Lastobond Shield
HT, Lastobond Pro HT-S,Lastobond TU HT, Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond
Smooth Seal HT, Resisto LB 1236 or Resisto LB 1244 is not listed, a request may be made to the Authority Having
Jurisdiction (AHJ)or the Miami-Dade County Product Control Department for approval based on the necessary
documentation to detail compatibility of the products,wind uplift resistance and fire resistance results.
10. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions. For ridge applications, center the membrane and roll from
the center outwards in both directions.
11. Membrane shall be applied to protrusions, slope changes,valley, curb, and other roof top penetration details
before any other sections of the roof.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 15-0508.04
Expiration Date: 09/29/20
1qNkAft�wi�i•�,�®e courvry P�
"'c ebKow Approval Date: 09/24/15
Page 6 of 7
13. Tiles must be staged onto Lastobond TU HT not to exceed 10-high,to the standard maximum roof pitch of 6:12
for flat tiles and 5:12 for lugged tiles. Lugged tiles staging at slope> 5:12 shall use alternate staging method
(bottom the shall be inverted followed by eight tiles high on slope, as illustrated in Figure 1 below).
I
Figure 1: Alternate Staging Method
At roof slopes greater than the preceding limitations all tiles shall be loaded onto a nominal 1"x 2"horizontal
batten to prevent slippage.
14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
QM1A1MM1-DADWEC0=UN
SEND OF THIS ACCEPTANCE
NOA No.: 15-0508.04
PHIAMI•DADE COUNTY Expiration Date: 09/29/20
e s Approval Date: 09/24/15