HomeMy WebLinkAboutpermit applicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 02/21/2017 Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
1300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772)462-15S3 Fax:(772)462-1578 Commercial Residential V
PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line
PROPOSED IMPROVEMENT LOCATION:
Address: 8268 RED CEDAR PL, PORT SAINT LUCIE, FL 34952
Legal Description: LAKE LUCIE ESTATES PLAT NO. ONE LOT 68 (OR 3220-2218).
Property Tax ID #: 3426-703-0082-000-3 Lot No. 68
Site Plan Name: Block No.
Project Name: WATER HEATER TANK CHANGE OUT
Setbacks Front Back: Right Side: Left Side
DETAILED DESCRIPTION OF WORK:
REPLACE FAILED ELECTRIC WATER HEATER TANK WITH �O GALLON AO SMITH ELECTRIC
WATER HEATER TANK LOCATED IN GARAGE.
- ONSTRUCTION INFORMATION:
niona wow to be Pertormed un ert rs permit—c ec a appy:
❑HVAC Gas Tank ❑Gas Piping _Shutters Windows/Doors
❑Electric ❑✓_Plumbing Sprinklers 11 Generator L1 Roof Roofpitch
Total Sq. Ft of Construction: 5Ft. of First Floor:
Cost of Construction:$ 1300.00 Utilities: Sewer E] Septic Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name Donna ALDRIDGE
Name: Robert W. LUDLUM
Address: 8289 RED CEDAR PL
Company: BENJAMIN FRANKLIN PLUMBING
City: PORT SAINT LUCIE State: FL
Address: 1631 SW SOUTH MACEDO BLVD
City: PORT SAINT LUCIE State: FL
Zip Code: 34952 Fax: nla
Phone No. 772-879-1964
Zip Code: 34984 Fax: 772-871-9069
E -Mail: n/a
Phone No. 772-871-9484
FIII in fee simple Title Holder on next page( if different
E -Mail: permits@benfranklinplumber.com
State or County License: CFC1426801
from the Owner listed above)
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: II
0"", U'Y cnr ctvainccn: rvuL Appucaole MORTGAGE COMPANY: _Not Applicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone: Zip: Phone:
FEE SIMPLE TITLE HOLDER:
Name:
Address:
City:
Zip: Phone: _
Not
COMPANY: _Not Applicable
Name:
Address:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie Count% makes no representation that is granting a permit will authorize the Permit holder to build the subject structure
which Is in conflict with any applicable Home Owners Association rules, bylaws or antl covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first insR2Mon. If you intend to obtain financing, consult with lender or an attorney before
COUNTYOFORIDA� /., , ytP I COUNTY OF STATE OF FLORIDAS.a q_ LZ . _ A„
The fo,,rPOing instruM99t was acknowledged before me
this fes, day of 1�7Y �' 20 aby
Ii?a�l a � • ,%r/2z
Name of person acknowledging )
Type of Iden
Commission
Revised 07/15/2014
26, 2021
The forgoing instrunnept was acknowledged before me
thisci?/ dayof OTW�' _ ,20 q_by
(Name of person acknowledging-)`
Personally KnownI YaAHDE
Type of Identification r Z.: YOOIPNISSION 0"000Bet
Commission No. , EXPIR1�11elgTary 26, 2021
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
CoSmith® Residential Electric
Water Heaters
ENHANCED HEATING ELEMENTS
• Dual 4500 watt elements for fast recovery
and reliable operation.'
• Incoloy stainless steel lower element lasts
longer than a standard copper element.
DYNACLEAN " DIFFUSER DIP TUBE
• Helps reduce lime and sediment buildup
and maximizes hot water output. Made
from long-lasting PEX cross-linked
polymer.
HIGH ENERGY FACTORS
• Eco -friendly non -CFC foam insulation,
heat traps and other features combine
to yield a higher Energy Factor that
maximizes savings on operating costs.
COREGARD'"ANODE ROD
• Our anode rods have a stainless steel
core that extends the life of the anode
rod allowing superior tank protection far
longer than standard anode rods.
BLUE DIAMOND® GLASS COATING
• Provides superior corrosion resistance
compared to industry standard glass
lining.
ENHANCED -FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid
brass, tamper resistant, enhanced -flow,
ball type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an Integral screwdriver slot that
features a 1/4 turn (open/close) radius,
which not only permits full straight -
through water flow but also a quick and
positive shot off.
-Model ENL 20 has a single anneal.
CODE COMPLIANCE
• Meets UBC and ICC National Codes and
listed with CEC.
• Complies with the Federal Energy
Conservation Standards effective
April 16, 2015, in accordance with the
Energy Policy and Conservation Act
(EPCA), as amended.
APPROVED FOR MANUFACTURED
HOUSING
• All residential electric water heaters are
compliant with HUD Standards for mobile
homes/manufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD
ELECTRIC WATER HEATERS
CSA CERTIFIED AND ASME RATED T&P
RELIEF VALVE
DESIGN -LISTED BY UNDERWRITERS
LABORATORIES
• Certified at 300 psi test pressure and 150
psi working pressure.
• Listed according to UL 174 standards
governing storage tank -type electric water
heaters.
6 -YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, Consult written
warranty or go to hotwateccom.
@0 - UL
®Mar[h 2016 A. D. smith Cr,.tion.AlI nate nsewed. Page 1 of 2
wx+v.IwM1vaterx. 1 a00-527-1953 Tell Free USA IA. O. Smith Corlwratlon 1500 Tennessee Waltz Parkway I A01and City, TN 37015 AOSHE50602
Ce Smith.
Residential Electric
Water Heaters
Model
Number
Gallon
Capacity
rstH
First Hour
Gallon
Energy
Factor
Recovery b'
90°F Rise
Gallon Per
Hour
Element Wattage 240V
Dimensions in Inches
Approx.
Weght dbsi
Standard Maximum
A B C
Tall Models
ENT -30t
30
47
0-95
21
4500
6000
46412
39-112
19
95
ENT -401
d0
51
0.95
21
i 4500
i 6000
1 601/4
1 53-114 1
20
118
ENTI
S0
10
0.95
21
1 4500
1 000
1 60-1/4
1 51 114 1
21
131
ENT -501
50
71
0.95
1 21
1 4500
1 6000
6P1/2
51le22
134
ENT -551
1 55
76
0.94
21
4500
1 6000
561/2
49112
24
1 145
Short Models
ENS B-30'
30
48
0.95
11
4500
6000
39
30-112
20
95
EEM
30
49
0.95
21
4500
6000
39-3/4
1 30-112 1
22
94
ENS -401
40
1 55
095
21
4500
6000
50
40314
20112
109
ENS -501
1 50
62
0 95
21
4500
6000
493/0
1 40all23
161
Lowboy TopCanned
Models
ENL -20
19.5
WA
N/A
21
4500
6000
30
21-t14
20
65
ENLB-30-
26
40
0.95
21
4500
6000
30
21314
22
96
ENL -301
28
43
0.95
21
4500
6000
31-114
21314
24
115
ENLB-40•
38
46
0.95
21
4500
6000
31314
24
24
118
ENL -401.
38
44
0.95
21
4500
6000
33 1R
24
26
118
ENLB-50`1
48
57
0.95
21
4500
6000
34
25
26412
IR
IASe 31S water mnne[rmni on center
'Nae els shp wfh su pp rietl ln5ula(on bled kgl
6or-. Oyear lark are 5year parts eye ants cnan9e'E m'P'I, he Earn numb,, eF,,, Ell' 30 bemme5 ENT 30)
page Far eased dol avnildMe ani,is uni
LL 11 lsa 1111, ele'nermnfgurorion ony
Oo,lonal 1pp 1&P loaalion#2 is used ontire ENT -50 ENIHSn,ENT -55,ENS -40 and ENS 50
Opl onaI top TBP Iota llon #3 6 coed on me Elect 10
Top l ftp l5 not mailable oP the IDyea,It PNLB-50.
ohne, 3e', ilraos nme,,e'v 111c It +.mtAIL' a ,..Aryo,-rt n.,apr: r Tp cmo,.
T&P VALVE
ACCESS
PANEL
ACCESS
PANEL
DRAIN
VALVE
ANODE (OR OPTIONAL
TOPT&P LOCATION #1)
OPTIONAL TOP T&P
LOCATION #3
1 t i OPTIONALTOPT&P
OO OLOCATION #2
C O OO O JUNCTION
BOX
T&P VALVE
For technical information call 800- 527 1953. A. O. Smith Corporation reserves the right o make product changes or improvements without prior notice.