NOTICE OF ACCEPTANCE (MOA) „ ,.rni:rmittadc.�i��/erom,m,
GAF J
I Campus Drive
Parsippany,N.1 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of co6struction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RLR - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Havingl,.lurisdiction (AI-IJ).
1
This NOA shall not be valid after the expiration date stated below. The Miami-Dade Ciunty Product Control
Section (ill Mianli Dade County) and/or the Al-IJ (in areas other than Mianli Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or nratc%•ial fails to perform in
the accepted maturer, the manufacturer will incur the expense Of such tCSting atld the ill-IJ may immediately
revoke, modify, or suspend the use of such product or material within their"jurisdiction. RER reserves the right to
revolve this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code. l 'I I
This product is approved as described herein, and has been designed to comply witil the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
i
DrSC12IPTION: 11u>Irh mfr et , _S, �bcrliue Natural Shadow"',and Timberli>lie Amet ican harvest
Shin;les
LABELING: Each Ullll shall beat'a permanent label willl the manufacturer's name or logo, city,slate and lollowing
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed anti there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration (late or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an cnd6rsenlent of any product.,
for sales,advertising Orally other purposes shall automatically terminate this NOA! Failureilo comply with any section
of•this NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the nlanufactui•er or its distributors and
shall be available for inspection at the.job site at the request of'tile Building Official.
This NOA revises NOA 13-0419.04 and consists of pages I through 6.
The submitted dOCUlllentali011 was reviewed by Juan E. Collao, R.A.
i
Sl
MIAMI•DADECOUtdTY j NOA No.: 14-1022.20
1 Expiration Date: 02/21/17
MEMO I Approval Date: 02/05/15
Page I of 6
,I
i
Ir
i
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Catcuorv: Asphalt Shingles
Materials: Laminate
Deck Tyne: Wood
SCOPE
This approves GAF Timberline I-B)",Timberline Natural Shadow",and Timberline Atirerican Harvest°t"
Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
A,F�1�imbeiilitiv3H�D'�'�� 13 �1.,'x 39 Glx TAS 1 l0 Fiberglass reinforced heavy weight asphalt
Manrffacluring roof shingle,with a laminate profile
Loccilions#l,2,3,4,5,6,7
GAF Timberline Natural 13 �/,4••x 39;/"• TAS 110 Fiberglass reinforced heavy weight asphalt
Shadow" roof shin�le, with'a laminate profile
MCU71I faCl uring
Locations#l,2,3,4,5,6,7
GAF Timberline American 13 39'/s "PAS 110 Fiberglass reinforced heavy weight asphalt
Har-vest'"' roofshingle, with,la laminate profile
A�Icuri fcrctur•in�T �
Localionc#2,4,5,6
I �
MANUFACTURING LOCATION
1. "Pampa, FL �
2. Michigan City, IN
3. Baltimore, MD E
4. Myerstown, PA
5. Ennis,TX
6. Tuscaloosa,AI-
7. Dallas,TX
t '
h
I'
i
i
,I
MIAMhDADEC■OUNTY
NOA No.: 14-1022.20
•• o o Expiration Date: 02/21/17
Approval Date: (12/05/15
Page 2 of 6
,
,i
i
I,
EVIDENCE SUBMITTED i
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories, Inc. ASTM D3462 I I1CA48924 10/24/11
Underwriters Laboratories, Inc ASTM D3462 IOCA21994 ; 04/22/11
Underwriters Laboratories, inc ASTM D3462 iOCA2871j7 07/26/11
Underwriters Laboratories, inc. ASTM D3462 05;CA47541 11/10/06
Underwriters Laboratories, Inc. ASTM D3462 06CA3158O 11/30/06
11111 Asphalt Technologies, Inc. ASTM D3462 GAF-101-0?-02 11/02/05
Underwriters Laboratories, Inc. ASTM D3462 O6NKO5159 4'8/09/06
PRI Asphalt Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05
llnderwriters'Liiboratories, Inc. ASTM D3462 O2NK41809 08/1 1/02
Underwriters Laboratories, inc, ASTM D3462 03Ni{26414 10/17/03
Center Ior Applied Engineering ASTM D3462 1257989! 05/13/97
Underwriters Laboratories, inc. TAS 107 0INK45803 04/13/94
Underwriters Laboratories, Inc. TAS 107 06NKO51 S9 08/09/06
Underwriters Laboratories, inc, TAS 107 04NKO4273 02/20/04
Underwriters Laboratories, Inc. TAS 107 05CA4284O 1 1/1 1/05
Underwriters Laboratories, Inc. TAS 107 02NK4181 I H/11/02
Underwriters Laboratories, Inc. TAS 107 03CA352'09 10/17/03
Underwriters Laboratories, inc. TAS 107 OCA 13 815 0 08/30/04
Center Im Applied Engineering 'f AS 100 1.257989 04/01/97
PRi Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04
PRi Asphalt`Technologies, tile, TAS 100 GAF-098-02-01 11/08/05
PRi Asphalt Technologies, inc. TAS 100 GXF-101-02-01 �� 11/09/05
PRI Asphalt Technologies, Inc. TAS 100 GAF-1 16-02-02 03/23/06
PRI Asphalt Technologies, Inc. TAS-100 EI!K-083-02-01 10/16/02
ELK-084-02-01 10/15/02
ELK-085-62-01 10/14/02
ELK-086-02-01 10/24/02
El-k-087-02-01 10/21/02
ELj;K-088-92-0i 10/16/02
E1I;K-107-02-01 10/09/03
ELK-108-,02-01 10/09/03
ELK-109,02-01 10/09/03
LIMITATIONS
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed of) rool'mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
F
�®MIAMI-DADE CCOOUNTY NOA No.: 14-1022,20
*( Expiration Date: 02/21/17
Approval Date: 02/05/15
Pale 3 of 6
1 Ii
i
I
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS I Is ;I
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
i
Shingles shall bear the imprint or identifiable marling of the manufacturer's name 61- logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved' or the Miami-Dade
County Product Control Seal as shown below.
QM1 •DADE COUNTY
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code'in order to properly
evaluate the installation of this system.
I
1i
I
I
'i
I '
'I
1
i
I
1 '
i
NOA No.: 14-1022.20
MIAMI•DADECOUNTY Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 4 of
'i
, I i
DETAIL A ;C
COURSE ]LAYOUT
i
i
i
i
I
DECK
FULL
17"OFF 4th
11" OFF 3rd
6" OFF 2nd
FULL 1 st
,i
'I
MiAMI-DADE COUNTY
I NOA No.: 14-1022.20
Expiration Date: 02/21/17
Approval Datc: 02/05/15
Page 5 ot'G
i
i
f
.i
DETAIL B
OVERALL DIMENSIONS AND MAILING PATTERN
39-3/8It j
(IM)
— 14-1/2"-17-1/2" 14-1/2"-17-112"�
(368-445mm) (368.445mm)
tt 6-1/2"-9-1/2" (-: — 6-1/2"-9-1/2" ail guide line
13-1/4 SI65.2dtmm) I 1165-�4tmm)
(33T"m) _S _� .�_ �_ (146mm-159mm)
(13.64 tf`tl from bottom of shingle
'
Self seal
adhesive
A e
on back
�I
ENHANCED NAILING PATTERN - six nails✓per shi lgle* ,!
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6"(152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be o'xposed
i
I
END OF THIS A�CIEPTANC E
.i.
I
;i
MNOA No.: 14-1022.2(!
IAMt•p�UNTY �i
• , i Expiration Date: 02/21/17
Approval Date: 02/05/15
!I Page 6 of 6