Loading...
HomeMy WebLinkAboutNotice of Acceptance r7 NIIAINII-DADE COUNTY M1AM1'QADg%" I PRODUCT CONTROL SECTION 111805 SW 26 Strect- Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami.Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(7,86)315-2590 1'(786)315-2599 NOTICE OF ACCEPTANCE (MOA) „ ,.rni:rmittadc.�i��/erom,m, GAF J I Campus Drive Parsippany,N.1 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of co6struction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RLR - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Havingl,.lurisdiction (AI-IJ). 1 This NOA shall not be valid after the expiration date stated below. The Miami-Dade Ciunty Product Control Section (ill Mianli Dade County) and/or the Al-IJ (in areas other than Mianli Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or nratc%•ial fails to perform in the accepted maturer, the manufacturer will incur the expense Of such tCSting atld the ill-IJ may immediately revoke, modify, or suspend the use of such product or material within their"jurisdiction. RER reserves the right to revolve this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. l 'I I This product is approved as described herein, and has been designed to comply witil the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. i DrSC12IPTION: 11u>Irh mfr et , _S, �bcrliue Natural Shadow"',and Timberli>lie Amet ican harvest Shin;les LABELING: Each Ullll shall beat'a permanent label willl the manufacturer's name or logo, city,slate and lollowing statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed anti there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration (late or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an cnd6rsenlent of any product., for sales,advertising Orally other purposes shall automatically terminate this NOA! Failureilo comply with any section of•this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the nlanufactui•er or its distributors and shall be available for inspection at the.job site at the request of'tile Building Official. This NOA revises NOA 13-0419.04 and consists of pages I through 6. The submitted dOCUlllentali011 was reviewed by Juan E. Collao, R.A. i Sl MIAMI•DADECOUtdTY j NOA No.: 14-1022.20 1 Expiration Date: 02/21/17 MEMO I Approval Date: 02/05/15 Page I of 6 ,I i Ir i ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Catcuorv: Asphalt Shingles Materials: Laminate Deck Tyne: Wood SCOPE This approves GAF Timberline I-B)",Timberline Natural Shadow",and Timberline Atirerican Harvest°t" Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications A,F�1�imbeiilitiv3H�D'�'�� 13 �1.,'x 39 Glx TAS 1 l0 Fiberglass reinforced heavy weight asphalt Manrffacluring roof shingle,with a laminate profile Loccilions#l,2,3,4,5,6,7 GAF Timberline Natural 13 �/,4••x 39;/"• TAS 110 Fiberglass reinforced heavy weight asphalt Shadow" roof shin�le, with'a laminate profile MCU71I faCl uring Locations#l,2,3,4,5,6,7 GAF Timberline American 13 39'/s "PAS 110 Fiberglass reinforced heavy weight asphalt Har-vest'"' roofshingle, with,la laminate profile A�Icuri fcrctur•in�T � Localionc#2,4,5,6 I � MANUFACTURING LOCATION 1. "Pampa, FL � 2. Michigan City, IN 3. Baltimore, MD E 4. Myerstown, PA 5. Ennis,TX 6. Tuscaloosa,AI- 7. Dallas,TX t ' h I' i i ,I MIAMhDADEC■OUNTY NOA No.: 14-1022.20 •• o o Expiration Date: 02/21/17 Approval Date: (12/05/15 Page 2 of 6 , ,i i I, EVIDENCE SUBMITTED i Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. ASTM D3462 I I1CA48924 10/24/11 Underwriters Laboratories, Inc ASTM D3462 IOCA21994 ; 04/22/11 Underwriters Laboratories, inc ASTM D3462 iOCA2871j7 07/26/11 Underwriters Laboratories, inc. ASTM D3462 05;CA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA3158O 11/30/06 11111 Asphalt Technologies, Inc. ASTM D3462 GAF-101-0?-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 O6NKO5159 4'8/09/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05 llnderwriters'Liiboratories, Inc. ASTM D3462 O2NK41809 08/1 1/02 Underwriters Laboratories, inc, ASTM D3462 03Ni{26414 10/17/03 Center Ior Applied Engineering ASTM D3462 1257989! 05/13/97 Underwriters Laboratories, inc. TAS 107 0INK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NKO51 S9 08/09/06 Underwriters Laboratories, inc, TAS 107 04NKO4273 02/20/04 Underwriters Laboratories, Inc. TAS 107 05CA4284O 1 1/1 1/05 Underwriters Laboratories, Inc. TAS 107 02NK4181 I H/11/02 Underwriters Laboratories, Inc. TAS 107 03CA352'09 10/17/03 Underwriters Laboratories, inc. TAS 107 OCA 13 815 0 08/30/04 Center Im Applied Engineering 'f AS 100 1.257989 04/01/97 PRi Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRi Asphalt`Technologies, tile, TAS 100 GAF-098-02-01 11/08/05 PRi Asphalt Technologies, inc. TAS 100 GXF-101-02-01 �� 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-1 16-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 EI!K-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-62-01 10/14/02 ELK-086-02-01 10/24/02 El-k-087-02-01 10/21/02 ELj;K-088-92-0i 10/16/02 E1I;K-107-02-01 10/09/03 ELK-108-,02-01 10/09/03 ELK-109,02-01 10/09/03 LIMITATIONS I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed of) rool'mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. F �®MIAMI-DADE CCOOUNTY NOA No.: 14-1022,20 *( Expiration Date: 02/21/17 Approval Date: 02/05/15 Pale 3 of 6 1 Ii i I INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS I Is ;I 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING i Shingles shall bear the imprint or identifiable marling of the manufacturer's name 61- logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved' or the Miami-Dade County Product Control Seal as shown below. QM1 •DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code'in order to properly evaluate the installation of this system. I 1i I I 'i I ' 'I 1 i I 1 ' i NOA No.: 14-1022.20 MIAMI•DADECOUNTY Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 4 of 'i , I i DETAIL A ;C COURSE ]LAYOUT i i i i I DECK FULL 17"OFF 4th 11" OFF 3rd 6" OFF 2nd FULL 1 st ,i 'I MiAMI-DADE COUNTY I NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Datc: 02/05/15 Page 5 ot'G i i f .i DETAIL B OVERALL DIMENSIONS AND MAILING PATTERN 39-3/8It j (IM) — 14-1/2"-17-1/2" 14-1/2"-17-112"� (368-445mm) (368.445mm) tt 6-1/2"-9-1/2" (-: — 6-1/2"-9-1/2" ail guide line 13-1/4 SI65.2dtmm) I 1165-�4tmm) (33T"m) _S _� .�_ �_ (146mm-159mm) (13.64 tf`tl from bottom of shingle ' Self seal adhesive A e on back �I ENHANCED NAILING PATTERN - six nails✓per shi lgle* ,! required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6"(152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be o'xposed i I END OF THIS A�CIEPTANC E .i. I ;i MNOA No.: 14-1022.2(! IAMt•p�UNTY �i • , i Expiration Date: 02/21/17 Approval Date: 02/05/15 !I Page 6 of 6 I, i