Loading...
HomeMy WebLinkAboutProduct Approval i Florida Building Code Online Page 1 of 2 I � lit BCIS Home Log In ! user Registration j Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links 'Search•� Florida {y USER:P.bucAPeroval I / Protlu[t Approval Menu>Product or Aoolicalien Search>Application Lis[>Application Detail D4 ,+ FL# FL16048-R4 Application Type Revision Code Version 2014 —. (J Application Status Approved Comments v, Archived El Product Manufacturer Tri-Built Materials Group,LLC Address/Phone/Email PO Box 70 Rutherford,NJ 07070 (800)516-1485 david.ruiz@tribuiltmg.com Authorized Signature David Ruiz david.ruiz@tribuiltmg.com �I Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford,NJ 07073 (201)842-2449 david.ruiz@tribuiltmaterialsgroup.cont Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments I I• Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer I i I C7 Evaluation Report-Hardcopy Received , I Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W.Knezevich,PE R Validation Checklist-Hardcopy Received i, i Certificate of Independence FL16048 R4 COI 2016 OS COI Nieminen odf i Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM G155 2005 FRSA/TRI April 2012(04-12) ! 2012 TAS 103 1995 Equivalence of Product Standards Certified By I Sections from the Code http://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDgtFPnidYiND Wr... 1/26/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D ri Date Submitted 10/06/2016 Date Validated 10/17/2016 Date Pending FBC Approval 10/19/2016 Date Approved 12/13/2016 Summary of Products FL# Model,Number or Name Description 16048.1 TRI-BUILT Roof Underlayments Self-adhering,mo diFed bitumen roof underlayments Limits of Use Installation Instructions ' Approved for use in HVHZ: No FL16048 R4 lI 2016 10 FINAL ER TRI- Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R4.pdf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-67.5 Created by Independent Third Party:Yes Other: 1.)The design pressure noted herein pertains to use Evaluation Reports of foam-on tile systems overtop the self-adhering FL16048 R4 AEI 2016 101 FINAL ER TRI- underlayment for one particular application.See ER Section BUILT UNDERLAYMENTS FL16048-R4.pdf 5.6.4 for details.2.)Refer to ER Section 5 for other Limits of Created by Independent Third Party:Yes Use. Back Next i Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.487.1824 The State of Florida is an AA/EEO employer.Coovriaht 2007.2013 State of Florida.::Privacy Statement:;Accessibility Statement::Refund Statement I Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However,email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: eCliul � Credit Card Safe I I i i I I I I I http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr... 1/26/2017 I' • EXTERIOR RESEARCH&DESIGN,LLC. ,Certificate of Authorization#9503 TRINITYQO �EkD 351CHRISTIAN STREET, UNIT#13 OXFORD,CT 06478 PHONE: (203) 262-9245 FAX:(203) 262-9243 EVALUATION REPORT Allied Building Products Corp. Evaluation Report A42960_10.12-R4 dba TRI-BUILT Roofing Products FL16048-114 9050 Louisiana Street Date of Issuance:10/25/2012 Merrillville, IN 46410 ' Revision 4: 10/06/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules Ind regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate ito the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requirles a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall b "'done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the fuser by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: s)NQgrr4rp,— r,i Robert J.M.Nieminen,P.E. ThefacsimilesealappearingwasauthorizedbyRobertNleminen, Florida Registration No.59166,Florida DCA ANE1983 ,, P.E.on 10/06/2di6.This does not serve as an electronically signed �' document.signed,sealed hardcopies have been transmitted to the Pri uct Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financiall interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distrjbuting products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 1 j 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nleminen, P.E. are, in any way,the Designer of Record for any project On which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. I d i I I ill I �TRINFF(IERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated compliance with the following sections of the Florida Building Code through testing in accIordance�with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009 1507.4.5.1,1507.5.3,1507.7.3 1504.6 Accelerated Weathering ASTM G155 2005 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties S40540.11.13 11/19/2013 ERD(TST6049) Physical Properties S40540.03.14 03/26/2014 ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014 . ERD(TST6049) Physical Properties S44870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties S43530.02.14-1-111 ;,i 05/14/2014 ERD(TST6049) Physical Properties S43530.05.14 05/28/2014 ERD(TST6049) Physical Properties 540540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 UL,LLC.(QUA9625) Quality Control Multiple-Listing 1116814 09/04/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering-Underlayments: 4.1.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric'surfaced, SBS modified bitumen roof underlayment 4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity{ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current,Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R4 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Iii FL16048-R4 Revision 4:10/06/2016 ! Page 2 of,5 'I i s it I i i, TRIM-ry I ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof ;cover where the product is, specifically referenced within FBC approval documents. If not listed a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering- 5.5 Allowable roof covers applied atop the underlayments are as follows: I, TABLET ,R.d&COVER!OPTIONS, k ,,,, t, =,1 Underlayment Asphalt' Nall-On Tile Foam-On Tile Metal Wood Shakes Slate Shingles &Shingles, Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri-Built S/A HTTU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. {• ➢ Tri-Built 5/A HT TU Underlayment with 3M11" 2-Component Roof Tile Adhesive AH-160 (FL6332) or Dow TileBondTm Roof Tile Adhesive(FL717) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ;? Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed)OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. l While not required over plywood, OSB or Southern Yellow Pine substrates, T,RI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. i 5.6.2 Bond-to-Insulation: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation, shall be attached per. minimum requirements of the prepared roof covering manufacturer' s Product Approval. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed iby a.qualified design professional and installed based on-testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Apper dix J. 5.6.3 Bond to Mechanically Attached Base Layer: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). Exterior Research and Design,LLC. „lEvaluation Report A42960.10.12-R4 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL16048-R4 Revision 4:10/06/2016 Page 3 of 5 i .III 1� T' TiRIN ITY ERD 5.6.4 Wind Resistance for Underlavment Systems in Foam-On Tile Applications:I,FRSA/ITRI April 201.2 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-;on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck underfayment systems that are not addressed in FRSA/TRI April 2012(04-121)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing,pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures: l � 5.6.4.1 Maximum Design Pressure=-45.0 psf° Deck: 'Min.15/32-inch plywood to meet project requirements to;satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: Tri-Built S/A HTTU Underlayment,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: Soprema Elastocol 600c Underlayment: Tri=Built S/A HTTU Underlayment,self-adhered, 5.6.4.3 Maximum Design Pressure=-60.0 psf. {; Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps(FBC 1517.5.2)spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c, in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HTTU Underlayment,self-adhered. 5.7 Exposure Limitations: 5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT'S/A, Underlayment shall not be left exposed for longer than 30-days after installation jJ 5°7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. tt 6. INSTALLATION: I' 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance.with TRI,-BUILT, published installation requirements subject to the Limitations set forth in Section 5 herein, and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate!(if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlavment,Tri-Built S/A HT TU Underlavment or Tri-Built Smooth HT S/A Underlavment• 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970;underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. l j 6.3.2 Non-Tile applications: While priming is optional,TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membraine as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll,broom or hand-press the membrane into place'to achieve a bond. i. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course bellow,sealed in accordance with TRI-BUILT requirements. �I Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-114 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION F1.16048-114 I; Revision 4:10/06/2016 ! Page 4 of 5 i, i I� I TRINITY ERD When installing at slopes above 8:12,TRI-BUILT recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut-underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HT TU Underlayment only): Reference is.made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted CIA agency for information on product locations covered for F.A.C.Rule 9N-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- li I I'I, i' I I Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R4 Certificate of Authorization 119503 FBC NON-HVHZ EVALUATION F1.16048-114 Revision 4:10/06/2016 Page 5 of 5 I P 'I I• 'n MIANI1-DADE COUNTY MIAMI•DADE) j PRODUCT,CONTROL SECTION 11805 SW 26 Street, Room 209 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Mi mi.Florida 33175-247,1 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-259017(786)315-2599 NOTICE OF ACCEPTANCE (NOA) �'„.�»i:.midadc. ,I,/crone,,,, GAF I I Campus Drive Parsippany,NJ 07054 SCOPE: I ' This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miarni-Dade County RLR - Product Control Section to he used in Miami Dade County and other areas where allowed by the Authority Flavin` .lurisdi'ction (AH.l). This NOA shall not be valid after the expiration date stated below. The Miami-(Dade County Product Control Section (In Miami Dade County) and/or the A14J (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material tails to perform in the accepted manner, the manufacturer will incur the expense of' such testing alnd the AFIJ niay immediately revolve, modify, or suspend the use of such product or material within their,jurisdiction. RER reserves the right to revolve this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. his product is approved as described herein,and has been designed to comply with the Florida 136ilding Code including the I-figh Velocity Hurricane Zone of the Florida Building Code. I)LSCltll'TION: (:ASI C+iRrb�xriliric`,ii411D),Timberline Natural Shadow° and Timberline Am rican Harvest Shingles LABELING: L'aeh unit shall bear a permanent label Willi tile manufacturer's nam or logo;•city,stale and following statement: Miami-Dade County Product Control Approved”, unless otherwise noted hereini: RENEWAL of this NOA shall be considered after a renewal application has been(filed and;there,has been no change in the applicable bnlldnlg code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a red<ision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA ,is an end6rsement of any product, For sales, advertising orally other purposes shall automatically terminate this NOA�. Failure to conipiv with any section of this NOA shall be cause for termination and removal of'NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, r1lorida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at.the.job site at the request of'the Building Official. This NOA revises NOA 13-0419.04 and consists of pages I through G. The submitted documentation was reviewed by Juan E. Collao, R.A. 7 � iAaer NOA No.: 14-1022.20 MIAMI•DADECOUNTY I I'' Expiration Date: 02/21/17 r / Approval nate: 02/05/15 t,, ; Page I of 6 ROOFING ASSEMBLY APPROVAL Category: Rooting ?` Sub-Catertiory: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HDA',Timberline Natural Shadow"'",and Timberline Anicau Hat-vest Shingles as manufactured by GAF as described in Section '-2 of this Notice of Acceptance . PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications G F Timberline HD'"' 13 '/,I 1 39;/x• TAS 1 10 Fiberglass i rc utfarced beau weight asphalt b Y 1 Mal nfac lirul9 roof shingle, with,it laminate profile Localions#1,2,3,4,5,6,7 GAF Timberline Natural 13s 39;/ TAS 1 10 Fiberglass reinfore'ed heavy weight asphalt Shadow'' roof shingle,with''a laminate Iarotilc MancrfucRn•ing Localions#1,2,3,4,5,6,7 GAF Timberline Amc•ic n 13 /,I x 39'/H' 'I'AS 110 Fiberglass reinffi ced heavy weight asphalt Harvest-' roof shingle,witli�a laminate profile A�Ianufcrcluring i ' Locutions#2,4,5,6 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN ?' 3. Baltimore, MD '• 4. Myerstown, PA &, 5. Ennis,"fX C>. Tuscaloosa,AL 7. Dallas,TX I, ;.I MIQMI•DADE COUNTY i NOA No.: 14-1022.20 e ,I Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 2 of 6 r� E P'I EVIDENCE SUBMITTED 44' Test Agency Test Identifier I est NanIC/I2ci)Urt Date Underwriters Laboratories, Inc. ASTM D3462 1 ICA489,24 10/24/11 Underwriters Laboratories, Inc ASTM D3462 IOCA21994 04/22/( 1 Underwriters Laboratories, Ine ASTM D3462 1 6CA2871 7 07/26/11 Underwriters Laboratories, Inc. ASTM D3462 OkA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 OkA315`80 11/30/06 PRI Asphalt,Technologies, Inc. ASTM D3462 GAFF-101-42-02 11/02/05 Underwriters;Laboratories, Inc. ASTM D3462 OGNK051,5'9 08J09/06PRI Asphalt Technologies, Inc, AS"I'M D3462 GnF -098-0?-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories, Inc, ASTM D3462 6N K264,44 10/17/03 Center for Applied Engineering ASTM D3462 257984, 05/13/97 Underwriters Laboratories, Inc, TAS 107 QINK458103 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, Inc. TAS 107 014NK04273 02/20/04 Underwriters Laboratories, Inc. TAS 107 05CA428140 1 1/1 1/05 Underwriters Laboratories, Inc. TAS 107 0,2NK419,1 1 1 1/1 1/02 1 ' Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories, file. TAS 107 04C 13850 08/30/04 Center for Applied Engineering TAS 100 25798;0, 04/01/97 PRI Asphalt`Technologies, Inc. TAS 100 GA F-044-9"2-01 01/13/04 PRI Asphalt Technologies, Inc, "TAS 100 GIF-098-02-01 11/08/05 PRI Asphalt Technoiogies, Inc. TAS 100 GAj F-101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-1 16-62-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 F11 K-083-62-01 10/16/02 ELI K-084-"62-01 10/15/02 E11,K-085-02-01 10/14/02 EI;K-086-x02-01 10/24/02 ELK-087-,Q2-01 10/21/02 ELK-088 tl02-01 10/16/02 ELK-10702-01 10/09/03 ELK-108=02-01 10/09/03 ELK-109102-01 10/09/03 1LIMITATIONS 'i 1. Fire classification is not part of this acceptance; refer to a current Approved Rooting Materials Directory for fire ratings of this product. ;1, 2. Shall not be installed on roof►Wean heights in excess of 33 ft. +' 3. All products listed herein shall have a quality assurance audit in accordance with the"Florida Building Code and Rule 61G20-3 ofthe Florida Administrative Code. fl 1� it ,a i• NOA No.: 14-1022.20 MIAMI•bAbE CCIUNTY "�' lowExpiration Date: 02/21/17 �I Approval Date: 02/05/15 Page 3 of 6 •1 i INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Stanclard RAS 1'15. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W, attached 5. Nailing shall be in compliance with Detail '13', attached. LABELING Shingles shall bear the imprint or identifiable marking ol' the manufacturer's name 'or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. �MIAM�I-DADE�COUN�TY BUILDING PERMIT REQUIREMENTS " 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable' cocle in order to properly evaluate the installation of this system. i i. i i NOA No.: 14-1022.20 MIAMI-DADEC(, Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 4of6 I y d ,I DETAIL A COURM)LAYOUT �1 l 1 `i AI ,i i !i DECK i t� 1i FULL 5th 17" OFF 4th 11"OFF 3rd 6" OFF 26d ,i FULL i 1 st i� j l ;j NOA No.: 14-1022.20 MIAMI•DA®U NrYExpiration Date: 02/21/17 Approval Datc: 02/05/15 Page 5 of 6 �s i DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN I 39(3/8" -�— 14-1/2"-17-1/2" 14-1/2"-17-1/2" (368-445mm) (368.445mm) ail guideline _� ft 6-1�cs.ia9im1>12 6-1/25,z91t/2 5-314"-6-114" 13337 i,n�4 — — — — — — — — {146mm-159rnm) TO'-z_T/2• from bottom of shingle 117-W li, SeIf seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm) from bottom'of of shingle, above the cut outs, as shown. Nails must not be exposed;. END OF THIS ACCEPTANCE NOA No.: 14-1022.20 QMIAMMIMADEOUNTY I' Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 6 or 6 .;i