Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 J. 44 @1 ` e Y 11 y W11 + BCIS Home Log In user Registration Hot Topics Submit Surcharge I Scats&Facts Publications FBC!Staff BCIS Site Map Links Search dbpr a Product Approval Brei USER:Public User o:yt.mt ry A Product Aooroval Menu>Product or Aoolication Search>Application List>Application Detail ' •�; FL# FL16048-R4 � l Application Type Revision ` I Code Version 2014 Application Status Approved �� t Comments Archived ❑ _ Product Manufacturer Tri-Built Materials Group,LLC i Address/Phone/Email. PO Box 70 Rutherford, NJ 07070 " (800)516-1485 david.ruiz@tribuiltmg.com Authorized Signature David Ruiz david.ruiz@tribuiltmg.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford, NJ 07073 (201)842-2449 david.ruiz@tribuiltmaterialsgroup.com! Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer l7 Evaluation Report-Hardcopy Received i Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W.Knezevich,PE 1,46 Validation Checklist-Hardcopy Received Certificate of Independence FL16048 R4 C01 2016 0!1 C01 Nieminen.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM G155 2005 FRSA/TRI April 2012(04-12) 2012 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pI_app_dtl.aspx?param=wGEVXQwtDgtFP'indYiND Wr... 1/26/2017 ;i Florida Building Code Online Page 2 of 2 i Product Approval Method Method 1 Option D Date Submitted 10/06/2016 Date Validated 10/17/2016 Date Pending FBC Approval 10/19/2016 Date Approved 12/13/2016 Summary of Products I FL# Model,Number or Name Description I, 16048.1 TRI-BUILT Roof Underlayments Self-adhering,modified bitumen roof underlayments Limits of Use Installation Instructions!' Approved for use in HVHZ:No FL16048 R4 11 12016 10'FINAL ER TRI- Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-124.pcif Impact Resistant:N/A Verified By: Robert Nieminen PE-59',166 Design Pressure: +N/A/-67.5 Created by Independent Tliird Party:Yes Other: 1.)The design pressure noted herein pertains to use Evaluation Reports of foam-on tile systems overtop the self-adhering FL16048 R4 AE 2016 10 FINAL ER TRI- underiayment for one particular application.See ER Section BUILT UNDERLAYMENTS FL16048-R4.pdf 5,6.4 for details.2,)Refer to ER Section 5 for other Limits of Created by Independent Third Party:Yes Use. Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 I The State of Florida is an WHO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florlda law,email addresses are public records.If you do not want your e-mail address released in response'to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850,487.1395.-Pursuant to. Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made ava lable to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe . II i I„ I I,I i I i I http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr... 1/26/2017 I EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization 119503 TRINM(I 353 CHRISTIAN STREET, UNIT #13 QOERD OXFORD,CT 06478478 PHONE: (203) 262-9245 FAX:(203)-262-9243 EVALUATION REPORT Allied Building Products Corp. Evaluation Report A42960.10.12-R4 dba TRI-BUILT Roofing Products FL16048-R4 9050 Louisiana Street Date of Issuance:10/25/2012 Merrillville, IN 46410 Revision 4: 10J06/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted hasi been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building .Code, Residential Volume. The products described herein have been evaluated for compliance with the 5 lhEdition (2014) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling, shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the,product change. Acceptance.of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJ ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be,done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the,user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by:000 = S7 IQ !r,�Sc' "Cr-0� i Robert J.M.Nieminen,P.E. L;,r„y ��LQss.,� The facsimilesealappearingwas authorized by.RobertNieminen, r,�, tt,pd P.E.on 10/06/2016.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 r` document.Signed,sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. ! 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial Interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinitv]ERD.nor Robert Nleminen, P.E. are,�in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose, I� ��,. TRINITYIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments,as produced byTRIiBUILT,have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4,1507.2.8;1507.2.9.2, Physical Properties ASTM D1970 2009 1507.4.5.1,1507.5.3,1507.7.3 1504.6 Accelerated Weathering ASTM G155 2005 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties S40540.11.13 11/19/2013 ERD(TST6049) Physical Properties S40540.03.14 03/26/2014 ERD(TST6049) Physical Properties S44870.04.14-2 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties 543530.02.14-1-R1 05/14/2014 ERD(TST6049) Physical.Properties 543530.05.14 05/28/2014 ERD(TST6049) Physical Properties 540540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 UL,LLC:(QUA9625) Quality Control Multiple-Listing R16814 09/04/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Self-AdherlwUnderlayments: 4.1.1 Tri-Built Sand-R SA Shingle Underlayment is a self_adhering, .glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment 4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD no, Robert Niemiiien, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retainedspecifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. i 5.3 Fire Classification is not part of this Evaluation Report; refer ti current.Approved Roofing Materials Directory for fire ratings of this product. i Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R4 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL16048-R4 Revision 4:10/06/2016 Page 2 of 5 i r'! I I ' '\S- TRINITY I ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed 1 a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering- 5.5 Allowable roof covers applied atop the underlayments are as follows: „TABLE•1:'ROOF•60VER.OB,T10 S Underlayment Asphalt Nall-On Tile Foam-On Tile Metal Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No i Yes Yes Underlayment Tri-Built S/A HTTU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A TYe, No No Yes YesYes Underlayment 5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Tri-Built S/A HT TU Underlayment with 3M'"" 2-Component Roof Tile Adhesive AH-160 (FL6332) or Dow TileBond'"Roof Tile Adhesive(FL717) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Tri-Built Sand;R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. I While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires tongue-and-groove board decking be covered with plywood .or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Tri-Built Sand=R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Trl-Bulla Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment Ionly), insulation attachment shall be designed'by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. 5.6.3 Bond to Mechanically Attached Base Laver: Tri-Built Sand-111 SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer'shall be attached per minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04- 12). Exterior Research and Design,LLC: 'Evaluation Report A42960.10.12-R4 Certificate ofAuthaNzatlon 09503 FBCGNON-HVHZ EVALUATION F1.16048-114 Revision 4:10/06/2016 Page 3 of 5 i TRINITY ERS 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications:,i;FRSA/TRI April 2022 (04-12) does not address wind uplift resistance of all underlayment systems beneath,ifoam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to d irect-deck underlayment systems that are not addressed in FRSA/TRI April 2012(04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load' resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by,2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6.4.1. Maximum Design Pressure=-45.0 psf. Deck: Min.15/327inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.6.4.3 Maximum Design Pressure=-60.0 psf. Deck: .Min.19/32-inch plywood to meet project requirements to;satisfaction of AHJ. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1) and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the.center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered 5.7 Exoosure•Limitations: 5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed'for longer than 30-days after installation 5.7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance•with TRI'-BUILT published installation requirements subject to the Limitations set forth in Section 5 here: ,and the'specifics noted below. 6.2 Re-fasten any'loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate,(if applicable). 6.3 Tri-Built Sand=R SA Shingle.Underlayment,Tri-Built S/A HT TU'Unl erlayment or Tei-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 dnderlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile applications: While priming is optional,TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film,diagonally while,holding the membrane tight. Firmly roil,broom or hand-press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water: Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with TRI-BUILT requirements. Exterior Research and Design,I.I.C. ;Evaluation Report A42960.10.12-114 Certificate of Authorization#9503 FBC.NON-HVHZ EVALUATION FL16048-114 Revision 4:10/06/2016 Page 4 of 5 li ! TRINITY I ERD When installing at slopes above 8:12,TRI-BUILT recommends,back,nailing in-the overlap area at the top of the sheet at 12-inch o.c. it For Valleys.and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper-and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,:apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built 5/A HT TU Underlayment only): Reference is made to •FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile .slippage and/or damage to the underlayment. I 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8.- MANUFACTURING PLANTS: Contact the noted OA agency for information on product locations covered,for F.A.C.Rule 9N-3 QA requirements. I 9. QUALITY ASSURANCE-ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- , i I ' "I it I I'I • I I '.I I 11 I I Exterior Research and Design,I.I.C. I Evaluation Report A42960.10.12-R4 Certificate ofAuthortratlon#9503 FBC NON-HVHZ EVALUATION ;I FL16048-R4. Revision 4:10/06/2016 li Page 5 of 5 i I i t-��', NIIAMI-DADS COUNTY MIAMhI?ADE ,; PRODUCT CONTROL SECTION I"t 1 1805 SW 26 Strea-Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami.Florida 33175-2,174 BOARD AND CODE ADNIINISTRATION DIVISION T(786)315-25901:(78C),)315-2599 NOTICE OF ACCEPTANCE (MOA) ,„i.,,nid:,cic. ,�,rcconomy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. 'file documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority I-lavino.lurisdiction (AH.I). This NOA shall not be valid after the expiration date Stated below. The Miami!Dade County product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product;or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the ;AI-IJ niay immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves tine right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida 136ilding Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIP"CION: ('�AF�Cinnb'ca 1i�HD Timberline Natutral Shadow`",and Timberline American Harvest"' Shingles LABELING: Each unit shall bear it permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has beenfiled grid ihere'has beci no change in the applicable building code negatively affecting the performance ofthis produce. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product c•process. Misuse of this NOA as an endorsement orally product, for sales,advertising or any other purposes shall automatically terminate this NOAI Failure to comply with any section of this NOA shall be cause for termination and rennoval of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida,' and followed by the expiration date nnay be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages I through 6. The submitted documentation was reviewed by Juan E.Collao, R.A. NOA No.: 14-1022.20 MIAMI-DADE COUNTY Expiration Date: 02/21/17 Approval'Date: 02/05/15 Page I of 6 • 1 �i j r, ROOFING ASSEMBLE'APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood I SCOPE . This approves GAF Timberline HD's',Timberline Natural Shadow`',and Timberline A!nerican Harvest`c' Shingles as manufactured by GAF as described in Section 2 of this Notice of Aceeptance. PRODUCT DESCRIPTION Product Dimensions Test Produet Description Specifications GAFTianberlfjik Hl 13 /.I x 39 /s TAS 110 Fiberglass reinforced heavy weight asphalt r urrr factzu i�rg roof shingle, with`",a laminate profile Locations#l,2,3,4,5,6,7 GAF Timberline Natural 13 I/.r•,x 39;/�' TAS 1 10 Fiberglass reinforIced heavy weight asphalt Shadow'"' roof shingle,witfiJa laminate profile 1'plcrrzzffcrcturing Ei ' Locations#1,2,3,4,5,6,7 GAF Timberline American 13 r/,r'x 39'/K' TAS 110 Fiberglass reinforced heavy weight asphalt Harvest'"' roof shingle,witNa laminate profile ,Manz fcrctzu•in�J " Locations#2,4,5,6 MANUFACTURING LOCATION 1. Tampa, Fl_, i 2. Michigan City, rN " 3. Baltimore, MD ;1 ; 4. Myerstown, PA 5. Ennis,'rx 6. Tuscaloosa,AL 7. Dallas,TX l is � NOA No.: 14-1022.20 MIAMI•DADE COUNTY r' .•••• ; Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 2 of 6 C' j I' i, d I I I,I ,i. I, I EVIDENCr SUBMTfTED Test Ageney Test Identifier Test Name/Report Bate Underwriters Laboratories,Inc. ASTM D3462 I I CA48924 10/24/11 Underwriters Laboratories, Inc ASTM D3462 I OCA21994 04/22/11 Underwriters Laboratories, Inc ASTM D3462 I OCA287I7 07/26/1 I Underwriters Laboratories, Inc. ASTM D3462 OkA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NK05F59 08/09/06 PRI Asphalt Technologies, Inc. ASTM D3462 GA1-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 6NK418'09 08/1 1/02 Underwriters Laboratories, Inc. ASTM D3462 0'3NK264,44 10/17/03 Center for Applied Engineering ASTM D3462 2579891 05/13/97 Underwriters Laboratories, Inc. TAS 107 0INK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 016NK051'59 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/0.4 Underwriters Laboratories, Inc. TAS 107 05CA42Z40 1 1/1 1/05 Underwriters Laboratories, Inc. TAS 107 02NK4181 1 1 111 1/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories, Inc. TAS 107 64CA 13850 08/30/04 Center I-or Applied Engineering TAS 100 257989 04/01/97 PRI AsphaltTechnolo,ies, Inc. 'rAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, Inc. TAS 100 GAF-098=02-01 11/08/05 PRI Asphalt'fechnologics, Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt`I'echnologics, Inc. TAS 100 GAP-I 16-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 EL 1 K-0 83-02-0 1 10/16/02 ELK-084-02-01 10/15/02 ELIC-085;02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 EILK-088.02-01 10/16/02 EI%K-1072,02-01 10/09/03 ELK- 10/09/03 ELK-109-02-01 10/09/03 I ,a L,iMITATIONS I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the 'Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. i� I J, NOA No.: 14-1022.20 MIAMI-DADE COUNTYM Expiration Date: 02/21/17 Approval Date: 02/05/15 iI Page 3 of 6 I'I' I, •i INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Scandalid RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W, attached'. 5. Nailing shall be in compliance with Detail 'B',attached. LABELING Shingles shall bear the imprint or identifiable marking of the manUfacturer's' name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. NIAM I•DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable, code in order to properly evaluate the installation of this system. NOA No.: 14-1022.20 MIAMI•DAMCOUNTY Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 4 of is u. DETAIL A COURSE LAYOUT f , DECK f'I I ; ji FULL 5th I 17"OFF 4th ,I If, 11" OFF 3rd E �'I 6" OFF 2la'd i FULL 1st MtAM4DADE COUNTY NOA No.: 14-1022.20 .� j, Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 5 of G 'f, , I ii I" I DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN I' 39-3/811 �— 14-1/2"-17-1/2" 14-1/2"-17-1/2!' ;-I (36B-445(nm) (368-445mm) ',' ail guide line 6-1/2"-9-1/2" 6-1/2" 9-1/2' � 5-314°-6=1/4" ('f (165-241mm) (165-241—) 13-1/4 (146mm-159mm) (337mm) from bottom ofshinrgle (19-64 I I Se lf seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. i'. These shingles MUST be nailed a nominal 6" (152mm)from bottom;of of shingle, above the cut outs, as shown. Nails must not beexposed., I� s END OF TRIS ACCEPTANCE , i, el P. 1, I( I �I NOA No.: 14-1022.20 =MIAMI-DMADECOUNTY Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 6 of i' ;l'