FL# F1.10674-1112
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC
and/or the Commission if necessary.
Comments
Archived Eli
Product Manufacturer Owens Coming
Address/Phone/Emali One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeter@owenscoming,com
Authorized Signature Greg Keeler
greg.keeier@owenscoming.00m
Technical Representative Met Sancrant
,Address/Phone/Email i Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mei.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Emali
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
19 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M.Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R12 COI 201fi 01 COI Nieminen odf
Referenced Standard and Year(of Standard) Standard XC
ASTM D3161 2009
ASTM D3462 - 2009 .
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Cade
h4://www.floridabuilding.org/pr/px app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%... 11/21/2016
Page 2 of'2
Product Approval Method Method 1 Option D
Date Submitted 04/18/2016
Date Validated 04/19/2016
Date Pending FBC Approval 04/20/2016
Date Approved 06/08/2016
Summary of Products
PL tt IModel,Number or Name Description
10674.1 Owens Coming Asphalt Roofing Shingles 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles
and Starters
Limits of Use Installation Instructions
Approved for use In HVHZ.-No FL10674 R12 It 2016 04 FINAL ER OC ASPHALT
Approved for use outside HVHZ.Yes SHINGLES F 16 - 12 d
Impact Resistant:N/A Verified By:Robert 3.M.Nleminen PE-59166
Design Pressure:N/A Created by independent Third Party:Yes
Other.Refer to ER,Section S. Evaluation Reports
FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT
SHINGLES 810674-R12.odf
Created by Independent Third Party:Yes
Contact Us:: 601 SI Ir_Stone Road.Tallahassee Fl.32399 Phone:850-487-1824
The State of Florida Is an AA(EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalts provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please
clickems.
Product Approval Accepts:
LtGFrrit-CWd
http://www.floridabuilding.org/pr/pr_app dtl.aspx?param—wGEVXQwtDgtBNbEY5V%... 11/21/2016
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9563
N STREET,UNIT#13
TRINITYI353 CHRISTIAN OXFORD,Cf 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R7
One Owens Corning Parkway FI.10674-1112
Toledo,OH 43659 Date of issuance:02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein. -
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
s'
Z
77
Robert J.M.Nieminen,P.E. The facsimile sealappearIng was authorized by Robert Nieminen,
P.E.onO4/18/2016.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983
document Signed,sealed hardooples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE: '
1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor Will acquire,a financial interest In any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
TPJNITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with.the following Standards. Compliance is subject to the installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Enti Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 DevonshireTm are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration`, TruDefinition' Duration, Duration' Premium Cool, TruDefinition Duration' Designer Color
Collection,TruDefinition'Oakridge, Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire Hip& Ridge Shingles, High Ridge,WeatherGuard HP Hip &Ridge Shingles, ProEdge Hip&Ridge
Shingles and DuraRidge"4 Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Pius and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
'Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7
CertFficote of Authorization 119303
FL10674R12
Revision 7:04/18/2016
Page 2 of 8
i
i
'\JTRINITY j ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasa=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Pius noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are
acceptable for use in all wind zones up to Vasd=150 mph(V,it=194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Cade and F.A.C.Rule 61G20-3.
6. INSTALLATION:
8_1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire shingles require minimum five(5)nails per shingle.
WeatherGuarde HP shingles require minimum six(6)nails per shingle.
➢ Devonshirelm shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Fe3turrdedaynbnt -Deck FdrunderMfnietrt DO& SdWhered
Self-adhered wasihaundnlsda
wex1harL0011+
undadarment
Drip
r
Ddpedp r,
r rI
r-rfrcand �a"
Y-3'from eeve
InsteC fust
udhes,ve 6i ctfnY adusiw
StarterStri SeHsrt6' Stripplua
posi6 akng Dave posttimed ekep coag
Starter strip shingle overhangs eaves and takes Yi—alt Shrgr plus overhangs$evq and rakes VC-3/4'
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
cerb'ficote of Authortration#9503
Fuo67a-R12
Revision 7:04/18/2016
Page 3 of 8
I
TRINITY ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
NOMWI Mansard or Atra para NonnN Mansard or Arra para
Wind Ana* High Wind dasvanra y OHndAn** High Wind dosvama y
Arra pan Wn**Wanton nonnarsa AWrnros lrrartra Aran Pam Wartoa noanaba An" rtatrtos fwrtss
E "Won
EirposlcNn
6.2.7 Minimum Nailing—Berkshirei°:
Sealant strip Snla t strip
Li tililit s0ifrdd LstFddsiBAsdOr
L
Yi „B Yr 8w 8w* 8 VY t
1" t• 1 t"J
s
r
Standard Fastening Pattern 6-Nail Fastening Pattern
Ssohnt strip
- G9wdaerlisc6r
`r s yr evr ss� `$vt
r
r -
2" A9phak rootiipoeieeni
Csaan2o delai84da adtYOa
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 437940.02.12-R7
Certificate ofAutharization#9503 FL10674•R32
Revision 7:04/18/2016
Page 4 of 8
TRINITY JE' RD
6.2.8 Minimum Nailing—DevonshireTM':
fes's.. .r
` . Naas
.......
6-Ww"Sm SeEletlt lDCetl011 } 4•
Evestdbn de 5.618 o!ca
pate Ubbdbn do! $
o„
Tan 1' Of alt Roof CemaM
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration" Premium Cool&TruDefinition®Duration®
Designer Color Collection:
Adan Featenlag_Pattem Mail F=Wftg Pafbrn
ygy,Va"w a GWOL%Vta mna.s.wn
t• tr j tr r tr +r
aur saws• ��' N.- . - e-tre
!I: w
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastanlnd for ebpm GtoaYw Than 21:12
tunrass�ataNnp�r,..wn
ar,types
t- tr is
b•ta•lair
Lf r
toQ 1•apab d tea Cw..eR
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-117
Centi/Irate o/Aothorizotion#'9503 F1.10674-1112
Revision 7:04/18/2016
Page 5 of 8
TRINITY IERD
6.2.1 Minimum Nailing—Tru Definition Oakridge°,Oakridge':
4 Nail Man 5 Nail Pattern
Espoo con 4 dawns EsVew cat 6 daws
1. T
S' T
SQlA"6�osuro spy 56t8"Exposura Mals.
Eipo;idbitddS614ddg Chios Expbslafb�tiliS6/QWdff 5strExpmn Cfavas 5¢i8"..Exposuw
8i�ostddndt56J8pidg Exposhforidi 66ISprig.
Standard Fastening Pattern 6-Nail Fastening Pattern
FasteMny for Siopn Gmd@r 7Rah21:12
M+o.lyylcM
r �r it
svr s am c
r
/ar t`ipobdA+p4M Roob+p C�A•nt
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard"HP:
■ '_ .s11M VMw
r' °��' �"` •.I`.jP•, Fitiuwri7tirtwrMi Nil lie
t3i�w lr lira.i,i}tlfs
Exterior Research and Design,LIC. Evaluation Report 037940.02.12-117
Certificate of Authorization#9503 FL30674-R12
Revision 7:04/18/2016,
Page 6 of 8
TRINITY I ERD
5_3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire*Hip and Ridge Shingles, High Ridge,WeatherGuardQ HP Hip and Ridge Shingles and
Prolidge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four
(4) nails per shingle. Installation of DuraRidger" Hip& Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand-sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—BerkshireO Hip&Ridge and High Ridge:
Fig.f 4, Fig.2
Median OreCton A isPYNew SNdevlm
rials^=-^--^----.—y A Nein "IS
4
Piece
4.
A
4
I 1 1 I
f
x
I
I
I
6.3.4 Minimum Nailing—WeatherGuard"HP Hip and Ridge:
Fig.C Hip&Ridge.Shingle fastening
Fig.A v 4 Top}nnw
OStW6 Yr6W A _
A
Nails-."—..--------j•4 4
A.
F MIND MIND
A
oryoauro
� exposure
17'
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7
Certificate ofAuthoriration#9503 FL10674-R12
Revision 7:04/18/2016
Page 7 of 8
"\PTR1N1TYj,ERC?
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prrwading Standard
Ifttatening
tarn
12.
6.3.6 Minimum Nailing—Duralkidge"Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
TOPIliew
Vele
come
i `
Alilt
4
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC*
Table 1507.2.7.1/R905,2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
Asrequired by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY AsSURANcE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7
Certificate ofAuthorization#9503 FL10674-Ri2
Revision 7,04/18/2016