HomeMy WebLinkAboutEngineering I f , I r i I PAUL WELCH INC. Mechanical Electrical Civil Engineering i 1984 S.W.Biltmore St. Suite#114 Port Saint Lucie, FL 34984 �. Phone(772) 785 - 9888 E-mail pwelchinc@aol.com February 22,2017 Re: Residential Re-Roof 660 Nettles Blvd. Jensen Beach, FL 34957 SCOPE OF WORK: Install new Metal Roof(Extreme Metal Fabricators,LLC "5-V Crimp",FL#1'7022.1)at above referenced address over new underlayment, and existing plywood sheathing. ;I DESIGN.CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT= 10'-0" A=3' MEAN ROOF HIEGHT=<20' ROOF ANGLE=4:12 SHAPE=PITCHED GABLE ADJUSTMENT FACTOR= 1.00 ;! RVIPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165MPH WIND VELOCITY V asd= 128 MPH EXPOSURE=D ENCLOSURE CLASS =ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE(PSF): ZONE 1 (Field)=-40.3 ZONE 2 (Perimeter/Ridge) _-68.0 ZONE 3 (Corners)_-99.8 Paul Welch Inc. I Paul Welch P.E. Reg.No.1 29945 February 22,2017 1 I:' 660 Nettles Blvd.Jensen Beach,FL 1 of 3 i 'F= 1 I METAL.ROOFING ATTACHMENT REQUIREMENTS: Metal roofing to be attached with corrosion resistant Hex-Head wood screws#10 x 11/Z" minimum with weather sealing washers (minimum 3/16"penetration through deck). Fasteners shallbeplaced through the panel ribs at 12"on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING= 16"O.C. ZONE 2 (Perimeter/Ridge): FASTENER SPACING= 16" O.C: ZONE 3 (Corners):FASTENER SPACING= 8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 &2: -93.5PSF/Zone 3: -101PSF Therefore O.K. UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines,FBC 1507.4.5.1,and FBC 15074.5.2. Underlayment shall be Approved 30#Roofing Felt. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"OC. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL# 17022.1),manufacturer's specifications, and the Florida Building Code 2014. I,. d . I; `-Paul Welch Inc. Paul Welch P.E. Reg.No.29945 February 22,2017 660 Nettles Blvd.Jensen Beach,FL 2 of 3 AAKF- - `A 3===Z, I if: i i 1 i �! ifi 4 !I �! Ilk I Ill tt 1"K ROOF ZONE PLAN A=3' ZONE DESIGNATION(TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. Paul Welch Inc. Paul Welch P:E. Reg.No.29945 - February 22,2017 660 Nettles Blvd.Jensen Beach,FL - 3 60