HomeMy WebLinkAboutProduct Approval MIAM!•DADE MIAMI DADE COUNfY
PRODUCT CONTROL SECTION
DEPARTMENT.OI{'REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTR 'nON DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE .miamidade. ov/ecagpm
Sun-Tek Manufacturing,Inc. 11E''JIE!!'i:I FOR C
10303 General Drive
IE!lA1D Il} c
Orlando,FL 32824 D A.TI '
PLANS AND PERMIT MUST BE KEPT ON JOB
SCOPE: OR NO rSPECT1CN WILL BE MADE.
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control '
Section to be used in Miami Dade County and other areas where allowed by the Authority Raving Jurisdiction
(AIM.
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the A14J (in areas other than Miami Dade County)reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the. accepted manner, the manufacturer will incur the expense of such testing.and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RERreserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: ISFG Skylight Systeme
APPROVAL DOCUMENT: Drawing No. STI-00000298,titled"ISFG",sheet 1 &2 of 2,prepared by Sun-Tek
Manufacturing,Inc., dated August 07,2007,last revision#A dated May 04,2015,signed and sealed by James D.
Wells, Jr., P.E., on May 04, 2015, bearing the Miaini-Dade County Product Control Revision stamp with the
Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a-permanent label with the manufacturer's name or logo, city, state,
model/series and the following statement: "Miami-Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for.sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall
U done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official,
This NOA revises NOA#113-1028.05 and consists of this page 1, evidence submitted pages E-1,E-2, &E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.&
MIAMIDARE COU ��� NOA No.15-0513.10
NTY Expiration Date: 10/31/2018
oq f oT/ZoJS- Approval Date: 09/03/2015
Page 1
i
9
Sun-Tek Manufacturing,Inc. # , $ � 4l r?PY
NOTICE OF ACCEPTANCE:EVIDENCE SUBAHTTED
1., EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 407-0425.04
A. DRAWINGS
1. Drawing No. STI-00000298-SHTIISHT.2, titled `ISFG", sheet 1 & 2 of 2,prepared
by Sun-Tek .Manufacturing, Inc, dated 06104107 with last revision dated 08107107,
signed and sealed by Tames D. Wells,Jr.,P.E.
B. TESTS(submitted under NOA#02-0618.06)
1. Test Report on Large.Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of`Insulated Glass Skylight
with Polycarbonate Inner Liner" prepared by National Certified Testing
Laboratories, Report No. 210-2760-1, 2 & 3, dated 01122/02, signed and sealed by B.
Portnoy,P.E.
C. CALCULATIONS
1. Anchor Calculations for attachment.of skylight to curbing and curbing to decking,
dated 08113107, signed and sealed by James D. Wells, Jr., P.E.
D. MATERIAL CERTIFICATIONS(submitted under NOA#02-0618.06)
1. Test report on Bate of Burningper ASThiD635 of Geon 874.16 White 141
Exterior, 0:137 inch,prepared by Commercial Testing Company,Report No. 01-
11293, dated 1112910.1, signed by J.Jackson,
2. Test report on Self Ignition Temperature per ASTMD1929 of Geon 87416 White
141 Exterior,prepared by Commercial Testing Company, Report No. 01-11292,
dated 1.1129101, signed by J Jackson.
E. STATEMENTS(submitted under NOA#02-0618.06)
1. Code compliance letter issued by Product Technology Corporation. on 09127102,
signed and sealed by R J Quiroga P.E.
F. OTHER
1. NOA renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107,
James Feudner,
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.02
A. DRAWINGS
I. Drawing No. S7I-00000298-SRT1/8HT2, titled "ISFG", sheet 1 &2 of 2, prepared
by Sun-Tek Manufacturing, .Inc, dated August 07, 2007, last revision #A dated
October 14, 2011, signed and.sealed by James D. Wells, Jr., P.E.
eimy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No.15-0513.10
Expiration Date: 10131/2018
Approval Date: 09/031201.5
E-1
i
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED
B. TESTS
1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified
Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness,
signed by Mark Bennett, Manager of Testing Services.
C. 'CALCULATIONS
1. None.
D. QUALITY ASSURANCE
-1. By Miami-Dade County Department of Permitting, Environment, and Regulatory
Affairs(PERA).
E. MATERIAL CERTIFICATIONS
1. None.
3. EVIDENCE SUBAUTTED UNDER PREVIOUS APPROVAL#12-101115
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG"' sheet I & 2 of 2, prepared by Sun-Tek
Manufacturing Inc, dated August 07, 2007, last revision #A dated May 03, 2012,
signed and sealed by James D. Wells, Jr., P.E.
B. TESTS
1. .None.
C.- CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. OTHERS
1. A compliance letter,prepared by J&L 'Wells Consulting LLC, dated April 25, 2012,
certify compliance with FBC 2010 edition, sign&sealed by James D. Wells, Jr.,P.E.
2. Verification testing to be performed per letter from National Certified Testing
Laboratories, dated September 18, 2012, signed by Christopher Bennett.
Cl Helmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No.15-0513.10
Expiration Date: 10/31/2018
Approval Date: 09/03/2015
E-2 -
I
tri
PEI 11
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED
4, EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#13-1028.05
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG'; sheet 1 &2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, last revision #A dated August 15, 2013,
Signed and sealed by James D. Wells, Jr.,P.E, on February 07, 2014.
B. TESTS
1. Test Report on Large.Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass,Skylight
with Polycarbonate Inner Liner" prepared by National Certified Testing
Laboratories, Report No. 210-3915-01, dated 0812712013, signed and sealed by
Gerard Ferrara, P.E.
C. CALCULATIONS
1, Anchor Calculations for attachment of skylight Model ISFG to Decking, dated
1010312013, signed and sealed by James D. Wells, Jr.,P.E.
D. QUALITY ASSURANCE
1. By Miami Dade County Department of Regzdatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. Bill o f Material and Components Die Drawings,
5. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc„ dated August 07, 2007, last revision #A dated May 04, 2015,
signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
L By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
CMIelmy A.Makar,P.E:,M.S.
Product Control Section Supervisor
NO.A,No.15-0513.10
Expiration Date: 10/31/2018
Approval Date: 09/03/2015
E-3
PART NAME: ISFG SKYLIGHT ASSEMBLY FILE NAME: Z:1DWG1DWGIACAD 2000 DRAWINGS\DADE COUNTY ISFG STI-00000298
STI-215.DECO COVER 0.075 6063 T6 ALUM . 17/32" GLASS BITE
OUTBOARD DSB TEMPERED
SILICONE BEDDING (CONTINUOUS) 1/8°' INBOARD GLASS DSB TEMPERED
STI-6 GLASS GASKET EPDM
(CONTINUOUS) co INSULATED AIR SPACE
Un ARGON GAS FILLED
STI-401 WOOD LINER 1.16x0.935"
(CONTINUOUS) SWIGGLE SPACER(0. 5)
#8-32 PHILLIPS PAN HD SCREW AND HEX NUT
7 PER LONG SIDE 7 PER SHORT SIDE
.177 POLYCARBONATE SHEET
PALRAM PALSUN
LL a BUTYL 3 RINGS OF SEALANT STI-300 PVC LINER
0 BENEATH FLANGE (CONTINUOUS) GEON 87416 WHITE
w 0 AROUND PERIMETER OF FLANGE 141 EXTERIOR
U (CONTINUOUS) AND ON TOP OF EACH
z Q FLANGE SCREW AIR SPACE OR
DADE COUNTY APPROVED
SHINGLES EXPANDED POLYSTYRENE INSULATION
(SEE NOTE 1)
ROOF DECK mins" thick
DESIGN PRESSURE RATING+/- 8pvP_SF
LARGE MISSILE IMPACT RESISTANCE'
Engineer of Record
James D. Wells, Jr.,P,E. ,:�
Professional Engineer No. 53616 NOTE:
* (1)ALL ROOFING DETAILS SHALL COMPLY WITH
nuAnTt'n 4C nC -YUC CI P 01MA DI Ili nit%lr ( nnC 0)01A orli+ir
PART NAME: ISFG SKYLIGHT PLAN VIEW FILENAME: Z:\DWG\DWG\ACAD2000DRAVMNGSXDAIDE COUNTY ISFG STI-00000298
54.5 STI-214 DECO R
tip to tip .O
4.000 5.8125 4.000 OSILICONE BEE
5.8125 O
5.8 25 5. 125 STI-6 GLA:
STI-41
STI-205 CMG FRAME 0,06(
5.8125 WELDED CORNER
08-32 X I"PHILLIPS
I Q f I O AND HEX N
FASTENERS SKYLIGHT SAND 80TT
TO DECK#8 X V' (9) PER SIDE
~
STI-20-
4
u- a
OJ
0 ISFG 4949 I I w 0 3 R11
BENEAI
_� AROUN
SYME RICAL o M (CONTINUO
411
r.
O SH:
(SE
C
0
FASTENERS SUB-FRAME TO FRAME ~ #a x SCREW(s} PER
I I I min.protr
O
l ti} ROOF DE
- - 'MININUM LIP
® =�glROOF SURFA(
r. 0 y,_. t
DESIGN PRESSURE RATING+I-80 PSF.
LARGE MISSILE IMPACT RESISTANCE N Engineer of Reco d�,.
NOTE: .fames D. Wells, Jr.,F�`E.
* (1)ALL ROOFING DETAILS SHALL COMPLY WITH Professional Engineer No. 53616
nLIADTCD 4A nir-rWC: 1:1 f1C?ir)A Ml ill i)lAl('- ( 0r)1C ')01(A orlitinn PP-MUCrRRVISGD
i
d<
n t
s
f "
S ;u ,-mmeir
LOSS n Winter
O
A T f.L" 1� �Iod0
p �'k
g�«
o1
CL0
Mu
a i,
� C �Q�C '�O
Gloss Skylights from Sun-Tek
• ��P x
LoE3-340 over Clear Tempered (std)
Laminated & Impact Available
maser-allows in the least
amount of heat to your home
® In Winter- keeps the most heat in
your home of any availble glass on ' .!
the market j
Uhak
SKYL/IjtHTS
Sun-Tek Manufacturing, Inc o 10303 General Drive a Orlando, Fl.32824
Ph: 800-334-5854 - Fx: 800-331-6607 s www.Sun-Tek.com e CustomerService@Sun-Tek.com
Understanding Thermal Properties
On Glass Performance
Solar Heat Gain Coefficient(SHGC)
I �
measures how much heat from the sun is blocked.
The lower the SHGC,the more the skylight is
blocking heat entering the living space.
U-Factor • 0>SHGC>1
measures how well your 6 • lower is better
•
skylight prevents heat from
•
escaping a Living P space.
4 -
d ( }
• 0.15>Ufactor>1.204�r
tower is better
Visible Transmittance(VT) , Ultraviolet Light(UV)
measures how much light comes considered the energy that accounts
through the skylight. for the majority of fading of materials
• 0>VT>100% and furnishings.
• Personal Preference ,'` • 0>UV>1
• tower is better
Insulated Glass Thermal Properties Comparison
Glass U-Factor SHGC VT.` UV
Single Pane, Clear 1.04 .86 90% .73
_.,_,._ . _.�.._.._......__. __.._ _._.r _ r, ------. — _
;Ted/ClrTemp.w/Argon 48 63 61% '
int32
__._.._..__. ._._.___........_............o_-_-.__.._�_.__ __..
Low-a/ClrTemp w/Argon .30 .72 76% .50
LoE2 240/ClrTem w/Ar,on 26 25. 39% 16
LoE3 366/ClrTempw/Argon .24 .27 65% .05
1-oE3 340/MrTemp w/Argon . 24 .18 39%"' .02
Condensation
' Condensation in your home is caused by excess humidity or invisible watervapor in
the air.The warm air in your home can hold large amounts of this water vapor(much
more than cold air).When the moisture-laden warm air comes in contact with a cool
surface, the vapor condenses to form actual water droplets.This is the cause of the
condensation you see on the inside of your skylights or windows.The lower the
U-Factor&SHGC thermal numbers, the better result reducing condensation.
.......................................................................................................................................................................................................
" c ocrey
q � �cur -r E~ ,... 1-800-334-5854
i