Loading...
HomeMy WebLinkAboutProduct Approval MIAM!•DADE MIAMI DADE COUNfY PRODUCT CONTROL SECTION DEPARTMENT.OI{'REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTR 'nON DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE .miamidade. ov/ecagpm Sun-Tek Manufacturing,Inc. 11E''JIE!!'i:I FOR C 10303 General Drive IE!lA1D Il} c Orlando,FL 32824 D A.TI ' PLANS AND PERMIT MUST BE KEPT ON JOB SCOPE: OR NO rSPECT1CN WILL BE MADE. This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control ' Section to be used in Miami Dade County and other areas where allowed by the Authority Raving Jurisdiction (AIM. This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the A14J (in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the. accepted manner, the manufacturer will incur the expense of such testing.and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RERreserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ISFG Skylight Systeme APPROVAL DOCUMENT: Drawing No. STI-00000298,titled"ISFG",sheet 1 &2 of 2,prepared by Sun-Tek Manufacturing,Inc., dated August 07,2007,last revision#A dated May 04,2015,signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015, bearing the Miaini-Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a-permanent label with the manufacturer's name or logo, city, state, model/series and the following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for.sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall U done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This NOA revises NOA#113-1028.05 and consists of this page 1, evidence submitted pages E-1,E-2, &E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.& MIAMIDARE COU ��� NOA No.15-0513.10 NTY Expiration Date: 10/31/2018 oq f oT/ZoJS- Approval Date: 09/03/2015 Page 1 i 9 Sun-Tek Manufacturing,Inc. # , $ � 4l r?PY NOTICE OF ACCEPTANCE:EVIDENCE SUBAHTTED 1., EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 407-0425.04 A. DRAWINGS 1. Drawing No. STI-00000298-SHTIISHT.2, titled `ISFG", sheet 1 & 2 of 2,prepared by Sun-Tek .Manufacturing, Inc, dated 06104107 with last revision dated 08107107, signed and sealed by Tames D. Wells,Jr.,P.E. B. TESTS(submitted under NOA#02-0618.06) 1. Test Report on Large.Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of`Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-2760-1, 2 & 3, dated 01122/02, signed and sealed by B. Portnoy,P.E. C. CALCULATIONS 1. Anchor Calculations for attachment.of skylight to curbing and curbing to decking, dated 08113107, signed and sealed by James D. Wells, Jr., P.E. D. MATERIAL CERTIFICATIONS(submitted under NOA#02-0618.06) 1. Test report on Bate of Burningper ASThiD635 of Geon 874.16 White 141 Exterior, 0:137 inch,prepared by Commercial Testing Company,Report No. 01- 11293, dated 1112910.1, signed by J.Jackson, 2. Test report on Self Ignition Temperature per ASTMD1929 of Geon 87416 White 141 Exterior,prepared by Commercial Testing Company, Report No. 01-11292, dated 1.1129101, signed by J Jackson. E. STATEMENTS(submitted under NOA#02-0618.06) 1. Code compliance letter issued by Product Technology Corporation. on 09127102, signed and sealed by R J Quiroga P.E. F. OTHER 1. NOA renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107, James Feudner, 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.02 A. DRAWINGS I. Drawing No. S7I-00000298-SRT1/8HT2, titled "ISFG", sheet 1 &2 of 2, prepared by Sun-Tek Manufacturing, .Inc, dated August 07, 2007, last revision #A dated October 14, 2011, signed and.sealed by James D. Wells, Jr., P.E. eimy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No.15-0513.10 Expiration Date: 10131/2018 Approval Date: 09/031201.5 E-1 i Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED B. TESTS 1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness, signed by Mark Bennett, Manager of Testing Services. C. 'CALCULATIONS 1. None. D. QUALITY ASSURANCE -1. By Miami-Dade County Department of Permitting, Environment, and Regulatory Affairs(PERA). E. MATERIAL CERTIFICATIONS 1. None. 3. EVIDENCE SUBAUTTED UNDER PREVIOUS APPROVAL#12-101115 A. DRAWINGS 1. Drawing No. STI-00000298, titled "ISFG"' sheet I & 2 of 2, prepared by Sun-Tek Manufacturing Inc, dated August 07, 2007, last revision #A dated May 03, 2012, signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. .None. C.- CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. OTHERS 1. A compliance letter,prepared by J&L 'Wells Consulting LLC, dated April 25, 2012, certify compliance with FBC 2010 edition, sign&sealed by James D. Wells, Jr.,P.E. 2. Verification testing to be performed per letter from National Certified Testing Laboratories, dated September 18, 2012, signed by Christopher Bennett. Cl Helmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No.15-0513.10 Expiration Date: 10/31/2018 Approval Date: 09/03/2015 E-2 - I tri PEI 11 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED 4, EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#13-1028.05 A. DRAWINGS 1. Drawing No. STI-00000298, titled "ISFG'; sheet 1 &2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, last revision #A dated August 15, 2013, Signed and sealed by James D. Wells, Jr.,P.E, on February 07, 2014. B. TESTS 1. Test Report on Large.Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass,Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-3915-01, dated 0812712013, signed and sealed by Gerard Ferrara, P.E. C. CALCULATIONS 1, Anchor Calculations for attachment of skylight Model ISFG to Decking, dated 1010312013, signed and sealed by James D. Wells, Jr.,P.E. D. QUALITY ASSURANCE 1. By Miami Dade County Department of Regzdatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. Bill o f Material and Components Die Drawings, 5. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc„ dated August 07, 2007, last revision #A dated May 04, 2015, signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE L By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. CMIelmy A.Makar,P.E:,M.S. Product Control Section Supervisor NO.A,No.15-0513.10 Expiration Date: 10/31/2018 Approval Date: 09/03/2015 E-3 PART NAME: ISFG SKYLIGHT ASSEMBLY FILE NAME: Z:1DWG1DWGIACAD 2000 DRAWINGS\DADE COUNTY ISFG STI-00000298 STI-215.DECO COVER 0.075 6063 T6 ALUM . 17/32" GLASS BITE OUTBOARD DSB TEMPERED SILICONE BEDDING (CONTINUOUS) 1/8°' INBOARD GLASS DSB TEMPERED STI-6 GLASS GASKET EPDM (CONTINUOUS) co INSULATED AIR SPACE Un ARGON GAS FILLED STI-401 WOOD LINER 1.16x0.935" (CONTINUOUS) SWIGGLE SPACER(0. 5) #8-32 PHILLIPS PAN HD SCREW AND HEX NUT 7 PER LONG SIDE 7 PER SHORT SIDE .177 POLYCARBONATE SHEET PALRAM PALSUN LL a BUTYL 3 RINGS OF SEALANT STI-300 PVC LINER 0 BENEATH FLANGE (CONTINUOUS) GEON 87416 WHITE w 0 AROUND PERIMETER OF FLANGE 141 EXTERIOR U (CONTINUOUS) AND ON TOP OF EACH z Q FLANGE SCREW AIR SPACE OR DADE COUNTY APPROVED SHINGLES EXPANDED POLYSTYRENE INSULATION (SEE NOTE 1) ROOF DECK mins" thick DESIGN PRESSURE RATING+/- 8pvP_SF LARGE MISSILE IMPACT RESISTANCE' Engineer of Record James D. Wells, Jr.,P,E. ,:� Professional Engineer No. 53616 NOTE: * (1)ALL ROOFING DETAILS SHALL COMPLY WITH nuAnTt'n 4C nC -YUC CI P 01MA DI Ili nit%lr ( nnC 0)01A orli+ir PART NAME: ISFG SKYLIGHT PLAN VIEW FILENAME: Z:\DWG\DWG\ACAD2000DRAVMNGSXDAIDE COUNTY ISFG STI-00000298 54.5 STI-214 DECO R tip to tip .O 4.000 5.8125 4.000 OSILICONE BEE 5.8125 O 5.8 25 5. 125 STI-6 GLA: STI-41 STI-205 CMG FRAME 0,06( 5.8125 WELDED CORNER 08-32 X I"PHILLIPS I Q f I O AND HEX N FASTENERS SKYLIGHT SAND 80TT TO DECK#8 X V' (9) PER SIDE ~ STI-20- 4 u- a OJ 0 ISFG 4949 I I w 0 3 R11 BENEAI _� AROUN SYME RICAL o M (CONTINUO 411 r. O SH: (SE C 0 FASTENERS SUB-FRAME TO FRAME ~ #a x SCREW(s} PER I I I min.protr O l ti} ROOF DE - - 'MININUM LIP ® =�glROOF SURFA( r. 0 y,_. t DESIGN PRESSURE RATING+I-80 PSF. LARGE MISSILE IMPACT RESISTANCE N Engineer of Reco d�,. NOTE: .fames D. Wells, Jr.,F�`E. * (1)ALL ROOFING DETAILS SHALL COMPLY WITH Professional Engineer No. 53616 nLIADTCD 4A nir-rWC: 1:1 f1C?ir)A Ml ill i)lAl('- ( 0r)1C ')01(A orlitinn PP-MUCrRRVISGD i d< n t s f " S ;u ,-mmeir LOSS n Winter O A T f.L" 1� �Iod0 p­ �'k g�« o1 CL0 Mu a i, � C �Q�C '�O Gloss Skylights from Sun-Tek • ��P x LoE3-340 over Clear Tempered (std) Laminated & Impact Available maser-allows in the least amount of heat to your home ® In Winter- keeps the most heat in your home of any availble glass on ' .! the market j Uhak SKYL/IjtHTS Sun-Tek Manufacturing, Inc o 10303 General Drive a Orlando, Fl.32824 Ph: 800-334-5854 - Fx: 800-331-6607 s www.Sun-Tek.com e CustomerService@Sun-Tek.com Understanding Thermal Properties On Glass Performance Solar Heat Gain Coefficient(SHGC) I � measures how much heat from the sun is blocked. The lower the SHGC,the more the skylight is blocking heat entering the living space. U-Factor • 0>SHGC>1 measures how well your 6 • lower is better • skylight prevents heat from • escaping a Living P space. 4 - d ( } • 0.15>Ufactor>1.204�r tower is better Visible Transmittance(VT) , Ultraviolet Light(UV) measures how much light comes considered the energy that accounts through the skylight. for the majority of fading of materials • 0>VT>100% and furnishings. • Personal Preference ,'` • 0>UV>1 • tower is better Insulated Glass Thermal Properties Comparison Glass U-Factor SHGC VT.` UV Single Pane, Clear 1.04 .86 90% .73 _.,_,._ . _.�.._.._......__. __.._ _._.r _ r, ------. — _ ;Ted/ClrTemp.w/Argon 48 63 61% ' int32 __._.._..__. ._._.___........_............o_-_-.__.._�_.__ __.. Low-a/ClrTemp w/Argon .30 .72 76% .50 LoE2 240/ClrTem w/Ar,on 26 25. 39% 16 LoE3 366/ClrTempw/Argon .24 .27 65% .05 1-oE3 340/MrTemp w/Argon . 24 .18 39%"' .02 Condensation ' Condensation in your home is caused by excess humidity or invisible watervapor in the air.The warm air in your home can hold large amounts of this water vapor(much more than cold air).When the moisture-laden warm air comes in contact with a cool surface, the vapor condenses to form actual water droplets.This is the cause of the condensation you see on the inside of your skylights or windows.The lower the U-Factor&SHGC thermal numbers, the better result reducing condensation. ....................................................................................................................................................................................................... " c ocrey q � �cur -r E~ ,... 1-800-334-5854 i