HomeMy WebLinkAboutProduct Approval (4) Florida Building Code Onlibe http://www.floridabuilding.org/pr/pi _appjtl.aspx'lparani=='A,(iEVX...
BCIS Home ± Login user RegistratlDn
1 Hot Topics Submit Surcharge Stats&Facts
Publications F8C Staff BCIS Site Ma
�usnes��:� :: a:
Product Approval
Professional USER:P u b R c U s e r
> searih>Appftatjo�_�. >Appirkation Detail
FL# FL2569-RII
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@so.prema.ca
Technical Representative Marc-Etienne Mathieu
Address/phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathleu@soprema,ca
Quality Assurance,Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect o
Florida Professional Engineer.
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed -Robert J. M. Nieminen
the Evaluation Report -
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich, RE
of 1/5/2016 3:08 PM
-loridaBuiiding Code Online http://www.floridabuilding.org/pr/pr app_dtl.aspx?paranl=wGEVX...
Validation Checklist-Hardcopy Received
Certificate of Independence
'7L2569 R11 COI 20115 01 CrUl Nti
Referenced Standard and Year(of Standard) Standard
ASTM D1970
ASTM D6163
ASTM D6164
FM 4474
FRSA/TRI April 2012(04-12)
TAS 103
TAS 110
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summary of Products
FL# Model,Number or Description
(Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use installation instructions
Approved for use in HVHZ: No R21 II 2015 10 FINAI- ER SOPREMA CA UNDERLAW
Approved for use outside. P11.pff
HVHZ:Yes Verified By: Robert Nieminen, P.E. PE-59166
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-90 Evaluation Reports
Othert 1.) Refer to ER Section 5 for EL2569 R11 AE 201 1 FINAL ER SOPREMA r-A UNGE�I.AY
Limits of Use. 2.)The design pressure R11-od
noted herein pertains to underlayment Created by independent Third Party: Yes
systems used,beneath adhesive-set tile'
systems. Refer to ER Section 5.6.4 for
details.
'Back rrNext;
re
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487=1824
The State of Florida is an AA/EEO employer. State of Florida.::privacy Statement:: c-es ibilU stat men
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records req
of 3 1%5/2016 3:08 PM
Floixda Building Code Online http:Hwww.floridabuilding.org/pr/pr_app_dtl.aspx`lparam=wGEVX..:
electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please cdntact 850.487.
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter'455,F.S.must proVide the Department wi
they have one.The emalls provided may be used for official communication with the licensee.Howeveremall addresses are public record.If
supply a personal address;please provide the Department With an email address which can be made available to the public.To determine if yo
Chapter 455,F.S.,please ctbkbem,
Product Approval Aoeepts:
0 MOM
of 3 1/5/2016 3:08 PM
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certfficate of AuthorizaUon#9503
353 CHRISTIAN STREET,UNIT#13
?MD OXFORD,CT 06478
PHONE:(203)'262-9245
FAX:(203)262-9243
EVALUATION REPORT
Soprema,Inc. Evaluation Report S18010.06.09-R9
154Orue Haggerty* r^2%9-111^
�
Drummondville,Om6bec.12CSPB Date of issuance.06/15/2009
.Canada Revision 9:t0/12/2015
SoOpc|
This Evaluation Report.is issued under Rule 61G20`3 and the applicable mu|nx and regulations gmxennin8 theose of
construction materials in the State of Florida.The documentation submitted has been reviewed by-Robert Nierninen,
P.E. for use of the product under the Florida Building Code and Florida 8u||6in8 Code, Residential Volume. The
products described herein have been evaluated fnrconop||ance with the Sm Edition (2014) Florida Building Code
secL|onsnoted herein.
DESCRIPTION: Sopnemnm RmmfQndmnlaymenty
LABELING: Labeling uhoU be in accordance with the requirements the Accredited Quality Assurance Agency noted
' herein. �
CONTINUED COMPLIANCE. This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
bP.E.
this Evaluation' Report �by the named client constitutes agreement to notify Robert miem/nen^ p' ' /fthe product
changes orthe referenced Quality Assurance documentation changes. Trinity IERDrequires acomplete review ofthis
Evaluation Report relative tnupdated Code requirements with each Code Cycle.
�
ADVERTISEMENT: The Evaluation Report number preceded bythe words 'Trinity|ERD Evaluated" may bedisplayed in
od.vmtising|itenature. |fany portion ofthe Evaluation Report isdisplayed,thpn|tshoUbedonoin'ityentirety.
INSPECTJPN:Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at theJob site.at the request of the Building.Official.
This Evaluation Report consists ofpages Ithrough 7'
Prepared by:
'
----
.�
�
u����/ =u���x��
�m�m�l8�,��nmX�em,��E' '~�����1�"~~.This�����~°^"""w"�=�����a
Florida Registration No.a9z56Florida DCA Ams1soy *=ment�Signed.sealed h.mm'*°have**"transmitted mthe
p=^"=^w=°/^umw*mm,an^*m"named client '
cERT/"ICAnuwurINvs,Ewv,mcs:
1. Trinity|ERDdoes not have, not does itintend toacquin,orwill itacquire, afinancial interest in any company manufacturing,o,
distributing products It evaluates.
2. Trinityl ERD is not owned,operated oricontrolled by any company manufacturing or distributing products it evaluates.
a. Robert w|eminen,p.s.does not have nor will acquire,a financial interest many company manufacturing ordistributing products for
which theexa|uadnnreports are being issued.
4. Robert wleminen,pc.does not have,nor will acquire,afinancial interest inany other entity involved inVie approval process oftile
pmcluct
s. This Is a building code evaluatlon. Neither Trinityl ERD nor Robert Nieminen, P.E.are, In any way,theDemignerpfRecord for any
project on Which this Evaluation Report,'or previojjs versions thereof,is/was used for permitting or.de�ign guidance unless retained
specifically for that purpose.
�
�
'
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is-subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3:1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009
1507.2.9.2,1507.4.5.1,
1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005.
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS'110 Accelerated Weathering TAS 110 2000
1507.3..3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3, REFERENCES:
Entity Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05=2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-Ri 04/1B/2007
ERD(TST6049) TAS 103/TAS 110 S7120.1.1.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970 S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EV.L2396) 2012,2009 and 2006 ISC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/46/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R9
Certificate of Authorization it9503 FL2569-R11
--- Revision 9:10/12/2015
Page 2 of 7
,
.
\ �
/���t
Q ��8 �� � � �����^
4.4 Loatubnnd Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, S85 modified
`
bitumen roof undodayment
45 Lautobond Pro HT-N is a solf-adhering, woven polyethylene surfaced, SBS modified bitumen roof
uudedaymentavailable intwo widths;36and 4Sinch.
4.6 Los�tubond Pro HT-S is o self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof unde,laymant.
4.7 Lastobond195 ix u *e(f-adhering, glass-mat reinforced, sand-surfaced, 3B3 modified bitumen roof
undedayment
4.8 Lmstobond is a self-adhering, glass-mat reinforced, sand-surfaced, SBI modified bitumen roof
undodaymont'
4.9 Uotobnnd Eco is � self-adhering, glass-mat reinforced, sand-surfaced, S85 modified bitumen roof
' undedayment.
4.10 La$obond8mooth Seal HTis o self-adhering, glass-mat reinforced, fi|m*urfaced^ SBS modified bitumen
roofunder|aymant. '
4.11 RES|STO iB1236 is o self-adhering, 8|oxu-nat reinforced, sand-surfaced 88S modified bitumen roof
undor|aymwnt,with a3$-|nchsheet width.
4.12 PrImeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat reinforced,sand-surfaced,SBS-
modifiedbitumenronfundpr|myment'w)thm38-inohsheetwidth.
4.13 RE5/STO LB1244 Is a self-adhering, glass-mat reinforced, sand-surfaced, 38S modified bitumen roof
undodayment,with a44'inchsheet width.
4.14 Cohphene FR GR is o self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof
undedaymont.
4'15 Uni|ay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
under!ayment.
S. Li,moxnjomo:
5.1 Thisis a bunding coda evaluation. NeithmrThnityl.ERD nor Robert mieminen, P.E. are, in any way\ the
Designer ofRecord for any project onwhich this Evaluation Report, orprevious versions thereof, imkmau
usectfor permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report i,not for use inthe HVHZ.
5.3 Fire C|aso��tinn is not pa�ufthis repur� o
refer Materials 0 �.
current Hoofn8recryfnrfire
ratings-of this product.
` 5.4 Soprema Roof Undierlayments may be*used with any prepared roof cover where the product is specifically
referenced within F8Capprova| documents. If not listed,o request may be made tothe AH] for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable.roof covers applied atop the ondedpymentoare follows:
TOLE 1: ROOF COVER OPTIONS
Asphalt Nall-Or! Foam-On Wood Shakes&
Underlayrnent Shingles Tile Tile Metal Shingles Slate
Lastobond TU HT Yes Yes Yes - Yes Yes Yes
See 5.5.1
Yes No No No Yes Yes'
RESISTO SA SMOOTH PLY 40
Lastobond5h1e1dHT/ProHT-S �es No No Yes Yes Yes
�—Yes No No No Yes Yes
'
Exterior mesearchand Design,I.I.C. Evaluation Report u1uv1no*�9-ny
carwm=te"fAu"hoxzedo"x9503 rm56*1112
`
Revision 9:10/12/2015
Page x*,r
-.,."TRINITY:z RD .
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Foam-On Metal Wood Shakes& Slate
Shingles Tile Tile Shingles
Lastobond ECO /RESISTO
LB1236,Grip-Rite Eave&Valley Yes. No No No Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Yes
Colphene FR GR Yes Yes See 55.1 No Yes Yes
Yes Yes
Unilay(e) Yes Batten Only See 55.1 No No No
5.5.1 "Foam-On tile" is limited to.use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond"'Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195,. Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
v Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
9 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond,. Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to.:
> Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For Installations
under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
Exterior Research and Design,I.I.C. Evaluation Report 51$010.06.09-R9
Certificate of Authoritatloa119503 FL2569-RII
Revision 9:10/12/2015
Page 4 of7
RD
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB124.4,Lastobond Smooth Seal HT or Colphene FR GR applied to:
➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12).
.5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on the systems;where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-ori tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FOC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6:4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocoi Stick or Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2. Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol60oc
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and.6-inch o.c.in three,equally
spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90:0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with 5oprafix Polymer Batten Bar (PB8) or Soprafix
Metal Batten Bar(MBB) with Soprema#15-EL fasteners spaced 6-inch o.c,within the 5-
inch wide, self-adhering side laps. End laps are 6-inch wide and sealed using either
heat-welding or hot-air welding techniques.
5.7 Exposure Limitations:
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO 1-61236, Grip-Rite Eave & i
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-day5after
installation.
Exterior Research and Design,LLC. Evaluation Report 518010M.U9-119
CertWeate of,4uthorization#9303 FL25659-1111
..Revision 9:10/12/2015.
Page 5 of 7
TRIN ERD
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or
Elastocol'600c(if applicable).
6.3 Lastobond TU HT Lastobond Shield Lastobond Pro HT-N.RESISTO SA SMOOTH PLY 40,Lastobond Shield
HT Lastobond Pro HT-S,Lastobond Lastobond 195 Lastobond Eco, Lastobond Smooth Seal HT:RESISTO
LB1236 Grip-Rite Eave&Valley Protector RESISTO L81244 or Colphene FR GR:
63.1 Shall be installed In compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final
roof cover is not slated for'lnstallation within.24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release.film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight..Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding.or hot air welding techniques.
When Installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction.. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR G13-only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1•herein, using the
instructions noted above as a guideline.
For foam-on tile applications, reference is made to Section•5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
4 Unila e :
6.4.1 Non-Tile Applications or Nail-On.Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if applicable).
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope,
mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-
nails spaced 36-inch o_c. Apply the second course in a water-shedding manner with self-adhering side-
laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight
application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-119
Certificate ofAuthorizotlon 89503 171.2569-11ii
Revision 8.:10/12/2015
Page 6 of 7
JEAD
TRINII
Tile(if applicable)shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment:
6.4.2 Foam-On Tile Applications:
Reference is made.to FRSA/TRI April 2012 (04-12) Installation Manual, Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting. at the eave with the selvedge-edge upslope,
mechanically,attach the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar(PBB)or
Sopraflx Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second
course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 2:-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using either.heat-welding or hot-air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to .the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building official or Authority Having Jurisdiction in order to properly evaluate the.installation of
this.product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under- Rule 61G20-3 QA
requirements'.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation.Report 518010.06.09-119
Certifkate of AuMorkation.#9503 FL2569-R21
Revision 9:10/12/2015
Page Tof 7