Loading...
HomeMy WebLinkAboutEngineering PAUL WELCH INC. Mechanical * Electrical * Civil Engineering RECEIVED 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 FEB 2 7 2012 Phone (772) 785 - 9888 Email pwelchinc@aol.com r LuciePERMITTINGunty, St. Lucie County, FL December 1, 2016 "OwILE COPY, Re: Shutter Installation 9400 S. Ocean Dr. (#305B) Jensen Beach, FL 34957 To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2014 for the installation of accordion shutters at the above referenced address. Wind speed: Vuit: 165 mph,Vasa: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 72"Maximum Height Shutter Location: Rear of Unit (Roll up) Required Design Pressure: +47.8 /-63.3 PSF Zone5(worst case) Shutters to be installed shall be equal to, or exceed the required design pressures as listed above"Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2014. Shutters shall be FL# 17001.1 (Roll up) Shutter product design pressure: +/- 120 PSF per product approval. Thank you for your attention.to this matter. Submitted by: PAUL WELCH EIC. Paul Welch,P.E. - Reg.No 29945 _ - _