HomeMy WebLinkAboutProduct Approval (2)Business ♦ Professional
"Or"' Depargnent SCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts Publications FSC Staff SCIS Site Map ! Links Search
Busines //ll���)
Professi al Product
ro" Pblic User l
Renulation
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL9777-117
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg-keeter@owenscorning.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Zachary R. Priest
PE -74021
UL LLC
12/31/2020
Locke Bowden
r Validation Checklist - Hardcopy Received
FL9777 R7 CnT ()rR140n7.4A FBC 2014 Evaluation Rennrt Weathnrinck
Vnn-HVH7_ - kinal.ndf
ASTM D 1970
2009
ASTM G 155
2005
TAS 103
1995
UL 1897
2004
Product Approval Method Method 1 Option D
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/21/2016
Date Approved 06/08/2016
Summary of Products
Back Need
contact Ila :: 194n North Monne Street Tallahaeeoe FL 32399 PCnne[ SSO-497-1824
The State of Ronda Is an AA/EEO employe, convdnht 2897-2011 State of Florida.:: Privacy Statement :: Ac..INIIN Statement:: Refund Statement
Description
FL # Model, Number or Name
9777.1 Weatherlock G
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R7 IT OCR14002.4A FBC 2014 Evaluation Report
Approved for use outside HVHZ: Yes
Weatherlock Non-HVHZ - final.odf
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Report
Weatherlock Nnn-HVHZ - final,.'�df
Created by Independent Third Party: Yes
9777.2
Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9777 R7 II OCR14002.4A FBC 7014 Evaluatinn Reoort
Approved for use outside HVHZ: Yes
Wear-Non-HVHZ - final.ndf
Impact Resistant: N/A
Veri/led By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Reoort
Weatherlock Non-HVH7 - final.ndf
Created by Independent Third Party: Yes
9777.3 Weatherlock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R7 II OCR14002.4A FBC 2014 Evaluatinn Reoort
Approved for use outside HVHZ: Yes
Weatherlock Non-HVHZ - final.ndf
Impact Resistant: N/A
Verified By: Zachary R. Priest PE -74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R7 AF Of'11140n7.4A FRC 2014 Fvaluatinn Reoort
Ieatherlgck Npn-HVHZ - final.ndf
reated by Independent Third Party: Yes
9777.4 Weatherlock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL9777 R7 II 0(71114002.48 FBC 2014 Evaluation Reoort
Approved for use outside HVHZ: No
Wear�erlock Metal HVH7 - final.ndf
Impact Resistant: N/A
Verlfied By: Zachary R. Priest PE -74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R7 AE OCR14002.4B FBC 2014 Evaluation Reoort
Weatherlock Metal HVH7 - final.ndf
Created by Independent Third Party: Yes
9777.5
Weatherlock Specialty Tile B Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R7 R OCR14002.4A FRC 2014 Fvaluatinn Renort
Approved for use outside HVHZ: Yes
Weatherlock Non-HVHZ - final.ndf
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: +0/-105
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Reoort
Weatherlock Non-HVHZ - flnal.odf
Created by Independent Third Party: Yes
Back Need
contact Ila :: 194n North Monne Street Tallahaeeoe FL 32399 PCnne[ SSO-497-1824
The State of Ronda Is an AA/EEO employe, convdnht 2897-2011 State of Florida.:: Privacy Statement :: Ac..INIIN Statement:: Refund Statement
-4 GREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE 5T" EDITION (2014)
Manufacturer:
OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19, 2016
Standard
1 Owens Corning Parkway
PRI Construction Materials Technologies (TST6049)
Toledo, OH 43657
ASTM D 1970
(800) 438-7465
PRI Construction Materials Technologies (TST6049)
www.owenscornina.com
Manufacturing Location:
Brentwood, NH
Quality Assurance:
UL LLC (QUA9625)
SCOPE
1995
Category: Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5, 1507.4.5.2, 1507.5.3,
1507.5.3.2, 1507.7.3, 1507.7.3.2
Properties: Physical properties
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST6049)
NEI -039-02-01
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049)
NEI -042-02-01 REV2
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049)
NEI -045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
NEI -045-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST6049)
NEI -053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
NEI -053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST6049)
NEI -093-02-02
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049)
OCF-213-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST6049)
OCF-237-02-01
UL 1897
2004
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST6049)
OCF-252-02-01
ASTM D 1970
2009
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049)
OCF-272-02-01
TAS 103
1995
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock® G WeatherLock® G is an ASTM D 1970 self-adhesive undedayment constructed from SBS
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2 -sq. rolls with nominal dimensions of 3 -ft x 66.7 -ft.
WeatherLock® G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock® Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1 -
sq. rolls with nominal dimensions of 3 -ft x 33.3 -ft and 2 sq. rolls with nominal dimensions
of 3 -ft x 66.7 -ft.
WeatherLock® Mat is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
OCR14002.4A FL9777-R7 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
i,A TECHNICAL SERVICES, LLC
WeatherLock@ Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3 -ft x 66.7 -ft.
WeatherLock@
Specialty Tile & Metal
PRODUCT APPLICATION
WeatherLock@ Metal is permitted to be used with mechanically fastened asphalt
shingles, metal roof panels or shingles, wood shakes or shingles, and slate roofing as
prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90
days.
WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3 -ft x 71.3 -ft.
WeatherLock@ Specialty Tile & Metal is permitted to be used with mechanically fastened
asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or
shingles, and slate roofing as prescribed in the FBC. WeatherLocke Specialty Tile &
Metal is permitted to be used with adhered clay or concrete tile roofing using either 3MTM
2 -Component Foam Roof Tile Adhesive AH -160 (3M Company) or TILE BONDTm Roof
Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited
to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
Min. Roof Slope: 2:12 or in accordance in with FBC
Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the save, starting at the eave, and with minimum 3" side
laps and minimum 6" end laps staggered 6 -ft. from preceding course. End laps for
WeatherLock@ Specialty Tile & Metal shall be primed with ASTM D 41 primer or sealed
with asphalt roof cement a minimum of 3-4 inches across the width of the lap.
It is permissible to nail the underlayment 18 -inches on -center as needed (nails shall be
installed perpendicular to deck with the nail heads flush to the top surface of the
undedayment). WeatherLock@ Specialty Tile & Metal shall be back nailed when
installed on roof slopes greater than 3:12.
For valley applications, the roll shall be applied centered along the valley prior to
installing the underlayment at the eave. For eave protection, the underlayment should
extend to a point 24 -inches inside the exterior wall.
The underlayment shall be installed over metal drip edge at the eave, and under the drip
edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible
to install the underlayment under the drip edge in accordance Section 1507.2.9.3.
Min. Application 40"F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
OCR14002.4A FL9777-R7 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
WIND RESISTANCE
The Maximum Design Pressures shown below were Calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlavment Svstem No.1
Roof Deck: Min. 15/32 -inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1 -1/4 -inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1 -5/8 -inch 0 tin caps spaced 12" o.c. The applied
undedayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -105 psf
Pressure:
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be property ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The undedayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
OCR14002AA FL9777-R7 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockO Self -Sealing Ice & Water Barriers
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 5w Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer.
ti.
No 74021
ir
:90: STATE OF
'4'9/0NAi i!�%%
CERTIFICATION OF INDEPENDENCE
2016.04.19
15:51:11
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002AA FL9777-R7 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.