Loading...
HomeMy WebLinkAboutProduct Approval axis d- Rorlda WNIIZAI BCIS Home Login i User Registration 'Hot Topic I Submit Surcharge Stats fl Facts Publications j FBC Staff f SCIS Site.Map l Links ? Search \. .r° Product Approval USER:Public User Prtxfirt nnn n0l Menu>Product or t;nplication Search>Acolicatinn LiSj>APPIIeaHon-0etail 4$ FL# FL1956-1112 Application Type Editorial Change Code Version 2014 Application Status Approved *Approved by DBPR:Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko:com Authorized Signature Kerri Eden kerri_eden@tamko:com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerneden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By Robert I*M.Nleminen,PE Validation Checklist Hardcopy Received Referenced Standard and Year(of Standard) dar Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 09/17/2015 Date Validated 10106/2015 Date Pending FBC Approval Date Approved 10/09/2015 Summa ry of Products TL# Model,Number Desci 1ption or Name 1956.1 Elite Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In FL1956 R12 C CAC FL1956 R11 C CAC Tamko SeryConf FL Wk-1al-5-PAf HVHZ*No FL1956 R12 C C&(Z-UL cgr, Cifiooil11 1 df IL _ : Approved for use outside Quality Assurance Contract Expiration Date HVHZ,Yes 09/17/2018 Impact Resistant,N/A Installation Instructions Design Pressure.N/A F11956 R12 11 Glass Seal Other:Asphalt shingles Verified By:Robert Nieminen 59166 shall be used only on roof Created by Independent Third Party:No slopes of 2:12 or greater. Evaluation Reports Nails must be used as:the Created by Independent Third Party: method of attachment. 1956.2 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In FL1956 R12 C CAC FL1956 R11 CSC Tamko Sery Con FL 1256 2015Zdf HVHZ:No FL1956 R12 C-CAC 4A.. certification_10-. df Approved for use outside Quality Assurance Contract Expiration Date HVHZ.*Yes .09/17/2018 Impact Resistant.NIA Installation Instructions Design Pressure.N/A F11956 R12 11 Gla . Seal Elite Glass Seal w a InatQdIf Other:Asphalt shingles Verified By:Robert,Nleminen PE 59166 shall be used only on roof Created by Independent Third Party:No slopes of 2:12 or greater, Evaluation Reports Nails must be used as the Created by Independent Third Party: method of bttachm6nt. 1956.3 Heritage A I dimensional asphalt.shingle. Limits of Use Certification Agency Certificate Approved for use in FL19S6 P I? C CAC 1`1_1956 R11 C, _CAC Tamko c,;ery Coof[L_j9j5_2_0_1S_.p_df HVHZ:No M-1256 R12 ECAC 111- Certification .10-11-12.ndf Approved for use outside Quality AssuranceContract Expiration Data HVHZ.*Yes 09/17/2018 Impact Resistant:N/A installation Instructions Design Pressure.N/A FI1956R12 It Rage D F I L3apps ins pdf Other:Asphalt shingles FL1956 R12 11 Heritage F ago inst.ndf shall be used only on roof R-1956 812 11 Heritage T ago inst,pdf slopes of 2:12 or greater. Verified BY:Robert J.M.Niemiden FL 59166 Nails must be:used as the Created by Independent t Third Party:No method ofattachment, Evaluation Reports Created by Independent Third Party: T95157A [Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In FL1956 R12 C CAC FL1956 Rif C QAC Tamko Sery Cont FL 1.956 2015,pd. HVHZ:No FL1956 R12 C CAC [JL cf,-.rtifcat16n 10w11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant-N/A Installation Instructions Design Pressure:N/A F0956 R12 11 heritane'30 aon Inst aprd IO.Ddf Other.Asphalt shingles FL1956 R12 11 heritage 0 app Inst f-april 10.od shall be used only on roof Verified By:Robert NlemInen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party:No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: :197567.5tHeritage 50 A.dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in fLjR5LBj2_C_ A L-1.956 R11 C CAC 7a MkQ_5gry CqqE&1g56201 ) 5,Lfff HVIiZ.No FL1956 R12 C CAC UL certificarign 1k-.Uz1_Zprif Approved for use outside Quality Assurance Contract Expiration Date HVHZ,Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 TJ heritage 50 app Other:Asphalt shingles FLI". 6,R12 T heritaue SO ano inst f anril 10.ndf shall be used only on roof Verified By:Robert Nlemlnen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party:No Nails must be used as the Evaluation Reports method of attachment. Created-by Independent Third Party., UL September 17,2015 Tamko Building Products 220 W 4th Street PO Box 1404 Joplin,MO 64801 Contact Name: Kerr!Eden Email Address: Kerri Edenatamko.com Subject: UL Third Party Inspection Service for Florida Quality Assurance Expiration Date: September 17,2018 Reference: UL' Order 10966260 Dear Ms.Eden: This letter is to confirm.that Tamko Building Products has an agreement with UL LLC to conduct audits at your plant to verify Florida Quality Control requirements at the'f0owing locations: Tamko Building Products Tamko Building Products Tamko Building Products 601 N. High.St 1598 Hwy 183 2300 3Vh St Joplin MO 64801 Phillipsburg KS 67661 Tuscaloosa AL 35401 Tamko Building Products Tamko Building Products 7910 S Central Expy 4500 Tamko Dr .Dallas TX 75216 Frederick MD 21704 Quality Control System and Products will be inspected according to Florida Product Approval Report FL1956 to ensure the manufacturer's quality documentation is well defined,fully documented and effectively implemented. A minimum of two(2)inspections per year will be conducted. This service has been established under foe R2919. UL Ltr. 333 Piingsten Road,Natthbrook.It"60062-2096 USA T:847.272.8800/F:847.272.8129/W.ULCOM lf.you have any questions,please call me at 847-6643623. Wnd Tegards; (X LeAnna Gradecki Project Coordinator Product Safety Tel:847-664-3623 Fax:.847-51.3-7853 LeAnna.Gradeckif'7ul.com UL LLC 333 Pfingsten Road Northbrook, IL 60062-2096 USA M: 847-6.64-3623 LeAnna.Gradecki@ul.com October 11 2012 Tamko Building Products Inc Ms.Kerri Eden 220 W 4th St PO Box 1404 Joplin,MO 64801 RE: TAMKO Shingles Dear Ms.Eden: This is to confirm that the attached shingle matrix pertains to Tamko produced shingles. All the products have been tested and meet the criteria for the standards mentioned. They are covered by UL's Follow-Up Service Program under Tamko's File R2919. The Listing Mark of Underwriters Laboratories Inc. on the product is the only method provided by UL to identify products manufactured under its Listing and Follow-Up Service. Combination Listing/Classification Mark.—.A Listing Mark combined-with a Classification Mark is provided on products that have additionally been investigated in accordance with various supplemental standards. Please refer to the labels on the product. "Should you have any questions,.please feel free to contact the writer. Very truly yours, Reviewed.By:. ezgolv William G Marshall(Ext. 42735) Alpesh Patel (Ext.42522) Sr. Engineering Associate Staff Engineer Fire Protection.Division 301.9A Fire Protection Division 3019A �L M20 Shingle Yatrix iaillinsbuzg, RS Frederick, 1H7 Product Son AM Ate! ATFL UL MY C.A Product N= =iSTUR ism "v UL ASS: CSA, DUG D3161 D5351 ^1290 137158 122.5. D2462132161' D6281. 239.0 D7158 122.5 Clazz Clazz Claes Claea Clazz Clazz Clazz Clazz F H & H £ A A H Fxlasa-Seal (3R) Glazq-Seal (24( x X x X x Elite Glan-Seal (AR} elite Glasq-Seal (AR) x x x x x Heritage x x x x x x Heritage x X x x x x Heritage 30 (&R( x x x x xx Heritage 30 (ARI x x X x X x Heritage XL (AR) Heritage RT. (An$ x X - - - Heritage Woodgate X X - - - Heritage 50 (AR) x x x x x x Heritage 30 aR) x x' x x x x Eeritage Premum k x x x x x Heritage Premi= x x x X x x Heritage vintage (ARI, x x x x x X Heritage Vintage (3R) Y,eritage Vintage :t. A ---- ---- ---- 12-1/4 x'12 Hip and Ridge x x 12 X 12 Hip and Ridge Dallaz, TX Tuscaloosa, 33 Product*Name FST'( alu- 3M UL &STS» M. UL Product Hare AST:i ASTM MTM' UL 39TH C33 D2462 D2161 DESK 2290 D7158 122.5 2218 D39E2 U2161 D6251 2390 D7155 123.5 Clazz Clazz Clazz Class Clash Clans Claaa Clazz H H H F F H H aiase`Seal (AR) Glazz-Seal (AR) x x X x x Elite Glazz-Seal (ER} Elite 91aas-Seal (29) x X x X X Heritage X x x x X. X Heritage x X x x x x Heritage 20 (AR) x x x x x x Heritage 20 (AR: x x x x x x Heritage 5M [AR) X x x x x Heritage 3M (AR) Heritage 'Aoocgate x x x X x x Heritage 50 DRY x x x x x x Heritage 50 (AR! X x x x x x Heritage Prmium x X x x x x Heritage Premium x x x x x X Heritage iinage (BR} Heritage vintage (IR) Heritage 3R K X X ri X X. 12 X 12 Han and Ridge x x -- "'- ---_ Joplin, IM Product Nave ASTM D302 AffM:D3 I fil DE38L UL 2390 MIMI D715e CSA Class F Class R Class H Class H 123.5 Glass-seal JAR) x x x Elite Glaas-Seal (AR) x x x x x Heritage x x x x x x Reritage 10 (AR) x x x x X. x Heritage XL (.AR) Heritage 50 (AR) Heritage Premium Heritage Vintage (AR) 12 X 12 Hip and Ridge x x ---- x 1:2 Hip f. Ridge x x MTAELITE GLA S4EALO w.11­11 K0 GLASS-SEAL BUILDING PR0®tICTS 3-TAD ASPHALT SHINGLES Frederick, MD o Joplin, MO•Tuscaloosa,AL THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS. THIS PRODUCT iS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. 1N COLD WEATHER(BELOW 4WIZ),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE.6DGES AND CORNERS OF THE SHINGLES. IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles. I.Boor iDiCH 3.ff'ASTCNERS These shingles are for application to roof decks consisting of NAILS:TAMKO recommends the use of nails as the preferred plywood or sheathing boards capable of receiving and retaining method of application. fasteners,and to inclines of not less than 2 in.per foot.For roofs WiND CAUTION: Extreme wind velocities can damage these having pitches 2 in. per foot to leas than 4 in, per foot, refer to shingles after application when proper sealing of the shingles does special instructions titled"Low Slope Application".For roofs having not occur.This can especially.be a problem if the shingles are pitches greater than 21.in.per foot,referto special instructions titted applied in cooler months or in areas on the roof that do not receive "Mansard Roof or Steep Slope Roof". Shingles must be applied direct sunlight.These conditions may impede the sealing of the properly. TAMKO assumes no responsibility for leaks or defects adhesive strips on the shingles.The inability to seal down may be resulting from improper application,or failure to property prepare compounded by prolonged cold weather conditions and/or blowing the surface to be roofed over, dust.to these situations.hand seating of the shingles is required.To insure immediate sealing,apply 4 quarter-sized dabs of TAM-PRO' NEW ROOF DECK CONSTRUCTION.Roof deck must be smooth, Premium SBS Adhesive or TAMKO Tam-Seal Adhesive on the back dry and free from warped surfaces.It is recommended that metal of the shingle 1.in.(25mm)and 13 in.(330mm)in from each side and ddp edges be installed at eaves and rakes. 1 In.(25mrri)up from the bottom of the shingle.Press shingle firmly PLYWO.QO;Ail plywood shall be exterior grade as defined by the into the adhesive.For maximum wind resistance along rakes,cement Engineered Wood Association. a ext ri shall e a minimum of the shingles to the undedayment acid each other in a 4 in.(102mm)width in,thickness and applied in accordance with the recommendations of TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive,Caution: Appy ONLY a,thin uniform layer of adhesive lass than 118 in.(3mm) of the Engineered Wood Association. thick.Excessive amounts can cause blistering of the shingles and SSHEATHiN-B RD : Boards shall be well-seasoned tongue- may soften the asphalt in certain underlayments resulting in the and-groove boards and not over 6 in.nominal width.Boards shall asphalt flowing,dripping and staining.Shingles must also be fastened be a 1 in.nominal minimum thickness. Boards shall be properly according to the fastening instructions described below. spaced and nailed. Correct placement of the fasteners is critical to the performance of the shingle. if the fastenersarenot placed as shown in the a.YBHTil ATION diagram and described below,this will result in the termination of Inadequate ventilation of attic spaces can cause accumulation of TAMKO's liabilities under the limited Warranty.TAMKO will not be responsible ler damage to shingles caused W winds in excess of moisture in winter months and a build up of heat in the summer. the applicable mph as stated in the Limited Warranty.See Limited These conditions can lead to: Warranty.for di3tails. 1.Vapor Condensation FASTENING PATTERNS:Fasteners must be placed above or below 2.Suckling of shingles due to deck movement. the factory applied sealant in an area between 5-518 in.and 6-718 in.from the butt edge of the shingle.Fasteners should be located 3.Rotting of wood members. horizontally according to the diagram below. Do not nail into Lthe 4..Premature failure of roof. sealant.TAMKO recommends nailing below,the.sealant whenever possible for greater wind resistance. To insure adequate ventilation and circulation of air,place louvers 1)Standard Fastening Pattern.(For use on decks with slopes 2 of sufficient size high in the gable ends and/or install continuous in.per foot to 21."in..per foot.).One fastener 1 in..back from each ridge and soffit vents. FHA minimum property standards require end and one 12 in.back from each end of the shingle for a total one square foot of net free ventilation area to each 150 square feet of 4 fasteners.(See Standard Fastening Pattern illustrated below). of space to be vented,or one square foot per 300 square feet if a NAILS vapor barrier is installed on the warm side of the ceiling or if at least _ ;_t ✓ j one half of the ventilation is provided nearthe ridge.,if the ventilation openings are screened,the total area should be doubled. Nniring + - �_�� \ 1� =r 6,7V Area IT iS PARTICULARLY IMPORTANT TO PROVIDE IT, Wig• ADEQUATE VENTILATION Butt Edge (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 12M Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 600-228-2656 tat'ko.com Southwest District, 7910 S.Central Exp.: Dallas,TX 75216 800-443-1834 Western District 5300 Cast 43rd Ave., Denver,CO 80216 800-530-8868 b S 16® (CONTINUED from page 1) E161E 016A DI1K0, 616Ass-snij 116DING PRODUCTS 3-TWASPRALT SHINGLES Frederick, MD •Joplin, MO•Tuscaloosa,AL 2) Mansard Fastening Pattern.(For use on decks with slopes 4.UNDERLAY greater than 21 in.per foot.)One fastener 1 in.back from each end UNDERLAYMENT An underlayment must be applied over the and one fastener 10-112 in.back from each end and one fastener entire deck before the installation of TAMKO shingles.Failure to add 13-1/2 in.back from each end for a total of 6 fastener per shingle. underlayment can cause premature failure of the shingles which.is (See Mansard Fastening Pattern illustrated below.) not covered by TAMKO's Limited Warranty. MANSARD FASTENING PATTERN Products which are acceptable for use as underlayment are: NAILS a, _ ,_1 � ,i'`'! � 1 Asphalt Sat4t_rate�i FeiS_iJnderla�menfs, r ,f cr • TAMKO No,15 Asphalt Saturated Organic Felt Nailing a. ' ' �-; ~ 6.718" • Any TAN1KO non-perforated asphalt saturated organic felt Area `= �.. .,ti. . I • Anon-perforated asphalt saturated organic felt which meets ! 5-518" ASTM:D226,Type I or 11 or ASTM D4869 Butt Edge rlaymonls • Tam-Shield;Synthetic Underlayment .4AILFA;TAMKO recommends the use of nails as the preferred method . TAMKO TW Metal and Tile Underlayment,TW Underlayment of application. Standard type roofing nails should be used. Nall and Moisture Guard PlusO(additional ventilation may be shanks should be made of minimum 12-gauge wire,and a minimum required. Contact TAMKO's Technical Services Department head diameter of 316 in.Nails should be long enough to penetrate for more information:) 3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick; the nails should be long enough to penetrate completely through plywood decking and extend at least 118 in.through the roof deck. For As„pt maturated Feit 11r�c erlamapts Drive nail head flush with the shingle surface. Apply the felt when the deck is dry.On roof decks with slopes 4 in.per foot and greater apply the felt parallel to the eaves Properly Driven Improperly Driven lapping each course of the felt.over the lower course at least !gym•m�ate.. Maa a„v," PYG d(YP «ooYPd 2 in.Where ends join,lap the felt 4 in,If left exposed,the felt AsphAt may be adversely affected by moisture and weathering.Laying of the felt and the shingle application must be done together. it TS �� - Uac1a P ___ _�.. �"01q"� amm— V For All Other:SpecJ„ajjy.Underlayrnents: oWjM,Vc dPCM"tiWN INWeeuato 1_'k j"CU% Wdati my .011.4wmwhq+es.dx rtP" a,Pgbnst* xotlNagg On roof decks with slopes;4.1n; per foot.and greater apply the underlayment parallel to the eaves in accordance with underlayment written application instructions. The STAPLES:If staples are used in the attaching process,follow the underlayment should not be left exposed for a longer period of above instructions for placement.Ail staples must be driven with time than is specified in the underlayments written application pneumatic staplers.The staple must meet the following minimum instructions.The final roof covering must be installed before dimensionaLrequirements.Staples must be made from a minimum the structure is exposed to adverse weather conditions,such 16 gauge galvanized wire.Crown width must beat least 15/16 in. as wind driven rain,high wind,hail,ice storms,etc. (staple crown width is measured outside the legs).Leg length should be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for In areas where ice builds up along the eaves or a back-up of water reroofing thus allowing a minimum deck penetration of 3/4 in.The from frozen or clogged gutters is a potential problem,TAMKO's crown of the staple must be parallel to the length of the shingle. Moisture Guard Plue,TW Metal and Tile Underlayment or TW The staple crown should be driven flush with the shingle surface. Underlayment(or any specialty eaves flashing product)may be Staples that.are crooked,_underdriven or overdriven are considered applied to eaves,rakes,ridges,valleys,around chimneys,skylights improperly applied. or dormers to.help prevent water damage. Contact TAMKO's Properly Driven Improperly DrivenTechnical Services Department for mora information. i.=.� undtlydrivm mwrdmm acdr d Substitute products as shingle underlayment should not be used. `-=Ias §71 INS UT_"- DO NOT FASTEN INTO THE FACTORY APPLIED ADHESIVE. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 WU Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tcamko.com Southwest District 7910 S.Central Exp.. Dallas,TX 75216 800-443-1834 Wester District 5300 East 43rd Ave., Denver,:CO 80216 800-530-8868 [T:A f4 KEhITE 016AMEA16 (CONTINUED from page 2) 0 G16A SS-SEAL BU1160ING PRODUCTS MAR AS PHA16T GWING16ES Frederick, MD o Joplin, MO•Tuscaloosa, AL 0.APPLICATION IidSTRUCTIONS 8.RE-ROOFING START RU.9_V,8SE.Astarter course may consist of TAMKO Shingle Beforete-roofing,becertainto inspect theroof decks.Ali plywoodshall. Starter.self-sealing 3-tab shingles or a 9 inch wide strip of mineral meet the requirements listed in Section 1. surface roll roofing.If self-sealing 3-tab shingles are used,remove the exposed tab portion and install with the factory applied adhe- Nail down or remove cuded or broken shingles from the existing roof. sive adjacent to the eaves.Attach the starter course with approved Replace all missing shingles with new ones to provide a smooth base, fasteners along a line parallel to and 3 in.to 4 in,above the eaves Shinglesthatare buckled usually indicate warped decking orprotruding edge.The starter course should overhang both the eaves and rake nails.Hammer dorm all protruding nails or remove them and refasten edges 114 in.to 318 in.If a roll roofing is used,seat down the shingles In a neva location.Remove all drip edge metal and replace with new in the first course by applying adhesive cement in four spots equally spaced to the surface of the starter strip and press the shingledown If re-roofing over an existing roof where new flashing is required to on the spots of cement.Plastic cement should be used sparingly, protect against ice dams(freezelthaw cycle of water and/orthe backup as excessive amounts may cause blistering, of water in frozen or clogged gutters),remove the old roofing to a point at least 24 in.beyond the interior wall line and apply TAMKO's Moisture (CATiON:There are three different offset methods for Guard Pause waterproofing undedayment.Contact TAMKO's Technical applying stripshingles:the 4-inch method,the 5-Inch method and the Services Department for more information. 6-inch method.By removing different lengths from the first shingle, cutouts in one course of shingles do not fine up directly with those of The nesting procedure-described below is the preferred method for re- the course below.It is recommended that the shingles be laid accord- roofing over square tab strip shingles with a 5-1 t8 in.exposure. ing to one of these methods consistent with procedures outlined in ARMAs Residential Asphalt Roofing Manual.This panel will feature the Stitdff Qa{t w Begin by rising TAMKO Shingle Starter or by cutting 4-inch method.For information regarding the other methods,please shingles into 5-1l8x36inch strips.This isdonebyremoving the 5-1/8in. refer to the ARMA Residential Asphalt Roofing Manual. tabsfrom the bottom and approximately in.from the top ofthashingles CAUTiON:Never use an alignment system where shingle joints are so that the remaining portion is the same width as the exposure of the closer than in:to one another old shingles.Apply the starter piece so that the self-sealing adhesive 2"top tap lies along the eaves and is even with the existing roof.The starter strip Dnp adge ` undadayment _ y Dern should be wide enough to overhang the eaves and carry water into the ' Y,,A gutter.Remove 3 in.from the length of the first starter shingle to ensure "Eaves llastu. ............ -~"".""`. ...�.•:-_- \;>:, nr required in lou or that the joints from the old roof do riot align with the new. •�?�-"_ - 1� a'end tap au � 3 i t9 \ti, adh sN9 fr1.1f3 y,kti%"c' ,•� raaft N y,a�asare First Cour ;Cut off approximately 2 in.from the bottom edge of the shingiessathattheshngiesfit tafhtheexisting third course and align o°p edge with the edge of the starter strip.Start the first course.with a full 36 in. vriih8'rernared �tv}i : '^""� .' •^%rte TAWOStarterSlzingte - ,�. long shingle and fasten according to the instructions printed in Section 3. ..i�,. :,�.� ,,.a'r,;,,•r<:.,,SiiingW:Mrt.Rh:tttg dd edge V11toWe i ~~~;" Existing shingtns.. Stasi 2nd arse k 'Start tat coune ve �,,. '',•,• „a ' Yw✓f. r v�"r iAth full shingle %ith 4'remaved � •� B.LOW SLOPE APPLICA' ION On pitches 2.in.per foot to 4 in.per foot cover the deck with two layers of undettayment.Sagan by applying the undertayment in a 1/2-sheet width along the eaves and overhanging the drip edge : ` ! by 1J4 to 3f4 in.Place afull-shrset width over the 1/2-sheet width Drip ea7°' °L rr`✓ starter piece,completely Overlapping it,All succeeding courses will riP edge be positioned to overlap the preceding course by 1/2-sheet width.If Now shingles' . r% winter temperatures average 26°F or less,thoroughly cement the laps of the entire undedayment to each other with TAM-PRO or TAMKO r -a-exposure Plastic Root Cement from eaves and rakes to a point of a least 24 in, exposure i s '" inside the interior wall fine of the building.As analternative,TAMKO's Moisture Guard PlusP self-adhering waterproofing underlayment may be used in lieu of the cemented felts. SecandandSucceedinnCaursgst..According tothe offset application 7.MANSARD ROOF OR STEEP SLOPE ROOF method you choose-to use,remove the appropriate length from the rake end of the first shingle in esucceeding course.Place the top If the slope exceeds 21 in. per foot(601,each shingle must be edge of the new shingle against the butt edge of the old shingles in the sealed with TAM-PRO SBS Adhesive or TAM KO Tam-Seat Adhesive courses above.The full width shingle used on the second course will immediately upon installation.Quarter-sized dabs of cement must, reduce ft exposure of the first course to 3 in.The remaining courses be applied to shingles with a 5-1/8 in.exposure,use 6 fasteners per will automatically have a 5-118 in.exposure. shingle.See Section 3 for the Mansard Fastening.Pattern. (L`Dntinued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 12v12 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,(AD 21701 804-368-2055 Southeast District 2300 35th St„ Tuscaloosa,AL 35401 800-228-2656 tamkO.com Southwest District 7910 S.Central Exp:, Dallas,TX 75216 800-443-1834 Westem District 5300 East 43rd Ave., Denver,CO 80216 800-530-8888 3 E161TE 016 SS-SEAW (CONTINUED from page 3) 01SS-SFAIm BUILDING'PRODUCTS XTAB ASPHALT SHINGLES Frederick, MD i Joplin,NO -Tuscaloosa, AL, 9.UAURY APPLICATION 10.HIP AND IIMBE FASTENING DETAth Over the shingle underlayment,center a minimum 36 In,wide sheet Apply the shingles with a 5-1 f8 in.exposure beginning at the bottom of Moisture Guard Pluse or a minimum 50 Ib,roll rooting In the valley. of the hip or from the end of the ridge opposite the direction of the Nail the underiayment only where necessary to hold it in place and prevailing winds.Secure each shingle with one fastener 5-5/8 in. then only nail the outside edges. back from the exposed end and 1 In.up from the edge.Do not nail IMPORTANT-.PRIOR TO INSTALLATION WARM SHINGLES TO directly into the sealant. PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING TAMKO recommends the use of TAMKO Hip&Ridge shingle SHINGLES TO FORM VALLEY. products.Where matching colors are available,it is acceptable to After valley flashing is in place: use TAMKO's Gfass-Seal or Elite Glass-Seal shingles cut down to Apply the first course of shingles along the eaves of one of the 12 in.pieces. intersecting roof planes and across the valley; NOTE:Use only Shingles and Hip&Ridge shingles with the Algae Note.For proper flow of water over the trimmed shingle,always Relief feature on Glass-Seal or Elite Glass-Seal shingles with the start applying the shingles on the roof plane that has the lower Algae Relief feature. slope or less height. Fasteners should be 1/4 in.longer than the one used for shingles. • Extend the end shingle at least 12 in.onto the adjoining roof. IMPORTANT PRIOR TO INSTALLATION, CARE NEEDS TO BE Apply succeeding courses in the same manner,extending them across the valley and onto the adjoining roof. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE • Do not trim if the shingle length exceeds 12 in.Lengthsshouldvary. BENDING SHINGLES IN COOLWF-ATHER, o Press the shingles tightly into the valley, THESE ARE THE MANUFACTURER'S APPLICATION • Use normal shingle fastening methods. INSTRUCTIONS FOR THE ROOFING CONDITIONS Note:No fastener should be within 6 in.of the valley centerline, DESCRIBED.TAMKO BUILDING PRODUCTS,INC.ASSUMES and ttivo.fasteners should'be placed at the end of each shingle NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING crossing the valley. DEFECTS RESULTING FROM FAILURE TO FOLLOW THE • To the adjoining roof plane,apply one row of shingles extending MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW it over previously applied shingles and trim a minimum of 2 in. THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE back from the centerline of the valley. UNDER THE LIMITED WARRANTY. SEE THE LIMITED Clip the upper corner of each shingle at a 45-degree angle and WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS embed the end of the shingle in a 3 in.wide strip of asphalt plastic REGARDING THESE APPLICATION INSTRUCTIONS,PLEASE cement.This will prevent water from penetrating between the CONTACT TAMKO'STECHNICALSERVICES DEPARTMENTAT courses;by directing it into the valley, 800-641-4691• • CAUTION:Adhesive must be applied in smooth, thin, even layers.Excessive use of adhesive will cause blistering to this Directions of prevailing wind product.TAMKO assumes no responsibility for blistering, rstarts^exposure ifs wide sheet valleycentedins r�� Fastener of Moiswre Guard Pius No f»strnaB WWI 'a. "'��'•`G" or 60 .or heavier `} r`6'of eealariine roll roofing Edra fastener in . tinWdartaymant_,.:,.^^ sshspglC. 5"expo3ure .; Sena aratsiW ,at least 12'bayundnd TAMKO",Moisture Guard Plus",Tarr-Sfuate.'TA64-PRO'"and Elite Grass-Beef"are Asph3h pts^bc� valleycomeft e, resgistored wWemarks of TAMKO Biding Products,Ina earnest o9tconter Information included in these application insiructiertu was current at Irmo.01 printing. "..... ut45 ° TaaDtainacupyotlh;3mostcumetftversioetnf2hesusPA?icationixfhuctia5s,visitusonivse ;a."- .;°�.: --"".......-.....,..,.,..... at tamko,cvm.vr call Us at 8f10-Gfi1-4fi91. r" �Sh"n{itstst "Oe msc2"fk9ck" . ,.,•irvm valley sontOlin FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT 800-641-4651. Central District 220 West 4th St,, Joplin,Ma 64801800-641-4691 12112 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 23oo 35th st., Tuscaloosa,AL .35401 800-228-2656 tart ko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 6300 East 43rd Ave., Denver,CO 80216 800-530-8868 '�