HomeMy WebLinkAboutpermit applicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 03/01/2017 Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone; (772) 462-1553 Fax: (772) 462-1578 Commercial Residential 4
PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line
PROPOSED IMPROVEMENT LOCATION:
Address: 7905 Black Tern Dr, Port St. Lucie, FL 34952
Legal Description: EAGLE'S RETREAT AT SAVANNA CLUB (PS 42-24) BLK 54 LOT 8 (OR 3395-133).
Property Tax ID N: 3424-701-0024-000-7
Site Plan Name:
Project Name: WATER HEATER TANK REPLACEMENT
Setbacks Front Back: flight Side:
Left Side:
Lot No.8
Block No. 54
DETAILED DESCRIPTION OF WORK: 'll
REPLACE FAILED ELECTRIC WATER HEATER TANK IN LAUNDRY ROOM WITH NEW AO SMITH
30 GALLON TALL ELECTRIC WATER HEATER TANK.
CONSTRUCTION INFORMATION: .. III
I�I
CONTRACTOR:
Gas Tank
penmi-rnILK do
❑Gas Piping
Address: 7905 Black Tem Or
apply
City: Port St. Lucie State: FL
Zip Code: 34952 Fax: n/a
Phone No. 561-353-8303
Address: 1631 SW South Macedo Blvd
City: Port St. Lucie State: FL
Zip Code: 34984 Fax: 772-871-9069
Phone No. 772-871-9494
E -Mail: pie
Fill In fee simple Title Holder on next page ( if different
from the Owner listed above)
_Shutters
State or County License: CFC1426801
Windows/Doors
jjL',�JHVAC
11 Electric
Plumbing
Sprinklers
Generator
Roof Roofpitch
Total Sq. Ft of Construction:
S Ft. of First Floor:
Cost of Construction:$
975.00
Utilities:
Sewer ElSeptic
Building Height:
ER/LESSEE:
CONTRACTOR:
Name Phillip S. and Marie B. RIORDAN
Name: Robert W. LUDLUM
Address: 7905 Black Tem Or
Company: Benjamin Franklin Plumbing
P Y:
City: Port St. Lucie State: FL
Zip Code: 34952 Fax: n/a
Phone No. 561-353-8303
Address: 1631 SW South Macedo Blvd
City: Port St. Lucie State: FL
Zip Code: 34984 Fax: 772-871-9069
Phone No. 772-871-9494
E -Mail: pie
Fill In fee simple Title Holder on next page ( if different
from the Owner listed above)
E -Mail: pennits@bennfranklinplumbeccom
State or County License: CFC1426801
•• •-•-_ -• •...... .,1-10.. a ncwnucu nuuce In uummencemens is regwrea.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
--5tfte of Florida I
DESIGNER/ENGINEER:
Name:
Not App l icable
MORTGAGE COMPANY:
Name:
Not Applicable
Address:
XPIRES January 25. 2021
Address:
COUNTER
City:
Zip: Phone:
State:
City:
Zip: Phone:
State:
FEE SIMPLE TITLE HOLDER:
Name:
_ Not Applicable
BONDING COMPANY:
Name:
_Not Applicable
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or installation has commenced prior to the Issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
Inconsideration of the granting of this requested permit, 1 do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection ou intend to obtain financing, consult yvith lender orgy attorney before
commencing work or r Ing your Notice of CommeneeTnent4 / A / /
' -r— v S
SIAZ
e of rr r/Les a/Contractor as Agent for Owner Signature of racto se Holder
STATE OF FLORIDA / STATE OF FLORIDA p
COUNTY OF r 'il7 fJGC/�^ COUNTY OF cY,liil �_
The for oing instrument was acknowledged before me
thisydayof IIW46 .20/Z6y
(Name of person acknowledging)
(Signature of Nota .W, a of Florida I
Personally Known : py MRIO
'�A H�NAGNSDEZ
Type of Identigcati MSS
Commission No.
Revised 07/15/2014
The forgoing instrument was acknowledged before me
this _Z day of'20 ZZby
(Name of person acknowledging I
(Signature of N6taDLE:ub4
--5tfte of Florida I
Personally Known
IIWPr Rlhe I"DEZ
Type of ldentHcatio
'� MYCOMMISSIONMGO0a6469
SEATURTLE
XPIRES January 25. 2021
Commission No.
COUNTER
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEATURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
Co Smith, Residential Electric
Water Heaters
ENHANCED HEATING ELEMENTS CODE COMPLIANCE
• Dual 4500 watt elements for fast recovery • Meets UBC and ICC National Codes and
and reliable operation.' listed with CEC.
• Incoloy stainless steel lower element lasts • Complies with the Federal Energy
longer than a standard copper element. Conservation Standards effective
DYNACLEAN'"DIFFUSER DIP TUBE April 16, 2015, in accordance with the
Energy Policy and Conservation Act
• Helps reduce lime and sediment buildup (EPCA), as amended.
and maximizes hot water output. Made
from long-lasting PEX cross-linked
polymer.
HIGH ENERGY FACTORS
• Eco -friendly non -CFC foam insulation,
heat traps and other features combine
to yield a higher Energy Factor that
maximizes savings on operating costs.
COREGARD' ANODE ROD
• Our anode rods have a stainless steel
core that extends the life of the anode
rod allowing superior tank protection far
longer than standard anode rods.
BLUE DIAMOND- GLASS COATING
• Provides superior corrosion resistance
compared to industry standard glass
lining.
ENHANCED -FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid
brass, tamper resistant, enhanced -flow,
ball type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an integral screwdriver slot that
features a 1/4 turn (open/close) radius,
which not only permits full straight -
through water flow but also a quick and
positive shut off.
'Model ENL 30 her a single element.
APPROVED FOR MANUFACTURED
HOUSING
• All residential electric water heaters are
compliant with HUD Standards for mobile
homes/manufactured housing.
CERTIFIEDTO UL 174 FOR HOUSEHOLD
ELECTRIC WATER HEATERS
CSA CERTIFIED AND ASME RATED T&P
RELIEF VALVE
DESIGN -LISTED BY UNDERWRITERS
LABORATORIES
• Certified at 300 psi test pressure and 150
psi working pressure.
• Listed according to UL 174 standards
governing storage tank -type electric water
heaters.
6 -YEAR LIMITED TANK AND PARTS
WARRANTY
•
For complete information, consult written
warranty or go to hotwater.com.
M February 1016 X 0 Smith Corporation. All rights reservetl.
—hatwatermorn 1$00-527-1953To11-Free USA IA. Q Smith Corporation I SOO Tennessee Wapz Parkway I Ashland City, TO 37015
PERMIT SUBMITTAL DOCUMENTS
SP® UL
AOSRE50603
if,to Smith.
Residential Electric
Water Heaters
Model
Number
Gallon
fapaciry
First Hour
Ratio
Galb�
Energy
Factor
Recovery ®
90'f Rtse
Gallon Per
Hour
Element Watta a 340V
Dimensions in Inches
Approx.
Shlyy gg
Weigh[(Ibs1
Standard Maximum
A B C
Tall Models
Eli
30
41
0.95
21
A500
60W
46-1/2
39-112
19
95
ENT -4
40
51
09 5
21
4500
6000
60.114
53-014
20
118
ENTB-50`
50
]0
0.95
21
4500
6000
1 601/4
51-114
21
1 131
fNi-Sot
50
]1
095
21
4500
6000
60-1/2
51-114
22
134
ENT -55t
55
76
094
21
4500
6000
56112
48-112
24
1 145
Short Models
ENSB-30'
30
48
C.95
21
4500
6000
39
30P1i2
20
95
ENS 30t
30
49
0.95
21
4500
6000
39314
30-112
22
94
ENS 401
40
1
55
0.95
21
4500
1 6000
50
403/4
20-112
109
ENS -50t
50
62
0.95
21
4500
6000
49-314
40 die
23
161
Lai Too
Conned Models
ENL 20
19.5
NIA
NIA
21
4500
6000
30
21-1/4
20
65
ENLB-30'
28
40
0.95
21
4500
6000
30
21-3/4
22
96
-0t
ENL 3
28
43
0.95
21
4500
6000
31-114
21-314
24
115
ENLB-40a
38
46
0.95
21
4500
6000
31.314
24
24
118
ENL-4Of.
38
44
0.95
21
4500
6000
33-112
24
26
118
ENLB-50-t
48
57
0.95
21
4500
6000
34
25
26-I/2
1R
Mn1e314"w ...R.antan0"mole..
sid'iship with suppOed lemes, p, DlanAyl.
"a, lb yea lank and 6 yea, pdi .arantg Indiana E'lo'P'in To mode: human, leampa EN'30 becomes PNT301.
TInT&P Athan not available can the model.
zNL 20 isasingle element mnllgualion only
0,In,,II&P location 9315 used pn the EM -50 Pal ENT 55, EN540 and E.NS50
Top EST h at Am,l,ble on the 10 year model PN lO-50.
Dimensions and speuLcavons subject to mange wdish notice In a¢onlanre vuN ourpi of mains pmdu<l lmpmvemenl.
T&P VALVE
ACCESS
PANEL
ACCESS
PANEL
DRAIN
VALVE
A,Fabius, 2016 A 0 Smith Cotpoomon. All ilgm9 asaved.
www.M1oiwaiecmm 1800 5271953 Tolbfred OSA
PERMIT SUBMITTAL DOCUMENTS
ANODE (OR OPTIONAL
T&P LOCATION #1)
1 00 OPTIONALT&P
LOCATION #2
C O O JUNCTION
BOX
T&P VALVE
Is,, 2 of I
AOSRE50502