Wind Load Calculation
Castle WIN, Impact Windows FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS 70B9 Hemstreet Place West Palm Beach,Ft.33413 800.643.6371 Property Information Building Information Owner: McCLEARY,DAN Wind Zone: 165 MPH. Address: 3555 S.INDIAN RIVER DRIVE Exposure Category: D FORT PIERCE,FL 34982 Minimum Building Dimension: 30 ft. Mean Roof Height: 15 ft. JU Risk Category: H- Desi n Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 42.75 57.5 7 41.7 -45.4 2 Int 88.5 43.5 7 40.4 -44.1 3 Int 74 67.75 7 39.7 -43.4 4 Int 37 29.75 7 43.2 -46.9 5 Int 37 55 7 42.2 -45,.9 6 Int 74 43.5 7 41.0 -44.6 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.Sth Edition(2014)Florida Building Code. Page 1 of 1 Customer: McCLEARY WorkOrder Number: 02072017017 N0301 Unit No. Wall Opening Opening Shutter Shutter Slat Anchor Pressure Width Height Width Height Length Spacing 1 -45.4 42.75 43 53.75 48 44.75 9'b.c. 9"o.c. 2 -44.1 91.5 43 107.625 49.5 46.25 9'b.c. 9"o.c. 3 -43.4 74 67.75 92 72.75 69.5 9"o.c. 9"o.c. 4 -46.9 37 29.75 51.75 34.75 31.5 9"o.c. 9"o.c. 5 -46.9 37 55 51.75 60 56.75 9"o.c. To.c. 6 -44.6 74 43.5 92 48.5 45.25 9"o.c. 9"o.c.