Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutWind Load Calculation Castle
WIN, Impact Windows
FACTORY DIRECT SINCE 1969
COMPLETE HURRICANE PROTECTION SOLUTIONS
70B9 Hemstreet Place
West Palm Beach,Ft.33413 800.643.6371
Property Information Building Information
Owner: McCLEARY,DAN Wind Zone: 165 MPH.
Address: 3555 S.INDIAN RIVER DRIVE Exposure Category: D
FORT PIERCE,FL 34982 Minimum Building Dimension: 30 ft.
Mean Roof Height: 15 ft.
JU Risk Category: H-
Desi n Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 42.75 57.5 7 41.7 -45.4
2 Int 88.5 43.5 7 40.4 -44.1
3 Int 74 67.75 7 39.7 -43.4
4 Int 37 29.75 7 43.2 -46.9
5 Int 37 55 7 42.2 -45,.9
6 Int 74 43.5 7 41.0 -44.6
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.Sth Edition(2014)Florida Building Code.
Page 1 of 1
Customer: McCLEARY WorkOrder Number: 02072017017 N0301
Unit No. Wall Opening Opening Shutter Shutter Slat Anchor
Pressure Width Height Width Height Length Spacing
1 -45.4 42.75 43 53.75 48 44.75 9'b.c.
9"o.c.
2 -44.1 91.5 43 107.625 49.5 46.25 9'b.c.
9"o.c.
3 -43.4 74 67.75 92 72.75 69.5 9"o.c.
9"o.c.
4 -46.9 37 29.75 51.75 34.75 31.5 9"o.c.
9"o.c.
5 -46.9 37 55 51.75 60 56.75 9"o.c.
To.c.
6 -44.6 74 43.5 92 48.5 45.25 9"o.c.
9"o.c.