Loading...
HomeMy WebLinkAboutWind Load Calculation Castle Impact Windows FACTORY DIRECT SINCE 1969 A- COMPLETE HURRICANE PROTECTION SOLUTIONS 7089 Hemstreet Place West Palm Beach,FL 33413 800.643.6371 Property Information Building Information Owner: McCLEARY,DAN Wind Zone: 165 MPH. Address: 3555 S.INDIAN RIVER DRIVE Exposure Category: D FORT PIERCE,FL 34982 Minimum Building Dimension: 30 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in)_]L Height(in) Elevation(ft) Pressure(psf) Pressure(psf) IL1 Int. 37.5 49.75 7 42.5 -46.1 2 Int 37.5 49.75 7 42.5 -46.1 3 Int 74.75 49.75 7 40.5 -44.2 4 Int 74.75 50.5 7 40.5 -44.2 5 End 37.75 49.75 7 42.5 -56.4 6 Int 37.75 49.75 7 42.5 -46.1 7 Int 38.5 25 7 43.2 -46.9 8 Int 38 38.5 7 43.2 -46.8 9 Int 37.75 49 7 42.5 -46.2 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1 Customer: McCLEARY WorkOrder Number: 02072017017 N0302 Unit No. Wall Opening Opening Shutter Shutter Slat Anchor Pressure Width Height Width Height Length Spacing 1 -46.1 37.5 49.75 51.75 54.75 51.5 9"o.c. 9"o.c. 2 -46.1 37.5 49.75 51.75 54.75 51.5 9"o.c. 9'b.c. 3 -44.2 74.75 49.75 92 54.75 51.5 9"o.c. 9"o.c. 4 -44.2 74.75 50.5 92 55.5 52.25 9"o.c. 9"o.c. 5 -56.4 37.75 49.75 51.75 54.75 51.5 9"o.c. 9"o.c. 6 -46.1 37.75 49.75 51.75 54.75 51.5 To.c. 9"o.c. 7 -46.9 38.5 25 51.75 31.5 28.25 9"o.c. 9"o.c. 8 -46.8 38 38.5 44 43.5 40.25 9'b.c. 9'b.c. 9 -46.2 37.75 49 51.75 54 50.75 9"o.c. 9'b.c.