HomeMy WebLinkAboutProduct ApprovalOF
Business &Professional Reoulat ion
`r*
13CIS Home Log In I laser Registration Hat Toptcs I Submit Surcharge Stats & Facts Publications I FBC Staff . BCIS Site Map Links 1 Search
Product Approval
USER: Public User
Produet A--1 Menu > Product or AoDl—tion Search i A-1—ton ❑sl > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL10674-1112
Revision
2014
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg.keeler@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert I.M. Nieminen
PE -59166
UL LLC
08/20/2017
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL10674 R12 COI 2D16 01 COT Nipniinen.Ddf
Referenced Standard and Year (of Standard) Stagdard
ASTM D3161
ASTM D3462
ASTM D7158
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2009
2009
2008
Product Approval Method Method 1 Option D
Date Submitted
04/18/2016
Date Validated
04/19/2016
Date Pending FBC Approval
04/20/2016
Date Approved
06/08/2016
Summary of Products
FL # Model, Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ,. No FL10674 R12 iI 2Q15 04 FINAL _ER OC ASPHAI T
Approved for use outside HVHZ: Yes SHINGLES FL10674-RU pa
Impact Resistant: N/A Verified By: Robert J, M. Nieminen PE - 59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER, Section S. Evaluation Reports
FI -10674 R12 AE 2016 04 -FINAL ER OC ASPHALT
SHINGLES FL1Q674-R12.pdf
Created by Independent Third Party: Yes
sack Next
Contact us:: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA(EEO employer. Coovrlaht 2007-2013 State of Florida. ;; Ptivacv Statement :: Accessibility Statement Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditionai mail. If you have any questions, please contact 850.487.1395. *pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for off clal communication with the licensee. However email addresses are public record. It you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a Rcersee under Chapter 455, F.S., please
click here .
Product�A�pproval Accepts:
F_ 6g� iZ-1
Credit Card
safe
s
TRINITY ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization 1!9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 037940.02.12-R7
FL10674-R12
Date of Issuance: 02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Hobert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: p�S45e+tterrA,ri
et
i=
1L' The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M. Nieminen, P.E. i i..11 ].5. t 4 y. I .E. on 04/18/2016. This does not serve as an electronically signed
Florida Registration No. 59166, Florida DCA ANE1983 document. signed, sealed hardcopies bay been transmitted � the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/ Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard
Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462
2009
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161
2009
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7159
2008
R. REFERENCES:
Entity Examination Reference
Date
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3
02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453
05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263
04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308
02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137
02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532
02/10/2014
UL LLC (TST9628) Physical Properties Classification letter
02/13/2014
UL LLC (TST9628) Physical Properties Classification letter
10/02/2015
Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs
Various
UL LLC (QUA9625) Qua Iity Control Service Confirmation, R2453
Exp. 08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic' and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles.
4.1.2 Berkshire' are fiberglass reinforced, 4 -tab asphalt roof shingles.
4.1.3 Devonshire'" are fiberglass reinforced, 5 -tab asphalt roof shingles.
4.1.4 Duration', TruDefinition® Duration', Duration' Premium Cool, TruDefinition*
Duration' Designer Color
Collection, TruDefinition®Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgel Hip & Ridge Shingles are fiberglass reinforced, hip and ridge
asphalt roof shingles.
4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Rall are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 I' L10674-1112
Revision 7: 04/18/2016
Page 2 of 8
TRiNI-ry ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Va,d = 150 mph (V„ �t = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are
acceptable for use in all wind zones up to Vasd = 150 mph (Vr,it =194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
S.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61020-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asnhalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or 8905.2, with the following
exceptions:
➢ Berkshire' shingles require minimum five (5) nails per shingle.
➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle.
➢ Devonshire'' shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus;
Fekt undedaymentDeck Felt uru r-& ent Dad S&a ared
WeatherLodrP,
Self -adhered underlaymem
W'eatherLod&
wKierlay Ment ➢rip edge
Drip edge Drip
edge , eatae
- Naekr loeatetl
Mads located 2 —3' hum save
2"X' from gave
Install first Seff-sealing Adhesive irstst Sgkised rg pdAeve
rema
Starter st�r, �pp
positioned along gave a$Fx4 poslr�aaed along gave
shingle '=
6" rermoverl , " SW W Strip Plus uvsrharegs eaves and ,ak" 3 r4'-314^
Starter Strip shingle overhangs eaves and rakes , =: i
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
certificate ofAuthorization #9503 FL10674R12
Revision 7:04/19/2016
Page 3 of 8
6.2.6 Minimum Nailing— Classic" & Supreme:
- a .1
Normal
Mansard or
Area para
Wind Ares&High Wind
Area para Ylentaa normal.. Arens
desvnnes y
vientoa /uertws
t" I ," a
s"Exposure
Fxpoaici6n
6.2.7 Minimum Nailing--BerkshireO:
Sealant strip
La rka de se&adar
t" S 9vf° 9v±"sv2"
r �"
Standard Fastening Pattern
TRINITY ERD
Normal Mansard or Area porn
Wind Areas High Wind dasvarres y
Area pem vienras normele& Areas
vientas fwrtea
18 2.
1-1
5 511 " Exposure
Exposicl6n
Sealam strip
La Ova do sdladar
111 111111 11 f
Sealant ship
1 La tire de selladat
8 Vz- 8 7h"
r
1
6 -Nail Fastening Pattern
+, - cera. ■d1•s;'a
T Sof 9Yf 8YL BW.
1
1
T Atphap r4at9rgcement
Cemeato da taeW do astalta
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
Certificate ajAuthorlration #9503 FL10674-11 2
Revision 7:04/18/2016
Page 4 of $
6.2.8 Minimum Nailing—Devonshire'":
1 1
' n
5^518" exposure Sealant location
Exposid6n de 5 -518 pull; UbW6n del sellador
TRINITY ERD
Ten 1" Spots of Asphalt Roof Cement
Standard 6 -Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, Tru Definition Duration, Duration Premium Cool & Tru Definition Duration
Designer Color Collection:
4 -Nail Fastening Pattern
suroNa+f9 tasteni+,p ane x+dtl,
Haft, typical
Standard Fastening Pattern
Exterior Research and Design, U.C.
Certificate of Authorizotion #9503
6^tiair Fastening Pattern
summaRmtasmmng alta wide,
tee, iynicai
$} 6 -Nail Fastening Pattern
Fastening for Slopes Greater Than 21.12
s"�"Ha�+a"t.nln9 ",w wm+n
Fl, -
Wfl. rypwa,
nl +r +r
i
a+m^'aye^
f'wl+"spall OtMPw Roofinga wnt
Mansard or Steep Slope Fastening Pattern
r
Evaluation Report 1737940.02.12-R7
FL10674-R12
Revision 7: 04/18/2016
Page 5 of 8
Nails
Ten 1" Spots of Asphalt Roof Cement
Standard 6 -Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, Tru Definition Duration, Duration Premium Cool & Tru Definition Duration
Designer Color Collection:
4 -Nail Fastening Pattern
suroNa+f9 tasteni+,p ane x+dtl,
Haft, typical
Standard Fastening Pattern
Exterior Research and Design, U.C.
Certificate of Authorizotion #9503
6^tiair Fastening Pattern
summaRmtasmmng alta wide,
tee, iynicai
$} 6 -Nail Fastening Pattern
Fastening for Slopes Greater Than 21.12
s"�"Ha�+a"t.nln9 ",w wm+n
Fl, -
Wfl. rypwa,
nl +r +r
i
a+m^'aye^
f'wl+"spall OtMPw Roofinga wnt
Mansard or Steep Slope Fastening Pattern
r
Evaluation Report 1737940.02.12-R7
FL10674-R12
Revision 7: 04/18/2016
Page 5 of 8
TRINITY I ERa
6.2.1. Minimum Nailing — Tru Definition' Oakridge®, Oakridge®:
4 Nail P.dtarn
Esguemo con 4 cfavos
5518" Exposure Naas 5 519" Exposure
Fxposid6nde5516pulg. Cfavos €Xryosi4iande55/Opwg
Standard Fastening Pattern
9 Nail Pasttem
Esquema con 6 davos
5518" ExpasueV 5516" Exposure
Fxpadd6n de 55/8 palg Exposiobit de !i 5/8 pzdg.
6 -Nail Fastening Pattern
Fastening for Stopes Greater Than 21:12
sllf�lity!!l flSblNly Cri! WWUil�
N9u Typ"
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard' HP:
Exterior Research and Design, LLC,
Cerrijicare of Authorization #9503
sb& a& view
1A�s ilt:e�raf
Cirtil= Itr� IIJs
rii
Evaluation Report 037940.02.12-R7
FL10674-R12
Revision 7: 04/18/2016
Page 6 of 8
�t1
,\ TRINITY ERQ
6.3 HID & Ridge Shingles:
6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles and
ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of DuraRidgeT" Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
Fig. 1 4 q Fig. 2 —
F--. Ple�wnaVuna
Direction p Top Vi— SiteV ew
Mats A ? Nails MAN
TOP LaItWalen I `
4y
p I 1
I I J k 1 I i
p l I ! I I
1 1 I
Ergosure ,rte--� EI
I
I
6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Exterior Research and Design, U.C.
Certificate of Authorization #9503
Fig. C Hip & Ridge Shingle Faslening
Top V law
' Nails
,r
Nath
Evaluation Report 037940.02.12-R7
FL10674-1112
Revision 7.04/18/2016
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction SeaiantStrip
6' Ecposure
Fagan 714°
Cover Exposed
Fasteners with
Roof Cemard
�.# TRINITY ERQ
Standard ~1t'-- •
Fastening
Pattern kk
tr-a
it. i - Sealant
lily s• �
1 t2•
6.3.6 Minimum Nailing — puraRidgel Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
i4�.aina lMKad @itQti w
'�- S�taG ! wniaara di VOK
i7!fyEtiiGlr c�li+iMi4P (err�tti[�ixea
'Sap V* -
R
ti
i'
V" — p4m
V45ri ew�rwr
I'L
1
L
G�ou
-ti�aw�
1r rivil
4
..---s-
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE IENTITY:
UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037440.02.12-R7
Certificate of Authorization #9503 FL10674-1112
Revision 7: 04/18/2016
Page 8 of 8
'Sap V* -
i'
V" — p4m
V45ri ew�rwr
I'L
1
G�ou
4
..---s-
•_.._.
�. f1
Oreens GsrrMsy SurMlsr
I
I
I�
s�Sw
�
ibfi
I
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE IENTITY:
UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037440.02.12-R7
Certificate of Authorization #9503 FL10674-1112
Revision 7: 04/18/2016