HomeMy WebLinkAboutEngineering ^: PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772) 785 -9888 E-mail pwelchinc@aol.com March 6,2017 Re: Ward Re-Roof 939 Nettles Blvd. Jensen Beach, FL 34957 SCOPE OF WORK: Install new Metal Roof(Extreme Metal Fabricators,LLC "5-V Crimp"FL#17022.1)at above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT= 10'-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=3:12 SHAPE=PITCHED GABLE ADJUSTMENT FACTOR= 1.00 IMPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165MPH WIND,VELOCITY V asd= 128 MPH EXPOSURE=D ENCLOSURE CLASS =ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE(PSF): ZONE'l (Field)=-40.3 ZONE2 (Perimeter/Ridge)_ -68.0 ZONE 3 (Corners) _-99.8 Paul Welch Inc. Pa:u-Welch.P.E. Reg.No. 2994.5 =March 6,2017 939 Nettles Blvd Jensen Beach,FL - ;1 of 3 u METAL ROOFING ATTACHMENT REQUIREMENTS: Metal roofing to be attached with corrosion resistant Hex-Head wood screws#10 x 1 %" minimum with weather sealing washers(minimum 3/16"penetration through deck ). Fasteners shall be placed through the panel ribs at 12"on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING= 16"O.C. ZONE 2 (Perimeter/Ridge): FASTENER SPACING= 16"O.C. ZONE 3 (Corners): FASTENER SPACING=8"O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS'FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 &2: -93.5PSF/Zone 3: -10IPSF Therefore O.K. UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1,and FBC 15074.5.2.Underlayment shall be Tri-Built underlayment NOA# 15-1123.06. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL# 17022.1), (NOA# 15-1123.06.), manufacturer's specifications, and the Florida Building Code 2014. Paul Welch Inc. Paul Welch P.E. Reg.No.29945 March 6,2017 939 Nettles Blvd Jensen Beach,FL 2 of 3 Z 3 6AP,lti..2 i s4 _ 1 I 601.1 ROOF ZONE PLAN A=3' (1)=ZONE DESIGNATION('TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. Paul Welch Inc. Paul Welch P.E. Reg.No.29945 March 6,2017 939 Nettles Blvd Jensen Beach,FL 3 of,3