HomeMy WebLinkAboutMisc Letters (2) ,I r PARADISEEXTERIORS "Building Our Quality Reputation' One Customer At A Time SCC131150472 -Property Information BuildiAg Information Owner: WILLIAM&JEAN JUDD Wind Zone: 170 MPH. Address: 6603 DELAND AVE Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 29 ft. Mean Roof Height: 12 ft. Risk Category: �� II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width•(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 36 61 7 36.8 -40.0 _....__......- - - - .............. . _..- ---.— ......... ....._. .....----- ....... ..- - — .............. _ ........ __ - 2 Int 36 61 7 36.8 -40.0 3 Int 37 36 - 7 37.8 -41.0— -- -----......--- ................- - -......_.. - ....................._..- - .........---- ........ _._....._. -- _.... --- 4 Int 37 17 7 37.8 -41.0 5 Int 35 61 7 36.8 -40.0 .-.............--- -............................-- _..-.-.... - --- . ................_.. -..-........--- 6 End 35 61 7 36:8 -48.7 7 Int 35 36 7 37.8 -41.0 8 Int 35 _ 61 _ 7 36.8 -40.0 9 Int 35 61 7 36.8 -40.0 ii it Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1 .:i WINDOW & DOOR OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 1 Int window 7/8"Lami lG FL15780.3 45 50 36.8 -40.0 1 -54 x 76 36x61 YES No _. 2 Int window 7/8"Lami lG FL15780.3 45 50 36.8 -40.0 54x76 36x61 YES No 3 Int window V Lami IG FL13010.4 55 55 37.8 -41.0 48x72 37x36 No No 4 Int Window I"Lami IG FL13010.4 55 55 37.8 -41.0 48x72 37x17 No No 5 Int Window 7/1"Lami IG FL15780.3 45 50 36.8 -40.0 54x76 35x61 No No 6 End Window 7/8"Lami lG FL15780.3 45 50 36.8 -48.7 54x76 35x61 No No 7 Int Window 7/8"Lami lG FL15780.3 45 50 37.8 -41.0 54x76 35x36 No No 8 Int window 7/8"LamilG FL15780.3 45 50 36.8 -40.0 54x76 35x61 No No 9 Int Window 7/8"Lami lG FL15780.3 45 50 36.8 -40.0 54x76 35x61 No No