HomeMy WebLinkAboutProduct Approval 6/30/2015 Florida Building Code Online
x4r ,l.I."."q yy[y1
Flo,-:da Ceartmentq BCIS Home Log In User Registration ( Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links 'S�arcfi
Busines ? � j
Profession/al wd $ USER PubliccUNproval
F.
Regulation
Product Approval Menu>Product or Application Search>Aoolication List>Application Detail
I FL# FL1956-R11
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802 ".4
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By Robert J. M. Nieminen, PE
Validation Checklist- Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
https://floridabuilding.org/pr/pr_app00.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUh643ULv8xAB4z%2bKOdb010tBw%3d°/pad 1/4
6/30/2015 Florida Building Code Online
Date Submitted 03/20/2015
Date Validated 04/02/2015
Date Pending FBC Approval
Date Approved 04/06/2015
Summary of Products
FL# Model,Number Description
or Name
1956.1 Elite Glass-Seal. A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 Rll C CAC Tamko Sery Conf FL 1956 2012.pdf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
-Other: Asphalt shingles shall be FL1956 R11 II Glass Seal Elite Glass Seal apo inst ndf
used only on roof slopes of 2:12 Verified By: Robert Nieminen 59166 �.
or greater. Nails must be used Created by Independent Third Party: No
as the method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.2 Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.1)df
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall be FL1956 Rll II Glass Seal Elite Glass Seal apo inst.pdf
used only on roof slopes of 2:12 Verified By: Robert Nieminen PE 59166
or greater. Nails must be used Created by Independent Third Party: No
as the method of attachment. Evaluation Reports
Created by Independent Third Party:
I
J
56.3 Heritage A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.pdf
Approved for use outside FL1956 Rll C CAC UL certification 10-11-12.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall be FL1956 R11 II Heritage D F J P app inst.odf
used only on roof slopes of 2:12 FL1956 R11 II Heritage F app inst.pdf
or greater. Nails must be used FL1956 R11 II Heritage T app inst.ndf
as the method of attachment. Verified By: Robert J. M. Nieminen FL 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party: Y J
1956.4 Heritage 30 A dimensional asphalt shingle. I
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.1)df
Approved for use outside FL1956 Rll C CAC UL certification 10-11-12.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall be FL1956 Rll II heritage 30 app inst april 10.ndf
used only on roof slopes of 2:12 FL1956 Rll II heritage 30 app inst f anril 10.pdf
or greater. Nails must be used Verified By: Robert Nieminen PE 59166
as the method of attachment. Created by Independent Third Party: No
Evaluation Reports
.Created by Independent Third Party:
1956.5 Heritage 50 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 Rll C CAC Tamko Sery Conf FL 1956 2012.pdf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall be FL1956 R11 II heritage 50 app inst agril 10.odf
used only on roof slopes of 2:12 FL1956 R11 II heritage 50 apo inst f aoril l0.pdf
or greater. Nails must be used Verified By: Robert Nieminen PE 59166
as the method of attachment. Created by Independent Third Party: No
Evaluation Reports
hftps://floridabuilding.org/pr/pr_app_dU.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2bKOdbOlOtBw%3d%3d 2/4
I
6/30/2015 Florida Building Code Online
Created by Independent Third Party:
1956.6 Heritage Premium A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.ndf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.odf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions i
Other: Asphalt shingles shall be FL1956 R11 II Heritage Premium D P apo inst ndf
used only on roof slopes of 2:12 FL1956 R11 II Heritage Premium F apo inst.pdf i
or greater. Nails must be used FL1956 R11 II Heritage Premium T app inst.pdf
as the method of attachment. Verified By: Robert Nieminen 59166 f
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
......-... .—__.-....-— --- -- --- --- —---- --......-...----
1956.7 Heritage Vintage A heavy weight dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC FL1956 R9 C CAC Tamko Sery Conf FL 1956 2012.pdf
Approved for use outside FL1956 R11 C CAC UL shingle matrix.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall be FL1956 R11 II Heritage Vintage app inst.pdf
used only on roof slopes of 2:12 Verified By: Robert J. M. Nieminen PE 59166
or greater. Nails must be used Created by Independent Third Party: No
as the method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.8 Heritage Vintage Hip and ridge shingles
12 X 12 Hip and
Ridge
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC FL1956 R9 C CAC Tamko Sery Conf FL 1956 2012.odf
Approved for use outside FL1956 R11 C CAC UL shingle matrix.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall be FL1956 R11 II TAMKOn HeritageCp) 12 x 12 Hip and Ridge Application Instructions.pdf,�
used only on roof slopes of 2:12 Verified By: Robert J. M. Nieminen PE 59166
or greater. Nails must be used Created by Independent Third Party: No
as the method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.9 Heritage A dimensional asphalt shingle.
Woodgate
Limits of Use Certification Agency Certificate f
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.odf
-Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall be FL1956 R11 II Heritage Woodgate D app inst.pdf
used only on roof slopes of 2:12 FL1956 R11 II Heritage Woodgate F app inst.odf
or greater. Nails must be used Verified By: Robert Nieminen 59166
as the method of attachment. Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.10 Heritage XL A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.13df
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions i
Other:Asphalt shingles shall be FL1956 R11 II heritage A app inst d anril 10.odf
used only on roof slopes of 2:12 FL1956 R11 II heritage xl app inst f april 10.pdf
or greater. Nails must be used Verified By: Robert Nieminen PE 59166
as the method of attachment. Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.11 Hip and Ridge Hip and ridge shingles 1
Shingles
Limits of Use Certification Agency Certificate
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2bKOdbOlOtBw%3d%3d 3/4
6/30/2015 Florida Building Code Online
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012 Ddf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.Ddf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015 1
Design Pressure: N/A Installation Instructions I
Other: Hip and Ridge shingles FL1956 R11 II 12.25x12 HiD and Ridae.Ddf j
shall be used only on roof slopes FL1956 R11 II 12 x 12 HID Ridge ADolication Instructions.Ddf
of 2:12 or greater. Nails must FL1956 R11 II 12-1-4x12 HiDRidge Sealant Dab Illustrations.Ddf j
be used as the method of FL1956 R1I II 12x12 HiDRidge Sealant Dab Illustrations Ddf
attachment. Verified By: Robert Nieminen 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
F-71 Next
Contact Us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dick here.
Product Approval Accepts:
eClxsk .
]Lcurit vm z,i H7C'v
f
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2frnGFoyT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2bKOdbOlOtBw°/*3d%3d 4/4
® Application Instructions for FORMERLY HERITAGE®30
[T-A-M- KO HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Tuscaloosa, AL
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM
FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY
AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.,
IMPORTANT FASTENING INFORMATION: DO NOT PLACE FASTENERS ON OR ABOVE THE PAINT LINE ON THE SHINGLE. The paint
line on the shingle is the uppermost edge of TAMKO's expanded Nail Zone. For complete details regarding TAMKO's expanded Nail
Zone,see section 3 of these Application Instructions. Failure to follow fastening instructions,including but not limited to improper
placement of fasteners on or above the paint line,will adversely affect coverage under TAMKO's applicable Limited Warranty.Avoid
placing fasteners into the sealant strip.
IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles.
1.ROOF DECK area per 300 square feet if at least 40% and not more than 50%
of venting is provided not more than 3 feet below the ridge or if a
These shingles are for application to roof decks consisting of Class I or II vapor barrier is installed on the warm in winter side of
plywood or sheathing boards capable of receiving and retaining the ceiling in climate zones 6, 7, and 8 as recommended by the
fasteners,and to inclines of not less than 2 in. per foot. For roofs 2012 International Residential Code.For more information consult
having pitches 2 in. per foot to less than 4 in. per foot, refer to your design professional.If the ventilation openings are screened,
special instructions titled"Low Slope Application."For roofs having the total area should be doubled.
pitches greater than 21 in.per foot,refer to special instructions titled
"Mansard Roof or Steep Slope Roof." Shingles must be applied IT IS PARTICULARLY IMPORTANT TO PROVIDE
properly. TAMKO assumes no responsibility for leaks or defects ADEQUATE VENTILATION.
resulting from improper application, or failure to properly prepare
the surface to be roofed over. &FASTENERS
NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, WIND CAUTION: Extreme wind velocities can damage these
dry and free from warped surfaces. It is recommended that metal shingles after application when proper sealing of the shingles does
drip edges be installed at eaves and rakes. not occur.This can especially be a problem if the shingles are applied
PLYWOOD: All plywood shall be exterior grade as defined by in cooler months or in areas on the roof that do not receive direct
APA - The Engineered Wood Association. Plywood shall be a sunlight.These conditions may impede the sealing of the adhesive
minimum of 3/8 in.thickness and applied in accordance with the strips on the shingles.The inability to seal down may be compounded
recommendations of APA-The Engineered Wood Association. by prolonged cold weather conditions and/or blowing dust.In these
situations,hand sealing of the shingles is required.To ensure quicker
SHEATHING BOARDS: Boards shall be well-seasoned tongue- sealing, apply 4 quarter-sized dabs of TAM-PRO®SBS Flashing
and-groove boards and not over 6 in.nominal width. Boards shall Cement,TAMKO or TAM-PRO® Plastic Roof Cement,or TAMKO
be a 1 in. nominal minimum thickness. Boards shall be properly Tam-Seal Adhesive,meeting ASTM D 4586,Type 1,on the ba&of
spaced and nailed. the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and
1 in.(25mm)up from the bottom of the shingle.Press shingle firmly
2.VENTILATION into the adhesive.For maximum wind resistance along rakes,install
Iany TAMKO starter shingle including sealant or cement shingles to
Inadequate ventilation of attic spaces can cause accumulation of
the underlayment and each other in a 4 in.(102mm)width of TAM-
moisture in winter months and a build-up of heat in the summer. PRO® SBS Flashing Cement,TAMKO or TAM-PRO® Plastic Roof
These conditions can lead to: Cement,or TAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin
1.Vapor condensation uniform layer of adhesive less than 1/8 in.(3mm)thick. Excessive
amounts can cause blistering of the shingles and may soften the
2.Buckling of shingles due to deck movement. asphalt in certain underlayments resulting in the asphalt flowing,
3.Rotting of wood members. dripping and staining.Shingles must also be fastened according to
4.Premature failure of roof. the fastening instructions described below.
Correct placement of the fasteners is critical to the performance of
To ensure adequate ventilation and circulation of air,the ventilation the shingle.If the fasteners are not placed as shown in the diagram
system must include inlets and outlets.This may be accomplished and described below,this will result in the termination of TAMKO's
with a combination of ridge and soffit vents or by using gable end liabilities under the Limited Warranty.TAMKO will not be responsible
vents. FHA minimum property standards require one square foot for damage to shingles caused by winds in excess of the applicable
of net free ventilation area to each 150 square feet of space to MPH as stated in the Limited Warranty.See Limited Warranty on the
be vented.This may be reduced to one square foot of ventilation wrapper or tamko.com for details.
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 oena=
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 y,
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1
® (CONTINUED from page 1) FORMERLY HERITAGE®30
ITAMKA HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Tuscaloosa, AL
FASTENING PATTERNS: 4)High Wind Warranty Fastening Pattern.(For High Wind Warranty
1) NAIL ZONE: The Nail Zone for standard fastening is defined as Application requirements) One fastener 1 in. from each end, one
the 1-3/4 in. area beginning at 6-1/8 in. from the bottom edge of fastener total
ofrom each end and one fastener 16 in.from each
f
t
the shingle and ending at the paint line located at 7-7/8 in.from the end fora total 6 fasteners per shingle.In addition to this shingle
bottom edge of the shingle. DO NOT PLACE FASTENERS ON OR fastening patternn requirement for High Wind Application,TAMKO also
ABOVE THE PAINT LINE ON THE SHINGLE. requires the use of TAMKO starter shingles including sealant strip'at
eaves and rakes.Alternatively, along rakes,cement shingles to the
2)Standard Fastening Pattern Options. underlayment and each other in a 4 in.(102 mm)width of TAM-PROD
(For use on decks with slopes 2 in.per foot to 21 in.per foot.) SBS Flashing Cement,TAMKO or TAM-PRO®Plastic Roof Cement,
or TAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin uniform
A. Preferred Fastener Location: Fasteners should be placed 6-1/8 layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts can
in. from the bottom edge of the shingle, penetrating through the cause blistering of the shingles and may soften the asphalt in certain
common bond,and located horizontally as shown in the Standard underlayments resulting In the asphalt flowing,dripping and staining.
Fastening Pattern diagram. High Wind Application is offered on new construction or complete
tear-off applications only.It is not offered for re-cover applications.If
B. Acceptable Fastener Location: Fasteners must be placed in High Wind Application requirements are not followed,the High Wind
the 1-3/4 in.nailing area beginning at 6-1/8 in.from the bottom edge Application Warranty MPH,as stated on Table I in the Limited Warranty,
of the shingle and ending at the paint line located at 7-7/8 in.from reverts to the Standard Application Wind Warranty MPH limit. (See
the bottom edge of the shingle. Nails shall be located horizontally Mansard and High Wind Fastening Pattern illustrated above.)
as shown in the Standard Fastening Pattern diagram. CAUTION: ALL FASTENERS FOR MANSARD AND HIGH WIND
APPLICATIONS MUST BE DRIVEN INTO THE NAIL ZONE
CAUTION: Fasteners must not be driven into the edge of the COMMON BOND(PREFERRED FASTENER LOCATIONS)AS SHOWN
common bond area.Avoid placing fasteners into the sealant strip, IN THE MANSARD AND HIGH WIND FASTENING PATTERN DIAGRAM.
STANDARD FASTENING PATTERN IN NAIL ZONE NAILS:TAMKO recommends the use of nails as the preferred method
of application. Standard type roofing nails should be used. Nail
1 12-1/2"—► —12-3/8"—4� 12-1/2"—.I I -V shanks should be made of minimum 12 gauge wire,and a minimum
PAINT PREFERRED FASTENER LOCATIONS Properly Driven Improperly Driven
LINE Q�3/B°min diameter underdriven overdriven crooked
..... }NAILZONE Asphalt
Shingles .
EDGE OF }
6-1/8" COMMON el �1 Decking
114
BOND !
1/4'nominal
EXPOSURE
5-5/8" straight,good penetration, inadequate too deep,cuts Inadequate
ACCEPTABLE and flush with shingle surface penetration Into shingle anchorage
FASTENER LOCATION
DO NOT FASTEN head diameter of 3/8 in.Nails should be long enough to penetrate
ALONG EDGE OF 3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick,
.................................. COMMON BOND
the nails should be long enough to penetrate completely through
PREFERRED plywood decking and extend at least 1/8 in.through the roof deck.
LOCATION Drive nail head flush with the shingle surface.
STAPLES:If staples are used in the attaching process,follow the
3) Mansard Fastening Pattern. (For use on decks with slopes above instructions for placement.All staples must be driven with
greater than 21 in.per foot.)One fastener 1 in.from each end,one pneumatic staplers.The staple must meet the following minimum
fastener 8-1/2 in.from each end and one fastener 16 in.from each dimensional requirements.Staples must be made from a minimum
end for a total of 6 fasteners per shingle. (See Mansard and High 16 gauge galvanized wire. Crown width must be at least 15/16 in.
Wind Fastening Pattern illustrated below.) (staple crown width is measured outside the legs).Leg length should
be a minimum of 1-1/4 in. for new construction and 1-1/2 in. for
NAILZONE reroofing thus allowing a minimum deck penetration of 3/4 in.The
FASTENERS COMMON crown of the staple must be parallel to the length of the shingle.
BOND The staple crown should be driven flush with the shingle surface.
Staples that are crooked,underdriven or overdriven are considered
8� EXPOSURES-5/8" improperly applied.
Properly Driven Improperly Driven
underdriven overdriven crooked
1-*j Ir7-1/2"►h 7-1I2" 7-38"►h 7-1/2"ih 7-1/2"►I h-1" I ,'. d.l ;
Asphalt
MANSARD AND HIGH WIND WARRANTY Shingles
FASTENING PATTERN Decking
�.mn
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/14.
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2'
® (CONTINUED from page 2) FORMERLY HERITAGE®30
TAMKO HERITRGE8
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Tuscaloosa, AL
4.UNDERLAYMENT S.APPLICATION INSTRUCTIONS
UNDERLAYMENT: An underlayment must be applied over the STARTER COURSE:A startercourse mayconsistof TAMKO Shingle
entire deck before the installation of TAMKO shingles.Failure to add Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self-
underlayment can cause premature failure of the shingles,which is sealing 3-tab shingles are used, remove the exposed tab portion -
not covered by TAMKO's Limited Warranty. and install with the factory applied adhesive adjacent to the eaves.
Products which are acceptable for use as underlayment are: Attach the starter course with approved fasteners along a line parallel
to and 1-1/2 in.to 3 in.above the eaves edge.The starter course
Asphalt Saturated Felt Underlayments: should overhang both the eaves and rake edges 1/4 in.to 3/8 in,if
• SuperX 30TM Underlayment drip edge flashing is not used along the eaves or rakes.If drip edge
flashing is present,install shingles even with the drip edge.
• TAMKO No.15 Asphalt Saturated Organic Felt
For K start wind resistance along rakes,coataflome any
An TAMKO non-perforated asphalt saturated organic felt TAMKO starter shingle Including sealant or cement shingles
• y p p g to uhdo'yment and each other in a m(to2 mm)width of
TAM-PR09 SBS Flashing Cement,TAMKO or TAM-PROS Underlayment Deck
• A non-perforated asphalt saturated organic felt which meets Plastic Roof Cement,or TAMKO Tam-Seal Adhesive. Eave flashing or
ASTM:D226,Type I or II or ASTM D4869 asphan saturated len
Specialty Underlayments:
Drip_.
• Tam-Shield® Synthetic Underlayment or Synthetic Shield edge \...................................................
Underlayment Rake�' _
• TAMKO Moisture Guard Plus®, TW Underlayment or TW Pact—
located1-1010 3
Metal and Tile Underlayment®(additional ventilation may be from rake edge
required.ContactTAMKO's Technical Services Department for J \ Rte\ \
more information.)
Stan Iasi strip with 112 shingle Starter strips overhang Self-sealing Eeve Fasteners Ddpedga.
• A self-adhesive underlayment designed for use with asphalt rhipsin.dert000setwith hl° eaves and adhesive °entad
Y 9 P
strips in order f flow with the eav s nd rakes tldp edge positioned 1-12'to 3-
shingles which meets ASTM D1970.
first shingle course. flashing is present.If drip along eaves from save edge
edge flashing ispmeoni, or rake edge
install shingles even with
For Asphalt Saturated Felt Underlayments: drip edge.
Apply the felt when the deck is dry.On roof decks with slopes SHINGLE APPLICATION: Start the first course with a full-si.ze
4 in. per foot and greater apply the felt parallel to the eaves shingle and overhang the rake edge 1/4 in.if drip edge is not present..
lapping each course of the felt over the lower course at least If drip edge is present, align shingle edge with drip edge flashing.
2 in.Where ends join,lap the felt 4 in.If left exposed,the felt Cut 10-3/8 in.from a full shingle to form a shingle 29 in.long.Use
may be adversely affected by moisture and weathering.Laying this to start the second course(see diagram below). Cut a 23 in.
of the felt and the shingle application must be done together. long shingle to start the third course.Use the remaining 16-3/8 in.
For All Other Specialty Underlayments: piece of shingle to start the fourth course and use the remaining
10-3/8 in,piece to begin the fifth course.Continue up the rake in as
On roof decks with slopes 4 in. per foot and greater, apply many rows as necessary using the same formula as outlined above.
the underlayment parallel to the eaves in accordance
with underlayment application written instructions. The
underlayment should not be left exposed for a longer period of 10-3/8"
time than is specified in the underlayment application written
instructions.The final roof covering must be installed before
repeat 10-3/8"
the structure is exposed to adverse weather conditions,such courses 16-3/8" 29"
as wind driven rain,high wind,hail,ice storms etc.
In areas where ice builds up along the eaves or a back-up of water ,
from frozen or clogged gutters is a potential problem, TAMKO 29
16-3/8: 23'"
Moisture Guard Plus®, TW Metal and Tile Underlayment or TW rakes"�I
Underlayment (or any specialty eaves flashing product) may be 10-3/8"
applied to eaves,rakes,ridges,valleys,around chimneys,skylights
or dormers to help prevent water damage. Contact TAMKO's 5th cc
Drse
Technical Services Department for more informations 3/a" 23" 16 318 ti
4th course
Substitute products as shingle underlayment should not be used. 3rd course " 23"
2nd course - 29 a _ ^"29"-
1stcourse L- F 1I 10L3/8"
�save�
I .
i
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 l 09/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3'
k
P,
o (CONTINUED from page 3) FORMERLY HERITAGE®30'
jTA:1KO0 HERITAGE®
BUHMING PRODUCTS 6AMINATED ASPHALT SHING6ES
Tuscaloosa, AL
The butt of the shingle should be aligned with the top edge of the multi-layered shingles.The performance of the sealant feature may
sawtooth of the underlying shingle for a 5-5/8 in. exposure (see be compromised, preventing the shingles from sealing properly. It is
shingle application drawing illustrated on this panel). When you acceptable to install laminated shingles over existing three-tab strip
make your final cut at the roof's edge,flip any pieces that are 8 in.or shingles which are flat and essentially intact.Nail down or remove curled
longer back onto the roof.These pieces can be worked in anywhere or broken shingles from the existing roof.Replace all missing shingles
without creating zippers or color variations. with new ones to provide a smooth base.Shingles that are buckled
NOTE:Do not align joints of shingle courses when working in cut usually indicate warped decking or protruding nails.Hammer down all
pieces.Joints should be no closer than 4 in.from one another. protruding nails or remove them and refasten in a new location.Re'mpvg
all drip edge metal and replace with new.
1Cut your first course shingle to make 29'and a ID 3/8" If reroofingover an existing roof where new flashing is required to protect
.length.Cut a second shingle to make a 23'and 9 9 Q
a 16 3/8'length. '� against ice dams(freeze/thaw cycle of water and/or the backup of water
in frozen or clogged gutters),remove the old roofing to a point at least
24 in.beyond the interior wall line and apply TAMKO Moisture Guard
Plus®,TW Metal and Tile Underlayment,or TW Underlayment.Contact
TAMKO's Technical Services Department for more information.
Measurements will vary when nesting over an existing 5 in.exposure
single roof:Call TAMKO Technical Services for further information.
The nesting procedure described below is the preferred method for.
reroofing over existing metric size shingles with a 5-5/8 in.exposure.
See description below:
,2eeginayyou,29',2',6lllengtd1031W Starter Course:Remove the tabs and an additional portion from the
Then layyour28'.23",16 3/8'gth hi3/8'Ienglhs.
As you can see.three shingles with two cuts head of a full-size shingle so that its height is equal to the exposure of
make live coursa:. the existing shingles.Position the resulting strip over the existing roof
continue work ng edge with the factory-applied adhesive stri along the eaves. Cut
g your way across the root When you make your 9 ( P 9 - ,.
3.final cul at the roofs edge,flip any pieces that are 8'or longer approximately 6 in.from the rake end and apply the remaining portion at
back onto the roof.These pieces can be worked in anywhere without
creating zippers or color varlrtiuns. the eaves.Continue the starter strip by applying full length shingle strip"s
NOTE:Do not align taints of shingle courses when working In
cat places.Joints should be no closer than V from one aaother. cut to height as above,evenly along the existing roof at the eaves.Thte
existing roof should overhang the eaves far enough to carry water
6.LOW SLOPE APPLICATION off into the gutter.If this is not the case,cut and apply the start04
On pitches 2 in. per foot to 4 in.per foot cover the deck with two strip so that it will provide sufficient overhang for proper drainage:
layers of underlayment. Begin by applying the underlayment in a First Course:Remove anamountfromthe buttedgeofafull-sizeshingle
1/2-sheet width along the eaves and overhanging the drip edge so that the remaining portion of the shingle fits between the butts of the
by 1/4 to 3/4 in. Place a full-sheet width over the 1/2-sheet width existing third course.This course must also be applied evenly along the
starter piece,completely overlapping it.All succeeding courses will eaves edge of the new starter strip.
be positioned to overlap the preceding course by 1/2-sheet width.
If winter temperatures average 25oF or less, thoroughly cement Existing shingles
the laps of the entire underlayment to each other with TAM-PRO
or TAMKO Plastic Roof Cement from eaves and rakes to a point 55/8°
of a least 24 in, inside the interior wall line of the building. As 131/4" t
an alternative, TAMKO Moisture Guard Plus®, TW Metal and Tile /4e
Underlayment, or TW Underlayment self-adhering underlayment
may be used in lieu of the cemented felts.
Drip edge
7.MANSARD ROOF OR STEEP SLOPE ROOF Drip edge
If the slope exceeds 21 in.per foot(60),each shingle must be sealed New shingles
with TAM-PRO@ SBS Flashing Cement, TAMKO or TAM-PROD
Plastic Roof Cement, or TAMKO Tam-Seal Adhesive immediately 55"" 35/8°exposure
upon installation.Quarter-sized dabs of cement must be applied to exposure
shingles with a 5-5/8 in.exposure,use 6 fasteners per shingle.See
Section 3 for the Mansard Fastening Pattern.
Second and Succeeding Courses:Remove 10-3/8 in.from the;rgke
8.REROOFING end of the first shingle in the second course, and continue with full
width shingles for the remainder of the course,placing the top edge,of
Before reroofing,be certain to inspect the roof decks.All plywood shall each new shingle against the butt edge of the old shingle in the courge
meet the requirements listed in Section 1. above.This method should create an exposure of 5-5/8 in.after the first
It is not recommended to install laminated asphalt shingles directly course.When beginning the succeeding courses continue to follow�the
over existing laminated shingles due to the unevenness of the existing Heritage application instructions.(See section 5). 1
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/14;
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 g
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4
® (CONTINUED from page 4)
FORMERLY HERITA97,EO;30
TAMKO HERITAGE®
BUILDING PRODUCTS LANINATBD ASPHALT SHINGLES g;
Tuscaloosa, AL
I
9.VA166EY APP61CATION 10. HIP AND RIDGE FASTENING DETAIL
Over the shingle underlayment,center a minimum 36 in.wide sheet Apply the shingles with a 5-1/8 in.exposure beginning at the bottom
of TAMKO Moisture Guard Plus®,TW Metal&Tile Underlayment, of the hip or from the end of the ridge opposite the direction of the
or a minimum 50 Ib.roll roofing in the valley.Nail the underlayment prevailing winds.Secure each shingle with one fastener on each side,
only where necessary to hold it in place and then only nail the 5-5/8 in.back from the exposed end and 1 in.up from the edge.
outside edges, TAMKO recommends the use of TAMKO Hip & Ridge shingle
IMPORTANT.PRIOR TO INSTALLATION,WARM SHINGLES TO products.Where matching colors are available,it is acceptable•to
PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING use TAMKO Elite Glass-Seal shingles cut down to 12 in.pieces.
SHINGLES TO FORM VALLEY. The length of the fastener should be long enough to penetrate
After valley flashing is in place: through the roofing material and 3/4 in. into the wood decking-or
• Apply the first course of shingles along the eaves of one of the completely through approved plywood.
intersecting roof planes and across the valley. IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS TO BE
Note:For properflowofwateroverthetrimmedshingle,alwa s TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE`rl
start applying the shingles on the roof plane that has the lower BENDING SHINGLES IN COLD WEATHER. Y'
slope or less height. Direction of prevailing wind
• Extend the end shingle at least 12 in.onto the adjoining roof. Start 5-1/8"exposure
Apply succeeding courses in the same manner,extending them here— H
across the valley and onto the adjoining roof.
Fastener
• Press the shingles tightly into the valley. l 11r'5-1/8°
• Use normal.shingle fastening methods. III here
5-1/8"exposure
Note:No fastener should be within 6 in.of the valley centerline,
and two fasteners should be placed at the end of each shingle THESE ARE THE MANUFACTURER'S APPLICATION
crossing the valley. INSTRUCTIONS FOR THE ROOFING CONDITIONS
• To the adjoining roof plane,apply one row of shingles vertically DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES
facing the valley and 2 in.back from the valley centerline. NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
Note: For a neater installation, snap a chalkline over the MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW
shingles for guidance. THESE INSTRUCTIONS WILL ADVERSELYAFFECT COVERAGE
• To complete the valley, apply shingles on the adjoining roof UNDER THE LIMITED WARRANTY. SEE THE LIMITED
plane by positioning the tip of the first shingle of each row at WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS
the 2 in.point from the centerline where the edge of the vertical REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE
shingle has been applied,covering the vertical shingle. CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT'AT
800-641-4691.
Valley centerline
Minimum 36'wide sheet -
of Nail Fast,Moisture
Guard Plus or 50 Ib. Extra nail in Information included in these application instructions was current at time of printing•
or heavier roll roofing end of shingle To obtain a copy of the most current version of these application instructions,visit us o'nlin'e
Extend end shingle at tamko.com or call us at 800-641-4691.
12'-18'beyond
valley centerline TAMKO@,Moisture Guard Plus@,Tam-Shield@,TAM-PRO@ and Heritage@ are registered
trademarks and SuperX 30 is a trademark of TAMKO Building Products,Inc.
Underlayment No fasteners within
6'of centerline
Place tip of shingle on the edge of
the vertical shingle,2 inches back
from valley centerline and covering
the vertical shingle. _
FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
800-641-4691.
a
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 osn4:�
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 ,1
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5;
JP69907"
6/30/2015 Florida Building Code Online
of k t� x
Rodda Departments BCIS Home Log In User Registration Hot Topics submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map I Links Search
Business/P)
Product A
Professibn)l oii USER: PubliccUU eroval
Regulation
Product Approval Menu>Product or Aoolication Search>Application List>Application Detail
FL# FL2569-R9
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu.
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON-US 00000
(819)478-2400 Ext 3327 rr•.,
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
1 Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Robert J. M. Nieminen
the Evaluation Report
Florida License PE-59166
e:
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R9 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6163 2000
ASTM D6164 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
https://floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xYIX2%2f`/o2bLT9pl88%3d 1/2
6/30/2015 Florida Building Code Online
TAS 110 2000
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/17/2015
Date Validated 04/21/2015
Date Pending FBC Approval 04/25/2015
Date Approved 06/23/2015
Date Revised 06/29/2015
Summary of Products
...
FL# i Model,Number or Name Description
2569.1 !Soprema Roof Self adhering roof underlayments
Underlayments I
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL2569 R9 II 2015 04 FINAL ER SOPREMA CA UNDERLAYMENTS FL?_569-
Approved for use outside HVHZ:Yes R9,Ddf
Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-90 Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of Evaluation Reports
Use. 2.)The design pressure noted herein FL2569 R9 AE 2015 04 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
pertains to underlayment systems used R9.Ddf
beneath adhesive-set tile systems. Refer to Created by Independent Third Party: Yes ——
ER Section 5.6.4 for details.
FENext
Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone: 850-487-1824 `
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refund Statement:'
Under Florida law,email addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dick here.
Product Approval Accepts:
S.- eCtesi:
securill•m z:iiyI./tics
https://floridabuilding.org/pr/pr_ppp_ d.aspx?param=wGEVXQwtDgsKQFEnckBl08ErxlUd3xYIX2%2f%2bLT9pl88%3d 2/2
�~ , \ EXTERIOR RESEARCH&DESIGN, LLC.
t - Certificate of Authorization#9503
J ® 353 CHRISTIAN STREET,UNIT#.13
```.,�# T INITY ERR OXFORD, CT 06478
PHONE:(203)262-9245 ..,
FAX:(203)262-9243
EVALUATION REPORT
Soprema, Inc. Evaluation Report S18010.06.09-R7
1640 rue Haggerty 171-2569-139
Drummondville, Quebec J2C 5138 Date of Issuance:06/15/2009
Canada Revision 7:04/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the reference
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
N1t�)tgf�pry,
t$.
Robert J.M. Nieminen P.E. %J•.-p .. T,:.'; The facsimile seal appearing was authorized by RobertNieminen,�,l_;
° %r'hF.S�;C �.•�.:`�.`' P.E.on 04/17/2015.This does not serve as an electronically signed.
Florida Registration No.59166,Florida DCA ANE1983 h�tON>L�'`}^ document.Signed,sealed hardcopies have been transmitted to tht
`� Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE: ¢r,
1, TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
j ' I
el—�1
..��TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
i
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following
sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004 :t
1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TA5 110 2000
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Knfty Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-131 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Physical Properties/Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering,non-woven polyester fabric surfaced,SBS modified bitumen roof underlayment.
4.2 Lastobond Shield is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available
in two widths;36 and 45 inch.
4.3 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.4 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch.
4.5 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.6 Lastobond 195 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.7 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.8 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R7
Certificate of Authorization#9503 FL2569-R9
Revision 7:04/17/2015
Page 2 of 6
4.9 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof
underlayment.
4.10 Resisto LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with
a 36-inch sheet width.
4.11 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified
bitumen roof underlayment,with a 36-inch sheet width.
4.12 Resisto LB1244 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with
a 44-inch sheet width.
4.13 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment.
4.14 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate
Shingles Shingles
Lastobond TU HT Yes Yes Yes See 5.5.1 Yes Yes Yes
Lastobond Shield/Pro HT-N Yes No No No Yes Yes
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Lastobond ECO /Resisto LB1236,
Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes
Resisto LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes'.
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1 a.4;
Unilay(e) Yes Yes Yes No No No.,
Batten Only See 5.5.1
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion /long term aging data from an
accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond'"Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
i
• i
i
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R7
Certificate of Authorization#9503 FL2569-99,
Revision 7:04/17/2015;
Page 3 of,6,
'� i
' T61�11 ER®
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT or Lastobond Pro HT-S applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, Resisto LB1236, Grip-Rite Eave & Valley Protector,
Resisto LB1244 or Lastobond Smooth Seal HT applied to:
Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
Y Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with
Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond Pro HT-S or Colphene FR
GR applied to:
➢ DensDeck DuraGuard;DensDeck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT,Lastobond Pro HT-S or Colphene FR GR applied to: f-
➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimurri
codified requirements. For installations under foam-on tile systems,base layer shall be attached in accordance.with
FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure'is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c,at the 4-inch laps and 6-inch o.c.in three,equally spaced rows in,the
center of the sheet.
Underlayment: Colphene FR GR,self-adhered
i
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R7
Certificate of Authorization#9503 FL2569=119
Revision 7:04/17/2015
Page 4 of 6
TRINITY!ER®
5.6.4.4 Maximum Design Pressure=-90.0 Psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e)mechanically attached with Soprafix Polymer Batten Bar(PBB)or Soprafix Metal Batten
Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. within the 5-inch wide, self-
adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air
welding techniques,
5.7 Exposure Limitations:
5.7.1 Lastobond Shield,Lastobond Pro HT-N,Lastobond,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Resisto
LB1236, Grip-Rite Eave &Valley Protector or Resisto LB1244 shall not be left exposed for longer than 30-days after
installation.
5.7.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation.
5.7.3 Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-days after installation:
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick or Elastocol 600c(if applicable).
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond,
Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Resisto LB1236, Grip-Rite Eave & Valley Protector,
Resisto LB1244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the
type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover
is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release
film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches,.configured to shed water. Vertical seams should be 6-inches.6nd
staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using
either heat-welding or hot air welding techniques.
When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet
at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge.Drape and press sheet into place,working from the center of the valley or ridge in each direction. For
valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12)_Installation Manual and Table 1 herein, using the instructions
noted above as a guideline,
For Colphene FR GR in foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance
limitations,
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-R7
Certificate of Authorization#9503 FL25691RS
Revision 7:04/17/2015
Page 5 of 6
�.� TRINITY i ERD
6_4 Unila e :
6.4.1 Non-Tile Applications or Nail-On.Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if applicable).
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attdcr
the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-nails spaced 36-inch o.c. Apply
the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over=
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile (if applicable) shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
6.4.2 Foam-On Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein.
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope, mechanically attach
the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar (PBB) or Soprafix Metal Batten Bar
(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c. Apply the second course in a water-shedding manner with
self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a
watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS: y: i
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
END OF EVALUATION REPORT-
.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R7
Certificate of Authorization 119503 FL2569-119
Revision 7:04/17/2015
Page 6 of 6
9/24/2015 Florida Building Code Online
,. lr�
J�Ijd�G`2paRi11°ntq BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search
Busines N)�
Professin'al °d"°tapp'°"a'
USER: Public User
Regulation
Product ADDroval Menu>Product or ADDIIcation Search>Application Lis[>Application Detail
+iS`t"a"`•"T' "t"�-' FL# FL10758-R6
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville,OH 43023
(740) 321-6345
greg.keeler@owenscorning.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity Miami-Dade BCCO-QUA
Quality Assurance Contract Expiration Date 04/13/2018
Validated By Locke Bowden
V Validation Checklist-Hardcopy Received
Certificate of Independence FL10758 R6 COI OCR14003.2 2014 FBC nonHVHZ Evaluation Reoort
Owens Corning Vents 060514.Ddf
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1709.2
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvl dAvlteOYOD/o2bC3zFtrydg9ubWM rxzLHkvl rEPVYDH 9EQp/o3d°/D3d 1/2
9/24/2015 Florida Building Code Online
Product Approval Method Method 2 Option B
Date Submitted 02/23/2015
Date Validated 02/24/2015
Date Pending FBC Approval 03/01/2015
Date Approved 04/15/2015
Summary of Products
FL# — Model,Number or Name Description
10758.1 VentSure 4-Foot Strip Heat and Copolymer plastic low profile attic ridge vents for installation
Moisture Ridge Vents in shingle roof systems
---- —— -- ----
.............._....---
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10758 R6 II OCR14003.2 2014 FBC nonHVHZ Evaluation
Approved for use outside HVHZ:Yes Report Owens Corning Vents 060514.Odf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to evaluation report Evaluation Reports
FL10758 R6 AE OCR14003.2 2014 FBC nonHVHZ Evaluation
Report Owens Corning Vents 060514.pdf
Created by Independent Third Party: Yes
10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent
Roof Vent With Exterior Louver
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10758 R6 II OCR14003.2 2014 FBC nonHVHZ Evaluation
Approved for use outside HVHZ:Yes Report Owens Corning Vents 060514.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to evaluation report. Evaluation Reports
FL10758 R6 AE OCR14003.2 2014 FBC nonHVHZ Evaluation
Report Owens Corning Vents 060514.pdf
Created by Independent Third Party: Yes
10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10758 R6 II OCR14003.2 2014 FBC nonHVHZ Evaluation
Approved for use outside HVHZ:Yes Report Owens Corning Vents 060514.odf
Impact Resistant: N/A Verified By:.Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to evaluation report. Evaluation Reports
FL10758 R6 AE OCR14003.2 2014 FBC nonHVHZ Evaluation
ReDort Owens Corning Vents 060514.pdf
Created by Independent Third Party: Yes
f5ack NC�t
Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
sccuritymi ir.R.s
https://floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgvldAviteOY0%2bC3zFtrydg9ubWMrxzLHkvlrEPVYDH9EQp/`3d%3d 212
Certificate of Authorization No. 29824
K17520 Edinburgh Dr R1
F Tampa, FL33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued February 23, 2015
1 Owens Corning Parkway
Toledo,OH 43657
(800)438-7465
www.owenscorning.com
Manufacturing Plants: Rohnert Park, CA;Orrick, MO; Baldwyn, MS; Niles, OH
Quality Assurance: Miami-Dade BCCO—QUA(QUA1591)
SCOPE
Category: Roofing
Subcategory: Roofing Accessories that are an Integral Part of the Roofing System
Code Sections: 1709.2
Properties: Roof Ventilation
REFERENCES
Entity Report No. Standard Year
Architectural Testing,Inc(TST1558) 01-38660.04 TAS 100(A) 1995
Architectural Testing,Inc(TST1558) 01-38660.05 TAS 100(A) 1995
Architectural Testing,Inc(TST1558) C1774.01-109-18 TAS 100(A) 1995
ASTM D 635 2006
ASTM D 1929 2001 e01
ASTM D 2843 2004e01
PRI Construction Materials Technologies(TST5878) AVIG-005-02-01 ASTM D 635 2006
ASTM D 1929 2001 e01
ASTM D 2843 2004e01
PRI Construction Materials Technologies(TST5878) AVIG-006-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) OCF-111-02-01 ASTM D 635 2006
ASTM D 1929 2001e01
ASTM D 2843 2004e01
PRI Construction Materials Technologies(TST5878) OCF-112-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) OCF-116-02-01 TAS 110(A) 1995
PRI Construction Materials Technologies(TST5878) OCF-223-02-01 TAS 110(A) 1995
PRI Construction Materials Technologies(TST5878) OHI-007-02-01 TAS 100(A) 1995
PRODUCT DESCRIPTION AND APPLICATION
VentSure"4-Foot Strip 1-1/4" x 14-7/8" x 48" low-profile attic ridge vent consisting of a two-layer nylon-
Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for
Vents: installation in shingle roof systems.
48"
14-7/8"
a
OCR14003.2 FL10758-R6 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid'.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
• OWENS CORNING ROOFING AND ASPHALT LLC
'to MOLO`� I
VentSure®Roof Ventilation
f` E w m E, K
'TECHNICAL SERVICES, LLC
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12 to maximum 16/12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 6-inches from the rake
edges. Apply a '/4-inch wide bead of ASTM D 4586 roofing cement along the entire
length of the outside edges of the vent to seal the vent to the field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga. 2'h-inch galvanized ring shank nails
(shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be
installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each
vent piece.
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten to the deck in the same manner as the first
section. Fasten the ridge shingles over the vent to the deck on the marked "shingle
nail line" with two (2) minimum 11 ga. 2%-inch galvanized ring shank roofing nails
(shall comply with FBC Section 1506.5) prvided with the vent or as directed by the
shingle manufacturer's installation instructions. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
VentSure'Low Profile 18"x 24"x 2-3/16"(32"x 23"flange base)static off-ridge vent composed of ASTM
Slant Back Roof Vent A653 galvanized steel (available with painted finish): Material shall conform with
with Exterior Louver: FBC Section 1507.4.3.
i
i
---1--
,p
.T ,__ �r�-
FRorr
BACK
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
OCR14003.2 FL10758-R6 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
• OWENS CORNING ROOFING AND ASPHALT LLC
VentSure Roof Ventilation
CRAEA JEoK
TECHNICAL SERVICES, LLC
Roof slope: Minimum 3:12
Installation Height: Maximum 33-ft
Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from
the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement
around inner and outer flange. Place vent directly over the hole, ensuring the vent
sits flat on the roof. Fasten vent 4-inches o.c.and 1-inch from outside edge of flange
with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per
vent).
Install baffle in %4-inch bed of ASTM D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5)
spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through
wood deck. Seal all.nails and vent flange with ASTM D 4586 roofing cement.
Allowable Roof Coverings: Asphalt shingles
VentSure'Rigid Roll 5/8"x 11-1/4"x 20'attic ridge vent composed of high density polypropylene with a
Ridge Vent: spun-bond polypropylene fabric.
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 12-inches from the rake
edges. Apply a continuous bead of polyurethane adhesive sealant along the entire
length of the outside edges of the vent to seal the vent to the field shingles. Center
the vent over the opening and fasten the vent 24-inches o.c. to the deck using
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5),
ensuring%-inch penetration through wood deck.
Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line"
with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5) or as directed by the shingle manufacturer's installation instructions,
ensuring%-inch penetration through wood deck. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
OCR14003.2 FL10758-R6 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
{
OWENS CORNING ROOFING AND ASPHALT LLC
VentSure®Roof Ventilation
CREEI
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is outside the scope of this evaluation.
2) This report is not for use in the HVHZ.
3) The roof deck and deck attachment shall be designed by others in accordance with the 2014 FBC.
4) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
5) Owens Corning vents shall be installed in strict compliance with this evaluation report and the
manufacturer's published installation instructions. In the event of conflict, the more restrictive installation
shall be enforced.
6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion prior to installation.
7) Installation of the roof assembly is outside the scope of this evaluation.
8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
�iiirrrrr
%%% ��� 2015.02.2
%�� RY R
, p
`,,��.••.�,cErvs� .•sem.,, �� 3 14:48:59
c F
No N 74021
� s
*' '* = -05'00'
O'. STATE OF : UJ
"C". c,� Q P.�N --�` Zachary R. Priest, P.E.
'i�s'•• R t. C?�1` Florida Registration No.74021
,SJONA,E�%N, Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14003.2 FL10758-R6 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.