Loading...
HomeMy WebLinkAboutDrawing 1 2 62" X 80" 36" X 80" FIL EPLACE DOORS IN 2 OPENINGS ONLY. MAR O 9 201 'I' E COP NEW DOORS TO BE IMPACT RESISTANT- HURRICANE SHUTTERS NOT REQUIRED. PERMITTING St. Lucie County, FL OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 62 80 34.44 5 35.1 -45.2 FL16647.4 50.0 1 -50.0 BEDROOM-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 13 FT 3 IN ODOM RESIDENCE 3700 MENENDEZ AVENUE DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA