HomeMy WebLinkAboutDrawing 1 2
62" X 80" 36" X 80"
FIL
EPLACE DOORS IN 2 OPENINGS ONLY. MAR O 9 201
'I' E COP NEW DOORS TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED. PERMITTING
St. Lucie County, FL
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 62 80 34.44 5 35.1 -45.2 FL16647.4 50.0 1 -50.0 BEDROOM-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 13 FT 3 IN
ODOM RESIDENCE
3700 MENENDEZ AVENUE DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA