Loading...
HomeMy WebLinkAboutProduct Approval A MIAMI-QADE MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 01,11 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamiaade.aov/economy GAF 1 Campus Drive Parsippany,NJ 07054 FILE - L;01Jy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Royal Sovereign®Shingle LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 12-1127.03 and consists of pages 1 through 4. The submitted documentation was reviewed by Juan E. Collao,R.A. NOA No.: 14-1022.16 MIAMI•oADE COUNTY Expiration Date:04/22/18 Approval Date:02/05/15 Page 1 of 4 ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Category: Asphalt Shingles Materials 3-Tab Deck Type: Wood SCOPE This approves GAF Royal Sovereign®Shingle as manufactured by GAF as described in this Notice of Acceptance, designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Royal Sovereign®Shingle 12" x 36" TAS 110 Fiberglas reinforced heavy weight asphalt roof shingle,with a 3-Tab profile MANUFACTURING LOCATIONS 1. Savannah, GA. 2. Tuscaloosa,AL. 3. Tampa,FL. 4. Mt.Vernon,IN. 5. Mobile,AL. 6. Dallas,TX. 7. Myerstown,PA. 8. Fontana,CA. 9. Minneapolis,MN. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering TAS 100 02/23/94 ASTM D3462 257966 03/21/97 PRI Asphalt Technologies,Inc. TAS 100 GAF-105-02-01 11/14/05 TAS 100 GAF-182-02-01 02/07/08 PRI Construction Materials Technologies,Inc. TAS 100 GAF-332-02-01 01/17/12 TAS 100 GAF-376-02-01 10/15/12 TAS 100 GAF-153-02-01 11/30/06 Underwriters Laboratories,Inc. TAS 107 05CA48258 11/28/05 TAS 107 05CA47804 11/11/05 TAS 107 08NK02337 03/12/08 TAS 107 08NK12906 10/10/08 TAS 107 11 CA47919 12/03/11 ASTM D 3161 /TAS 107 09CA41642 09/28/10 ASTM D 3161 /TAS 107 09CA38549 10/30/09 NOA No.: 14-1022.16 r71 t•DAnecouwrir Expiration Date: 04/22/18 Approval Date:02/05/15 Page 2 of 4 EVIDENCE SUBMITTED(CONTINUED) Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,Inc. ASTM D 3462 ASTM D3462 09/12/06 ASTM D 3462 08NK02337 03/12/08 ASTM D 3462 09CA21715 05/20/09 ASTM D 3462 08CA61515 07/15/09 ASTM D 3462 11CA47919 12/03/11 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Applications Standard RAS 115. 2. Flashing shall be in accordance with Roofing Applications Standard RAS 115. 3. The manufacturer shall provide clearly written application instruction. 4. Exposure and course layout shall be in compliance with Detail"A",attached. 5. Nailing shall be in compliance with Detail`B",attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility,and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Oficial or the applicable code in.order to properly evaluate the installation of this system. NOA No.: 14-1022.16 MIAMI•DAD,COUNTY Expiration Date:04/22/18 Approval Date:02/05/15 Page 3 of 4 DETAIL A COURSE LAYOUT 1 st Course of Shingles 2nd Course of Shingles 3rd Course of Shingles Moo 6" 5. • Drip Edge DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 36" X LO LO END OF THIS ACCEPTANCE NOA No.:14-1022.16 Mlar�I•aane couw7�r Expiration Date:04/22/18 Approval Date:02/05/15 Page 4 of 4