HomeMy WebLinkAboutDrawingRE
NI
HI
36" X 80"
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO'OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 11 FT 6 IN
BROWNE RESIDENCE
11180 ORANGE AVENUE
FORT PIERCE, FLORIDA
DOOR REPLACEMENT PLAN
OPENING
PRODUCT
DESIGN
OPENING
SQ.
WIND
PRESSURES
APPROVAL
I
PRESSURES COMMENTS
I
NO. WDTH. HGT.
FTG.
ZONE
POS. NEG.
(N.O.A. #)
POS. NEG.
1 1 36 80
20.00
1 4
1 36.1 1 -39.3
1 FL16674.1
1 50.0 1 -50.0 FRONT ENTRY - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO'OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 11 FT 6 IN
BROWNE RESIDENCE
11180 ORANGE AVENUE
FORT PIERCE, FLORIDA
DOOR REPLACEMENT PLAN