i'71 r g, PER?41ITTirgG
( nx FL# FL12425-R7 St. Lucie l;ot;nty, r t_
. a� N
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived F-i
Product Manufacturer JELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls,OR 97601
(800) 535-3936
fbcl@jeld-wen.com
Authorized Signature Kaede McLaughlin
fbcl@jeld-wen.com
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls,OR 97601
(800) 535-3936
customerserviceagents@jeld-wen.com
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sliding Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency American Architectural Manufacturers Association
Validated By American Architectural Manufacturers Association
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2008
Equivalence of Product Standards
Certified By
https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsjlXgYDJMD2eyK2hHWFL2kpOOV8iLZ2iZZ7gpsRfl3XA%3d%3d Page 1 of 2
Y �
Florida Building Code Online 3/14/17,10:39 PM
Product Approval Method Method 1 Option A
Date Submitted 06/24/2016
Date Validated 07/13/2016
Date Pending FBC Approval
Date Approved 07/17/2016
Summary of Products
FL# Model, Number or Name Description
12425.1 Premium Vinyl (V-4500) Sliding Patio Door(XO or OX) 71 1/2"x 79 1/2"Insulated Glass (1/8 in
-1/8 out Tempered) (Safety Glazing)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL12425 R7 C_CAC_XO R-PG50-71.5x79.5 New.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date €
Impact Resistant: No 09/26/2021
Design Pressure: +50/-50 Installation Instructions
Other: FL12425 R7 II 71.5x79.5_Installation.pdf
Verified By: American Architectural Manufacturers Association
Created by Independent Third Party: j
Evaluation Reports !
L1242 _R7_AF_PER3037.pd j
Created by Independent Third Party: Yes
i
12425.2 Premium Vinyl (V-4500) Sliding Patio Door(XO or OX)96"x 96"Insulated Glass(1/8 in-1/8 out
Tempered) (Safety Glazing)
Limits of Use Certification Agency Certificate i
Approved for use in HVHZ: No FL12425_R7_C_CAC_XO LC-PG35-96x96_Certificate.pdf
i
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date j
Impact Resistant: No 08/12/2017
Design Pressure: +35/-35 Installation Instructions
Other: FL12425 R7 U_PG35 Slidina_Patio Door Installation Instructions.pdf
Verified By: Hermes F. Norero, P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL12425 R7
_AE PER3038.pd
Created by Independent Third Party: Yes
t3ac€c SVext
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here_'.
Product Approval Accepts:
f ® RE
Credit Card
Safe.
y, 1 ,el
https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsjlXgYDJMD2eyK2hHWFL2kpOOV8iLZ2iZZ7gpsRfl3XA%3d%3d Page 2 of 2
�I
..............................._......................_._.__..................._......_........_......._........................................................................................................................................................................._.
4" � � NAIL FIN INSTALLATION
8'O.C. MAX. FROM 11/z^MIN.EMBEDMENT
WAX
RU NAIL nN-h-�-I-CORNERS
3
2 _..............................._.._.. ............_.................
2x WOOD FRAME .....__.._..._.............................i
a'D.Q. MIN.DISTANCE
MAX. THRU FOR EDGE 3/4"
NAIL FIN MIN.DISTANCE
I
FOR EDGE:3/4"
SHIM APACE SHI MAX
M SPACE
3 SHI
i 2x WOOD po !
FRAME +
3 mm 11/2 MIN. a
aamm EMBEDMENT
I 1 �
1
1- G 13A BITE
� 0
S 1
C i
Qg i
. � 'GLAZINGDETAL. �0—
FRAME SECTION(TYP) TYP JAMB SECTION VERTICAL SECTION ( )
HORIZONTAL SECTION
NOTE:Ccuik Ce!wem NrJllV FI"rge 6 Wend Opening.
I
U4"MAX
SHIM SPACE
MIN,DISTANCE I
DOFORFR
/4'i 2.WOOD FRAME Max Frame OP RATING IMPACT
OR WIDTH (-11.s' MAS.} I 1 2 3 AM71.5 x79.5 +50/-50 1 NO
TYPICAL ELEVATION WITH FASTENER SPACING is z^MIN.EMBEDMENT
Installation Notes: General Notes:
1., Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of
2. Use#8 PH or greater fastener.through the nail fin with sufficient length to penetrate a minimum of 1 the adopted International Building Code(IBC),the international Residential Cade(IRC),the Florida
112"into the wood framing. For 2x wood frame substrate(min.S.G.=0.42) Building Code(FBC)and the.industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored.to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3.1mm tempered-13.Omm airspace-3.1mm tempered glass.
project of installation. 4. Use structural or composite shims where required.
5. Installation methods can be interchanged within the same opening.
6. An impact protective system is required where wind bome debris protection is mandated by local
Digitally signed by Hermes F.Norero,P.E. building Code.
This schedule addresses only the fasteners required to anchor the Reason:I am approv�ep�t�I document
Date:2o14.os. 1, ll ,�d'%ey 7. Maximum sizes are buck sizes and do not include fin or flange.
At window to achieve the rated design pressure up to the size limitations �� i10�
t.
noted. It,is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE;
i _ 3737 Lakeport Blvd
not address he sealing consideration that may arise in differentwall ��� �c" '�•• " �` �� - . 07/16/2Q14
• :'••• JIMRWEN Klamath Falls,OR:97601
conditions. For the complete installation procedures see the instructionsDRAwN av: scaLE:
D.Vezo NTS Phone: (541)882-3451
packaged with the window or go to 7 �.-- `CHECKED sr: TITLE:
www.jeld-wen.com/resources/installation. = 7E 7k _ J. Kantola
DISCLAIMER: " `PCI
° APPROVED BY: Premium Vinyl Sliding Patio Door
This drawingand its contents are confidential and are not to be %`PQ •••. OP'••� ��, �� RT P 0 ECT o
reproduced or copied in whole or in part or used or disclosed to others ��i� �,: ;rierO �;'`� P60 446
except as authorized b JELD-WEN Inc. sea 1 �Ij�SE 938 1DENTIFI No. PLANT NAME AND LOCATION: CAD DWG:No.: REV: SHEETp y SJW2012-204-F C 00 SDF4