HomeMy WebLinkAboutProduct Approval (4) Flororrid Building Code Online 3/14/17,10:12 PM
1211=n
�1 BCIS Home i Log In User Registration i Hot Topics Submit Surcharge Stats&Facts j Publications FBC Staff BCIS Site Map Links I Search
1 o
,. Product Approval
USER:Public User ` �;�+
�ge'.. P , . �Z
�� ;
Product Approval Menu>Product or Application Search>Application List>Application Detail
MAR I a 201
` FL# FL17676-R3 ���131�1i�
Application Type Revision M
Code Version 2014 St. Lucie County, FL
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer MI Windows and Doors
Address/Phone/Email 650 West Market Street
Gratz, PA 17030
(717) 365-3300 Ext 2560
bsitlinger@miwd.com
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency American Architectural Manufacturers Association
Validated By Steven M. Urich, PE
Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2008
Equivalence of Product Standards
Certified By
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZFR6fGloOf5hOzl8F4bEmCHQ3z2amGBggplQ%3d%3d Page 1 of 5
I
Florida Building Code Online 3/14/17,10:12 PM
Product Approval Method Method 1 Option A
Date Submitted 07/13/2016
Date Validated 07/13/2016
Date Pending FBC Approval
Date Approved 07/17/2016
Summaq of Products
FL# Model, Number or Name Description
17676.1 3540 SH 3604 Fin Frame
Limits of Use Certification Agency Certificate j
Approved for use in HVHZ: No FL17676 R3 C CAC APC 3540 Fin 36x74.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 04/12/2017
Design Pressure: +35/-50 Installation Instructions
Other: LC-PG35. Units must be glazed in accordance with FL17676 R3 II Install -3540 SH 36 x74 Fin.pdf
ASTM E1300-04. Verified By: American Architectural Manufacturers Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
t
17676.2 3540 SH 36x84 Fin Frame
Limits of Use Certification Agency Certificate I
Approved for use in HVHZ: No FL17676 R C_CAC APC 3540 Fin 36x84.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 07/27/2020
Design Pressure: +40/-50 Installation Instructions
Other: LC-PG40. Units must be glazed in accordance with FL17676 R3 II Install -3540 SH Fin 36x84.pdf
ASTM E1300-04. Verified By: American Architectural Manufacturers Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.3 3540 SH 40x66 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 R3 C_CAC APC A3485.01.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date j
Impact Resistant: No 08/26/2019
Design Pressure: +35/-45 Installation Instructions I
Other: R-PG35. Units must be glazed in accordance with FL17676 R3 II Install-3540 SH Fin 40x66.pdf
ASTM E1300-04. Verified By: American Architectural Manufacturers Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.4 3540 SH 44x63 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 RRC_CAC_APC 3540 Fin 44x63.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 05/26/2020
Design Pressure: +40/-47 Installation Instructions
Other: R-PG40. Units must be glazed in accordance with FL17676 R3 II Install -3540 SH Fin 44x63.pdf i
ASTM E1300-04. Verified By: American Architectural Manufacturers Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.5 3540 SH 4402 Fin Frame I
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 R3 C_CAC APC 3540 Fin 44x72.pdf-
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 08/01/2017
Design Pressure: +35/-47 Installation Instructions
Other: R-PG35. Units must be glazed in accordance with FL17676 R3 II Install-3540 SH Fin 4402.0
ASTM E1300-04. Verified By: American Architectural Manufacturers Association
Created by Independent Third Party:
https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvFGYZsjrZFR6fGloOf5hOzl8F4bEmCHQ3z2amGBggplQ%3d%3d Page 2 of 5
ELEVATION
Notes:
W.
HEAD DETAIL
1. Installation depicted based off of structural
2" #yp. test report #C7327.01-109-47.
12" o.c" �. SHEATHING/OSB
max. 2. Wood screws,shall satisfy the National
2' typ.. SIZE HEADER AS NEEDED Design Specification for Wood
I-�— FLASHING Construction for material type and
f I BY OTHERS CAULK UNDER NAILING dimensional requirements.
FIN ENTIRE PERIMETER
12' o.c. BEFORE FASTENING. 3. Wood buck installations are assumed 2x
max. /
— S-P-F (G=0.42) or denser. Buck width
Anchor shall be greater than thewindow frame.
(See Sectldn Details) width. Tapered or partial width bucks
are not allowed. Wood buck shallbe
secured to the structure to resist all
design loads.
Q 8(�
4. Wood screw. lengths shall be sufficient
MINIMUM to guarantee 1-1/4" penetration into
1 1/4 INCH
PENETRATION wood buck. .
INTO STUD
5. Maximum shim thickness of 1/4'
permitted at each fastener location.
Shims shall be load bearing, non-
compressible type.
6. These drawings depict the details
5 necessary to meet structural load
requirements. They do not address the
air infiltration, water penetration, intrusion
Min Edge 7/16" SHIM AS or thermal performance requirements of
REQUIRED the.installation.
DRYWALL 7, Installation shown is that of the test
Window for the size shown and the
design pressure claimed. For window
#8 X 1-5/8'SCREW(SHOWN'WITH:�" SHEATHING) sizes smaller than shown, locate
MUST ACHIEVE 1-1/4" PENETRATION fasteners apfrom:comers and no
INTO SNDs more than 12t'* o center.center. Design
pressures of smaller window sites are
A's&CLEARANCE limited to that of the test window.
(ALL FOUR SIDES) SILL DETAIL
SIZE AND DESIGN PRESSURE CHART
FASTENER TYPE AND SPACING SHOWN WILL ALLOW DESIGN PRESSURES UP TO+35/ —50 UNITS UP TO 36"x 74'
(SEE TEST REPORTS FOR INDIVIDUAL UNIT SIZE AND APPLICABLE DESIGN PRESSURE LIMITATIONS)
SHEATHING
Min Edge 7/16" Mmu" .w um
Its INSTALLATION INSTRUCTIONS V.M.R. 12-14-09
& FASTENER SCHEDULE — FIN—
JAMB DETAIL
�C-NAIL FIN' IS A GENERIC TERM WHICH Windows&Doors 3J4O Single Hung NONE 1 �1
cxc ro. �v.
MEANS MOUNTING FLANGE'. Gratz,PA 3540-3240 SH FIN -
CNOT TO BE CONFUSED WITH '1/2' FRONT FLANGE)
�j