Loading...
HomeMy WebLinkAboutProduct Approval wig i ' A A l e / BCIS Home Log In User Registration Hot Topic Submit Surcharge Stats&Facts G Publications FBC Staff BCIS Site Map I Links Search a Product Approval Florid ! r Q' USER:Public User R#,c+aixJlA.jr.in Product Approval Menu>Product or Application Search>Application List>Application Detail R FL# FL17347-R1 Application Type Revision ��� , Code Version 2014 2 0 2ol(q7 Application Status Approved PERMITTING St. Lucie County, FL Comments Archived ❑ Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbidgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies . Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer I] Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King,P.E. ❑ Validation Checklist-Hardcopy Received Certificate of Independence FL17347 R1 COI Certificate Of Indeoendence.odf Referenced Standard and Year(of Standard) Standard Year 101/I.S.2/NAFS 2002 AAMA/WDMA/CSA101/I.S.2/A440 2008 ASTM E330 2002 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/16/2015 Date Validated 04/22/2015 Date Pending FBC Approval 04/24/2015 Date Approved 06/23/2015 Summary of Products FL# Model,Number or Name Description 17347.1 a.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.1 for any additional use limitations, FL17347 R1 AE EVAL 17347.1.1)df installation instructions and product particulars. Created by Independent Third Party:Yes 17347.2 b.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.2 for any additional use limitations, FL17347 R1 AE EVAL 17347.2.odf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.3 c.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.3 for any additional use limitations, FL17347 RS AE EVAL 17347.3.1)df installation instructions and product particulars. Created by Independent Third Party:Yes 17347.4 d.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.4 for any additional use limitations, FL17347 R1 AE EVAL 17347.4.odf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.5 e.Fiberglass Door "Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 RI II Inst 17347.5.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports err,:See INST 17347.5 for any additional use limitations, FL17347 Rl AE EVAL 17347.S.odf m i instructions and product particulars. Created by Independent Third Party:Yes 17347.6 f.Fiberglass Door "Impact"Fiberglass Glazed Door-Double with or without Sidelites()X or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height i of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.6 for any additional use limitations, FL17347 R1 AE EVAL 17347.6.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.7 g.Fiberglass Door "Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 RI II Inst 17347.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.7 for any additional use limitations, FL17347 R1 AE EVAL 17347.7.Ddf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.8 h.Fiberglass Door "-Impact"Fiberglass Glazed Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.8.1)df Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.8 for any additional use limitations, FL17347 R1 AE EVAL 17347.8.odf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.9 i.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.9 for any additional use limitations, FL17347 R1 AE EVAL 17347.9.odf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.10 j.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.10.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.10 for any additional use FL17347 RI AE EVAL 17347.10.odf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.11 k.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.11.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.11 for any additional use FL17347 R1 AE EVAL 17347.11.odf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.12 I.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 RI II Inst 17347.12.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.12 for any additional use FL17347 R1 AE EVAL 17347.12.1)df limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.13 rMberglass Door "Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R1 II Inst 17347.13.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes plastpro 74'MAX.OVERALL FRAME WIDTH 5200 W. CENTURY BLVD. ��.... .o LOS ANGELES, CA 90045 1111111r%" ��` ` o on..m Z p UN f'J C 5E. pZO -0. l<LO Jm CW C7 N M O t Wc9 �z 00 mda� GLAZED FIBERGLASS DOORS � LL3 x e x E oz DOUBLES Ira w/ or w/o SIDELITES oz INSWING/OUTSWINGLi "IMPACT' J GENERAL NOTES a� 148.5"MAX.OVERALL FRAME WIDTH 03 � 1. This product has been evaluated and is in compliance with the 5th Edition(2014) 74"MAX FRAME WIDTH 37.2SMAX. o Florida Building Code(FBC)structural requirements excluding the"High Velocity �i� ��FRAME WIDTH o w o Hurricane Zone"(HVHZ). a a 2. Product anchors shall be as listed and spaced as shown on details.Anchor m embedment to base material shall be beyond wall dressing or stucco. !E m 2 U 3. When used in areas requiring wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant z ? D covering.This product meets missile level"D"and excludes Wind Zone 4 as g O X 0 X O N a N defined in ASTM El 996 and Section 1609.1.2.2 of the FBC. g o o_ 0 V)4. For 2x stud framing construction,anchoring of these units shall be the same as 'o that shown for 2x buck masonry construction. m o tc 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. ' Jk TABLE OF CONTENTS o SHEET# DESCRIP110N 1 Typical elevations,design pressures&general notes DESIGN PRESSURE DESfGN PRESSURE, o 2 Door&Sidelite panel details MAX Z M FRAE 10 8 14 PS PS 3 Lite frame glazing details CONFIG INSWING OUTS NG rH 4 Elevations DIMENSfON pOS ', NEG POS NEG: i sruF N.T.S. 5 Vertical cross sections D JK � XX 74.0"x 82.0" 6 Horizontal cross sections OXXO 148.5"x 82.0" +50.0 -50.0 +50.0 -50.0 CKK.er. LFS s" —7 ,Tuck anchoring DRAWING NO-' g 1 Frame anchoring&hardware details FL-17347.6 9 Bill of materials and components sHa:r_L or 9 a „'I 0.7” _ EXTERIOR 23' 4„ ••a i i .e. • LgS rMl 4 ♦ • •'%: .:a.'. • �'�.>�'' ... 'ki`�� ;>� CAP(PVC) HINGE STILE(LVLINTERIOR LATCH STILE(LVL CAP(PVC) ••• // rrl t1••� $ a • •:• •�.:�;-�� G1 G2 TOP RAIL '•:_"�. E oz_m°n (COMP.) ... (� S u 9 p o a t HORIZONTAL CROSS SECTION '• o 35.75'MAX.PANEL 'v WIDTH 'v D o J 1-/10 Ur � Q e v Gl G2 l am oa EXTERIOR INTERIOR c f, m x DOOR LOCK HARDWARETABIE 'm MANUFACNRER „•MODEL O KMKSEI KNOB: SERIES(400) ,..•S;••. a DEADBOLT: SERIES(660) g' HANDLESEE'F'SERIES(F60) •e"• - r SCHIAGE DEADSOLT: 'P'SEUES(F60) 8 SCHLAGE KNOB: 'F'SERIES(FID) Ln DEADBOLT: '6'SERIES(B60/62) FOAM CORE ','j'a.' �j SEE DOOR LOCK KNOB CIRRUS lop C (POLYURETHANE- x HARDWARE TABLE YALE 1.9 PCF MIN.) DPAD80LT: 820 SINGLE CYLINDER FIBERGLASS SKIN (0.075„MIN.THK.) :'• T! m 2 :e PLASTPRO DOOR PANQ BOTTOM RAIL ~ , 'r'•�'�.11• ^0 0 (COMP.) v 50 PLASTPRO SIDELRE PANQ ah 1 D 8 14 i sous N.T.S. Dwm BY. JK m s 22 VERTICAL CROSS SECTION Br: LFSa - 47.6 3a 0 s1� 2 a 9 p i� a 24.22"MAX. MAX.LIGHT _ �•` 0, 2350" m FRAME WIDTH FRAME WIDTH o A•• •� ci 20,5 MAX. 20.50•MAX. _: ,5 <-z D.L.O.WIDTH D.L.O.WIDTHI Z * �•O` .d �... ............. zu�i1.0 n "J"111111% ZO no 10 ZO o l UN•• Z 0V x O U rm mcw 03 O � n�� gNg 90a d m a133d _ _ • c o ~E ci #7-19X1.3/4"PPH w �p oZ SELF-DRIWNGSMS ci v fJ� ci b� #10 X 1-3/4"PPH SMS 0.71" o wa o 1.59"--{ �o —H �4.2Sm P) (TYP.) o 0.84" ODL LITE FRAME c' RSL LTTE FRAME o_ J (7 ,m n� ^� E`Z 1.86" d 3A OOLLREFRAME 3B RSLIJIEFUME Aluminum PVC c V) DOW"5 DOW 995 3A STRUCTURAL HOT BUTYL STRUCTURAL I/2'GLASS BITE $ N SILICONE ILICONE 5/8"GLASSBITE SEALANT 1-1/4"OVERALLGLASS THK. 1"OVERALL GLASS THK. (ADCO) EXTERIOR EXTERIOR ;,,} . 1/8"ANNEAL(DGLASS I/8"ANNEALED GLASS t. , 0.090 SAFLEX®PVB 0.09("SAFLEe PVB NTERLAYER i INTERLAYER I/8"ANNEALED GLASS < I/W ANNEALED GLASS ap AIR SPACE Ifir IR TEMPERED GLASS 1/8"TEMPERED GLASSPACE O o° INTERIOR INTERIOR Z INTERCEPT SPACER DAIS: 1018114 = SCREW CAP 1/2"NON-GROOVESWIGGLEsum N.LS. 5 W/ DELCHEM#80 POLYSULFIDE #7-19 X 1�/4"PPH m #7-19SELF- RIWNGSMS #10X 1-3/4"PPHSMS 3B 1/9-BACKFILL Do.im. JK SCHK.Err. LFS ; DRAWING NO.: ¢ GLAZING DETAIL GLAZING DETAIL ° GI ODL Ute Frame G2 RSL Life Frame FL-17347.6 N 3 sxeaT_jL of, 9 a RACrentWastpm,Inc PERMANENT\RorNa Product ApprovalsVI-1734AC-Drawings\CumntX L•173475-.B.dwg,4.6 I P� X N N rr1 N m N 0 00 00 \` 00 0 Z p,P Z PO. N A N A Nm NOD Q N w N P d P A .......... No.43409 ;* rP o PRODIJ FlB LASS DOOR Lyndon F. Schmidt �' ............. � ����``• yOl PART OR ASSEMBLY: K B.UILDING CONSULTANTS. INC. ING UPDATE TO S1H ED. 2014 FBC JK . oz230, rnValri , FL 33595 DATE 13Y Phone Phone No.: 813.859.9197 REVISIONS FBPE CA No. 9813 0 2014 R.W.BUILOINO CONSULT S INC. D EE D � D � `9�,•• �'' N CW 0 o a gzd C C to 9macw a uy d o a F 'mdaf° 40 7 SEE NOTE 1 a Z � 1 � � 3 40 �+? 50 to z 1 o tj INTERIOR EXTERIOR 1 0 6 •INTERIOR EXTERIOR INTERIOR EXTERIOR 24AI 0 cc UZ 1 VERTICAL CROSS SECTION 2 VERTICAL CROSS SECTION 3 VERTICAL CROSS SECTION �cFs $ Inswing s own Ou ng similar $ In ngg s own Ou ng s m or $ n ngng wn Ou sswng s m lar a g y 2X Bucg Constnrction 1X BuckCoastructbn 2X Buck Construction > m IR NOTE. 1.Spacing for item J®head&sill:6"from each end, o) 1@ centerline.2 additional at T&4Z from end D d a adjacent to door. m 8 VERTICAL CROSS SECTION $ AOAsa INTERIOR EXTERIOR INTERIOR EXTERIOR fl! 3 INTERIOR EXTERIOR INTERIOR 3 40 EXTERIOR N 50 0 6 25 22 40 SEE NOTE 1 50 B rn 21 27 SEE NOTE 1 It Ga 20 26 25 23 0 3 z � •e• n �Z V 0 who 1018114 ? D D D D scuF N.T.S. DM BY. JK n CM er: LFS 4 VERTICAL CROSS SECTION 5 VERTICAL CROSS SECTION 6 VERTICAL CROSS SECTION 7 VERTICAL CROSS SECTION DPAMo NO. v $ Inywing sill $ Outm ng sid Inswings� Inswng sia FL-17347.6 n mw 5 or_,9 n a vl �� 0.15 EE C ``��. ..CSINK F CSWK C C'SWK •T Z m SEE NOTE 1 F �,• z U210 10 n7 EXTERIOR 7 EXTERIOR1j *••.{ z° 4p p 111'11{ cg •e G rY1t 5 E Z_ O Z� m 8 u� 9 oa n O a:= LZ�I 9 " Cz 9 5p 9 INTERIOR INTERIOR J 9 11 9 11 a 1 HORIZONTAL CROSS SEC110N 2 HORIZONTAL CROSS SEC110N 3 HORIZONTAL CROSS SECTION o 6 Insvnngg shown outsnnng stm(larl 6 I ngg shown Outsw ng sunilar 6 InsNnngg s own ou ng mils 2X Buck Construction 2X Buck ConsUuct on 1X Buck Construction m g N� m � a o o Lh o.TNC �m C'SWK d K 1 a w SEE NOTE 1 p •: N y 50 33 8 o 9 406 [OR M EXTERIOR Zx u 10 gi • � _ 10, SEE NOTE 1 9 INTERIOR INTERIOR o Fm 11 40 12 40 50 -z° v DATE: 10 8 14 z NOTE: e HORIZONTAL CROSS SECTION 6 HORIZONTAL CROSS SECTION � N.T.S. 1.Spacing for item 1:6"from each end 6 Insw ng shown out ng similar 6 nswrng shown outsMng similar) 4 HORIZONTAL CROSS SECTION owe.ee JK m [Strown w/out einforcemenfJ 6 In ng shown Outswm9 lor) 3 s and 3 more equally spaced along 1 X Buck Construction uruwwo�: d sidefde jamb(5 total). a R.-17347.6 0 gp' SHEET 6 or 9 O iY R:\Oients\Piastpm,Inc PERMANENT\Nodtla Product AppmvaLs\F1-1734AC-DrawingslCurrent\FL-17347-5-B.dwg,7.6 O 3= -0 - XI o- v X t \O 16"O.C. P \` Max.�l RY) Nall\t to 'z A X O � as� v A 16"O.C. VYP) 1 MAX.(iYP) ...,�...... ��/moi ` No.43409 L _* yt c yt /f�a/moi R Q PRODUCT: D-lur PrMmmd By:� R PLASTPRO Lyndon F. Schmidt VZ o FIBERGLASS DOOR P.E No. 43409 w m PART OR ASSEMBLY: r� BUILDING CONSULTANTS, INC. Im v in A 1 t4 15 UPDATE TO 5TH ED. 2014 FBC JK BUCK ANCHORING �/�/ P.O. Box 230, Valrico, FL 33595 m NO DATE BY Phone No.: 813.859.9197 REVISIONS FBPE CA No. 9813 0 2014 R.W.BUILDING CONSUL--INC. T(TYP.) 6 P. 4"(TYP) 11 G 1 X BUCK SEE HINGE z Z'S' I I i I l DETAIL 1 _p; Z_- - MUCK m Fn i I O z' 6'm 2XREINF. p ^^ T�' O.j m F MUCK — '° 9 9 �� + 1 i� /i, ...... ''•`.� >>Am InH� o m= D IXBUCK e N ' v Z m o U HEADyJAMBS II _ HINGE DETAIL 1 ; i m T • (12)#8x7'PH (14)g6x2 PH `3 y 9 ota X X SELF-DRILLING SIMS SELFDRIWNGSMS [\`{� d SEE HINGE V E o z II G MUCK BUCK DETAIL 2 c p� MUCK U 2X REINF. NT— SILL(TYP.) — 0 i3 1 I io HINGE DETAIL 2 HINGEJAMB fq m o� o Endura DIP w ASTRAGAL SCREW LOCATIONS m6" 3"(IYP.) —�{ T(TYP.) 6"(TYP.) RYP) I 4"(TYP.) . v(TYP) I � a a I I i t I I I I I I I I I F ASTRAGAL STRIKE PLATE 'm p — (1.19"x325") ' O O 3 _ F MUCK _ _ — &, f12 0 D 1XBUCK I A N z HEAD&JAMBS B y (TYP.) — ASTRAGAL BOLT DETAIL O X X O Stoke Plate @ Head f{ `�_ U�_ 7 z m — SILL(TYP.) MULUiN O LATCHAND DEADBOLTDETAILS1TYPa g 17.111 1 1111 1 1 1 TI — 31T0BOLT HOLE wre 10/8/14 z v ASTRAGAL BOLT DETAIL ASTRAGALBOLTDETAILSCAM N.T.S. 3 Outswing Threshold Inswing Threshold mvc.ar JK m CM er: LFS 3 s FRAME ANCHORING HARDWARE DETAILS iz< FL-17347.6 ° 0 s stir-�L of 9 O" 8 a BILL OF MATERIALS ������� REM# DESCRIPUON MATERIAE �—4'56"—�-I `���A, •'.• •.���i� N A 2X FRAMING(G>=0.42) WOOD T— 4.56' °r' :� n B 2X BUCK(G>=0.42) WOOD C 1/4"MAX.SHIM SPACE L f? ��• * `— D 1/4"PFH CONCRETE SCREW ONCR(1-114'MIN.EMB.) STEEL II I c g I•�—2.44"—^i,—2.13'—JADA iHRESH0ID E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE 24 •..•, c ro ro F #100X21/7LPOW BLOCK FH WOOD CREW(Rn1S'MIN.ING TO E iTg C90 STEEL 1 POLY FIBER JAMS D� ''���ql(*1111���� o n fe z° G 3/16"PFH CONCRETE SCREW(1-1/4"MIN.EMB.) STEEL v 0 x i d J #10 X 2-1/2"PFH WOOD SCREW STEEL e E m ?m o° 10 IWL K #10 X 7'PFH WOOD SCREW STEEL Tq d e `� m a`a� M #8 X 7'PH SMS STEEL 1 POLY FIBER JAMB COMP. Z 5 2X REINFORCEMENT (G>=0.55) WOOD I I I ' p 6 DOOR SWEEP PVC tom---4.56- 7 .56 -7 WEATHERSTRIP(ENDURA FORCE 5) FOAM INSWING THRESHOLD 22 OUTSWING THRESHOLD 8 WEATHERSTRIP(Q LON) FOAM 20 Endura(ZSedes) Endura(Z-Series) 9 #9 x 3/4"PFH WOOD SCREW STEEL 11 4"X 4"HINGE STEEL 21" SIDELRE o 3 SIDELRE ADAPTER &o 12 LATCH STRIKE PLATE STEEL ADAPTER u, } �o 13 DEADBOLT STRIKE PLATE STEEL a 20 INSWING THRESHOLD ALUM/COMP a, 8 08 0o 21 INSWING THRESHOLD W/SIDEUTE ADAPTER ALUM/COMP m 22 OUTSWING THRESHOLD ALUM/COMP 23 OUTSWING THRESHOLD W/SIDELiTE ADAPTER ALUM/COMPm oPI D 24 ADA THRESHOLD ALUM 4.56" Imo--456" —I �I a 25 OUTSWING THRESHOLD ALUM/WOOD INSWING THRESHOLD w SIDELI(E ADAPTER OUTSWING iHRESHOLD w SIDELITEADAPTER 26 INSWING THRESHOLD ALUM/WOOD 21 Endum Rdetes) 23 ( ) 27 INSWING THRESHOLD W/SIDELiTE ADAPTER ALUM/WOOD Endura}Sates 33 ASTRAGAL(DLP OR ENDURA) ALUM 40 DOOR PANEL 4.56" 4.57" 50 SIDELfTE PANEL N z i Z 0 U F 25 OUTSWING THRESHOLD 26 INSWING THRESHOLD Ix DLP DLP A CONCREfEANCHOR NOTES: 1.concrete anchor locations of the comers maybe adjusted to maintain the min. edge distance to mortarjoints. 1.75' ?2.Concrete anchorlocations noted osMAX.ON CENTER"mustbe adjusted to 1,75" E maintain the min.edge distance to mortarjoints,addtional concrete anchorsmay be required to ensure the MAX.ON CE3dW dimension are not exceeded.3.Concrete anchor table:HANCHOR MIN 'i o TOMASONRY ". i0 ADJAEENT 'i "0 SLIDE T In 5/16"0 SLIDE BOLT SIZE EMBEDMENT 5/16 BOL TYPE ....:.: .:ANCHOR f. C4 (2"THROW® (z"THROW® uTe 10/8/14 i ITW BUILDEX 3/16- 1-1/4' 3" 1.1 2" EACH END) EACH END) SCALE: N.T.S. ° TAPCON. 14" 1.1/4" Y 4" 1"i � ELCO BOLT RETAINER II I �•�. JK m it ULTRACOIF 1/4" 1-1/4" 1" 4" CONCEALED t�457" CHx.Yr. LFS 3 _ ¢ 2 WOOD SCREW INSTALLATION NOTES: ASTRAGAL STIFFENER ENDURA ASTRAGAL < 33 33 INSWINGTHRESHOLDW SiDELREADAPTER FL-17347.6 i.Maintain a minimum 5/8"edge distance,1"end distance.&T"o.c.spacing of DLP Ultimote Hunicane 2� a nwood screws to prevent The splitting of wood. DLP SHEET 9 of 9 6 a'