Loading...
HomeMy WebLinkAboutProduct Review Affidavit 12222/2096 Florida Building Code Online BCIS Home ; Log In I User Registration I Hot Topics Submit surcharge ! Stats B Facts € Publications F8C Staff BCIS Site Map ? Links ; Search i Product Approval USER:Public User Product Approval Menu>Product or An Search>Aaalication Lis#>Application Detail I # F �y FL# FL10674-R12 # s Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived i Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY; Toledo,OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from la Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-;Hardcopy!Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida incense PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE i4�i Validation Checklist;-Hardcopy Received Certificate of Independence FL10674 R12 COI 2016 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By httpsJ/www.floridabLilding.orgtpr/pr app dd.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEA65bxB8ctyag%3d%3d 1/2 I'LJ11'LU16 Florida Building Code Online Sections from the Code i i Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 SummarV of Products FL# Model,Number or Name ;Description j 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,j5-tab, laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use 'Installation Instructions Approved for use in HVHZ: No 1 FL10674 R12 II 2016 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes i SHINGLES FL10674-R12 pdf Impact Resistant: N/A ? Verified By: Robert J..'M. Nieminen PE- 59166 i Design Pressure: N/A Created by Independent Third Party: Yes 1 Other: Refer to ER, Section 5. ;Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT ( j SHINGLES FL10674-R12.Ddf Created by Independent Third Party: Yes $aC3i [4f:Xt Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-'487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement:::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: NO IN Credit`Card 'Safe j. I j I i https://www.floridabuilding.org/pr/pr_app dU.aspx?param=wGEVXQwtDgtBNbEY5V%g2boQT%2b6w7ahReglCQ8ucR6izE465bxB8ctyag%3d%3d 2/2 - EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 ����'� ERD 353 CHRISTIAN STREET,UNIT#13 G i OXFORD,CT 06478 i PHONE:(203)262-9245 j FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R7 One Owens Corning Parkway FL10674-1112 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th jEdition (2014) ,Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as ,the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. TrinityIERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity;)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall bel done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared b : ' p Y Robert J.M.Nieminen,P.E. +�,FS�^';,`��.4 The facsimile seal appearing vas authorized by RobertNiernmen, P.E.on 04/18/2016.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. I 2. Trinity]ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinityiERD nor Robert Nieminen, P.E. are,;in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. I, . ./ � QTRINITY|~- -- ' | ! ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing . Sub-Category: Asphalt Shingles ' Compliance Statement: Owens Corning Asphalt Roof Shingles,as producedby Owens Corning,have demonstrated compliance with the following sections nfthe Florida Building Code and Florida Buil ding Code, Res�enta| Volume through testing in accordance w�hthe foUStandards, Compliance isSubject tthe Installation Requirements and Limitations/Conditions ofUse set forth herein. / JL B#m/oAmDs: . Section Property Standard ' Year 1507.2.5,R905.2.4 Physical Properties ASTM o34aZ 7009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 I009 1507.2.7.1,neOszsz Wind 4a7xxo7z�� /| 2008 . . � n � . 3. REFERENCES: � Entity §xamina@gReference Date UL LLc(CsRy*2o) Physicals&Wind Resistance File R2453,Vol.113 02/15/2007 & i d Resistance Znz2oszsn2«ss ' 05/16/2012u��c(ccRoozs} rhvoca|� �ance vvn n UL LLc(nSTg6Z8) Physical 8acAunZa� / 04/18/2006o . � oLLLC(Tsr e28) Wind Resistance 11cA34308 02Y18/2012 UL Luc(TsTyo2u) Physicals&Wind Resistance 4786093137 02/01/2014 UL Luc(T3T9628) Wind Resistance 4786126532 | 02/10/2014 UL LLc(nST9aIn) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628' Physical Properties �s� s � icaUnn|ette, 10/02/2015 Miami-Dade<[s15sz pmcHV*ZCompliance VnriwusNoAs / Various UL LLC (QVAe625) Quality Control Service Confirmation,R24sJ Exp.08/242017 i '| 4. PRODUCT DESCRIPTION: ` 4.1 Asphalt Shingles: '. ° .�. 4.1-1 �assc andSupreme°are fiberglass reinforced,3-tabasphalt roof shingles. ` i 4.1'2 Berkshire*are fiber fiberglass 4�abaspha�roofsh��es " ' | ' 4.13 Devumohire=are fiberglass reinforced,5-tabasphalt roof shingles. . 4.1.4 Duration , TruDefinUdon Duration , Duration Premium Cool, TrQeO Ki Duration Des Color Collection, TruDe8nibun~UakridAe~, nakridge~ and VVeatherGuand~ HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshine° Hip& Ridge Shingles, High Ridge, VYeathepGunrd~ HPHip!&Ridge.Shingles, ProEdgeHip &Ridge Shingles andDuraKi6germ Hip&Ridge Shingles are fiberglass reinforce'd,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strip�for asphalt roof shingles. S' LIMITATIONS: / 5.1 This is building code evaluation. Neither Th itylERD nor Robert Niemi /en, P.E. are, in anyway the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,iskwouused for permitting ordesign guidance unless retained specificaUyforthat|purpuse�' 52 This EvaluationR �is not. s Report n 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings ofthis product. Exterior Research and Design,uc 'Evaluation Report oaze4n.0a.10-11r Certificate,/Authorization xsno | p1.1067+1112 ' Revision 7:04/18/2016 ^ Page zma � l TRINITY'ERD ' I 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasa=150 mph (V„It=194 mph). Refer to,Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6_1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturers current published instructions, using minimum four (4) nails per shingle in accordance with FBC Section's 1507.2 or R905.2, with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle. ➢ Devonshire'TM shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five'(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt tutderlaymant DeckFeRuadert5yrnnet Deck aa�+� Weatlrad oclr� Seff-adhered, yinadeymeat Weatherl ock° undedayment C Drip.- r Diip.edga -- Urgedge edge edge kails located tUa loreted 2"-t3'.heiim cave 2=3'lrom gave Idstall first Se -sealing adhesive SatiaeaGng adhesire Starter Sttipp Ifkst5teirStrip P16s shirtglewitti positioned whhe'rernoved posilionedalongcave. 6"Temaved Starter Strip shingle overhangs eaves and rakes rlP-Y," Starter SA,p Me evo&angs sam and rakes t/4'-314° Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certtricate of Authorization 1/9503 FL10674-1112 Revision 7:04/18/2016 Page 3 of 8 � r �)TRINITYESD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area pare Normal Mansard or Area para Wind Areas Nigh Wind desvanes y Wind Areas High Wind de"anes y Area para vientos normeles Areas vientos fuestea Area pare.vienros normales Areas vientosfoertes z• r. t (A} t2 t t' 2- .I I. 5'Exposure 6 b(8"Ettpoaure Expoaieidn Ewosisldn 6.2.7 Minimum Nailing—Berkshire®: I Sea�iR ship Sealant strip is fire de selkdor ',a tira de seAador S,h' 9,yt q w. 8"A,.1 r r I Standard Fastening Pattern 6-Nail Fastening Pattern � I Seaiatrtstrip � •..ta.tuade seRadw. I ' � :s art s pit sir sJ, r 2- itro5to ,. yceinerit. Cerrie+rto"detecAoda aslaha Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-117 Certificate ofAuthorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 4 of 8 ;I "'-JTRINI-rYjERD 6.2.8 Minimum Nailing—Devonshire'": I ' 7" 7 e N 41 , CJ�m Nails 5�B'expgsute Sealant location "'' � � �`' Exposid6n de 5.5/8 ping Ubicscibn del sudor >x• , c . Ten t*Spots of!Asphalt Roof Cemern Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—Duration®,Tru Definition® Duration, Duration® Premium Cool &TruDefinition® Durationm Designer Color Collection: 4 flail Fastening Pattem .6-Nag Fastening Pattern _ Is"O l�I®hsrenGg,arefwjmh ! S"genmi®tasWitng aria rrttllh Nan,Typical W4�l �•' tz lrRR KZ wa�ssB• �� �'" H.r y st1a� Ma Standard Fastening Pattern 6-Nail Fastening Pattern Fasftning fcr'Stopes Greaw Than 2l:l2 9met}olll9ts9"Mngeeeewi6tA i 6d;B^SSB• Ile, III .. Fowl•Spc"sotAspoeli 2oollgg Gemm�t , Mansard or Steep Slope Fastening Pattern i I i Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-117 CertTicate of Authorization 119503 FL10674-R12 Revision 7:04/18/2016 Page 5 of 8 , I I I I ERD T�iN�TY� 6.2.1 Minimum Nailing—TruDefinition®Oakridge®,Oakridge®: 4'Nail.Pattem :6 Nall P&OM •Esgr(ema'ton:4 davos� Esquema coh:S dairos: I I , V Imo. rr.—a►1 IE— �z°—�1 I , I 5518 Expasure Natls 5518 Exposure P kJ C/aiws' xP? P3 d+P .: Cf jos ! EipasrgprfdeG518•u E srttdnck6518 55f8 " asure 5618" suis 6rpudacn.de'S�JSDtt1¢ <Earposlaoir de 56/8ptitg. Standard Fastening Pattern 6-Nail Fastening Pattern I Fastening for Slopes GmaterTf vn 21:12 Se.pa69 fnstonMg n vdm , I/Btl,.TypMa1 I ur yr �. Rali Pau V SPM4fA.0.ft F.fl aC...t Mansard or Steep Slope Fastening Pattern i 6.2.1 Minimum Nailing—WeatherGuardo HP: „ f I " moo 5M. 9 view 2. .1 •ss• s :1} ❖�• '1fa� lfrB ft�ee i I Exterior Research and Design,LLC. Evaluation Report 037940.02.12-117 CertrTicate of Autharization 119503 FL10674-1112 Revision 7:04/18/2016 Page 6 of 8 I I I � � I TRINITY ERS 6_3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge,WeatherGuard®'HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4) nails per shingle. Installation of D.uraRidge'" Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle.! Refer, to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig..1 s Fig.2. I P„ —...p �BWnU .p TOPUit+iu -idelheW TOP Laltirafetl, I I I r Q 1 I al E>Q,asufe� 8" ml 8i 1 � ( I ( 6.3.4 Minimum Nailing—WeatherGuard°HP Hip and Ridge: Fig.A �4 4 , Fig.G;Hip;&Ridge°Shingle.Fastening PIs-Wap41gY/InC TopVlew i Olractbn / p, I I. I ! NaILs Naps 52 I I .. p: �61 �I EWOMM I Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 7 of 8 Ic T 1NITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: PrJsvailittg Standard Winci:I3irJ J:tian 5ol�lntStripPattern FAStoninR 8a Exposure Salient Emmen 714 J 7'h° 6`EIML tof Fasteners virile Roof Cement 6.3.6 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. F4vsrs#iilglY+dY3trsedan Tap*llew 1ltDadtbadamrantn'3�Aft Hiraei6ndalvigrin�ro�xnaadra 23/E Cbu A ?B. 'sly? Y V I i 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the'I required;classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order ito properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com J END OF EVALUATION REPORT- Exterior EPORT-Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certfcate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 8 of 8