Loading...
HomeMy WebLinkAboutProduct Approval 3/23/2017 Florida Building Code Online .. & "esslowl ftglat!i�­ - _ BCIS Home I Log In I Use,Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications 5i FBC Staff I BCIS Site Map I Links I Search br a R E C E I�'r D PEAR ro 79117 61 "'d .:° Product Approval . , .USER: Public User moi' Product Approval Menu>Application Detail ° FL# FL20461-RO Application Type New Code Version 2014 Application Status Approved Comments Archived [ 1 Product Manufacturer Therma-Tru Corpora t' n Address/Phone/Email 118 Industrial D " Edgerton 3517 98-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida gistered Architect or a Licensed Florida Professional Engin L. Evaluation -Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation&Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan 1. King, P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL20461 RO COI CERTIFICATE OF INDEPENDENCE xx.pdf Referenced Standard and Year(of Standard) Standard Year 101/I.S.2 1997 ASTM E330 2002 ASTM E331 2000 TAS 202 1994 Equivalence of Product Standards Certified By Sections from the Code http://floridabuilding.orgtpr/pr app dd.aspx?param=wGEVXQwtDgsJ9a49YAgXJkHOuUrrg6tbgJ5FL9rbc8eeC7w6lOwY%2fwp/aid*/o3d 1/6 3/23/2017 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 RO II INST 20461 5 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20461.5 for Design Pressure Ratings, any FL20461 RO AE 20461.5 EVAL.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For Fiber-Classic and Smooth-Star doors, this product approval requires the use of"J" part numbers for these doors, which have been stained or painted within six months of installation.) 20461.6 f.Therma-Tru Fiber-Classic and Nominal 8'0"Non-Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 RO II INST 20461.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20461.6 for Design Pressure Ratings, any FL20461 RO AE 20461.6 EVAL.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For Fiber-Classic and Smooth-Star doors, this product approval requires the use of"J" part numbers for these doors, which have been stained or painted within six months of installation.) 20461.7 g.Therma-Tru Fiber-Classic and Nominal 8'0"Non-Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 RO II INST 20461.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20461.7 for Design Pressure Ratings, any FL20461 RO AE 20461.7 EVAL.pdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For Fiber-Classic and Smooth-Star doors,this product approval requires the use of"J" part numbers for these doors, which have been stained or painted within six months of installation.) 20461.8 h.Therma-Tru Fiber-Classic and Nominal 8'0"Non-Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 RO II INST 20461.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20461.8 for Design Pressure Ratings, any FL20461 RO AE 20461.8 EVAL.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For Fiber-Classic and Smooth-Star doors,this product approval requires the use of"J" part numbers for these doors, which have been stained or painted within six months of installation.) 20461.9 i.Therma-Tru Fiber-Classic and Nominal 6'8"Non-Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 RO II INST 20461.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20461.9 for Design Pressure Ratings, any FL20461 RO AE 20461.9 EVAL.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For Fiber-Classic and Smooth-Star doors roduct approval requires the use of"J" part be se doors, which have been stained or painted w' in six month of installation.) (tApproved 0 j.Therma-Tru Fiber-Classic and Nominal 6'8"Non-Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) f Use Installation Instructions f use in HVHZ: No FL20461 RO II INST 20461.10.odf e or use outside HVHZ:Yes Verified By: Lyndon F Schmidt, P.E. 43409 Resistant: No Created by Independent Third Party: Yes Pressure: N/A Evaluation Reports Other:See INST 20461.10 for Design Pressure Ratings, any http./Moridabuilding.org/pr/pr app_o.aspx?param=wGEVXQwtDgsJ9a49YAgXJkHOuUrrg6tbgJ5FL9rbc8eeC7w6lOwY%2fw%3d%3d 316 ' `��ltllllllrrlj THERMAITRU® DOORS =N'' zd ,/,A$ Fiber-Classic. & -St-a '��� *' 5111 1 Ch m'y UN•: 9 0 ozd COMPOSITE EDGE g 9 mCc 5325"MAX WIDTH FRAME 68.75"MAX O.A.FRAME WIDTH ` a v m a a fE LAZED FIBERGLASS SINGLE DOOR ' 4 15.5"MAX. 15.5'MAX. `o z w/ SIDELiTE(S) F FRAME WIDTH o° 3a 37.7 ' 37.75'MAX INS WING/OUTS WING Y E WIDTH FRAME WIDTH Z �o "NON-IMPACT' WZ ,� - - o zw GENERAL TES - f� f 1. Thip s 1:1!1: t h cas be valuated and is in ce with the 5th Edition(2014)Florida z � Building Code(FBC)structura requirements excluding the"High Velocity Hurricane Zone' 3 3 �� z (HVHZ). z o O o X X s` 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to o 0 &I a base material shall be beyond wall dressing or stucco. W _ } 6 0]w m 3. When used in areas requiring wind bome debris protection,this product is required to be protected with an impact resistant covering that complies with Section 1609.1.2 of the FBC. G 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for ` f' 2x buck masonry construction. z o r. 5. Site conditions that deviate from the details of this drawing require further V' engineering analysis by a licensed engineer or registered architect. 6. HDer-Classic&Smooth-Star Door and Sidelite panels require the use of"J"part $ numbers and must be stained or painted within six months of installation. Z n m w i 11 e TABLE OF CONTENTS DESIGN PRESSURE(PSF) DESIGN PRESSURE(PSI) .1 SHEET# DESCRIPTION SHEET# DESCRIPTION CONFIGURATION INSWING OUTSWWG o 0 1 Typical Elevations,Design Pressures&General Notes 9 Vertical Cross Sections(Thresholds) POSITIVE NEGATIVE POSITIVE NEGATIVE Z ° 2 Door Panel Details 10 Buck Anchoring w,F 611116 i 3 Door Panel Details 11 Frame Anchoring XO,OX,OXO +45.0 -50.0 +45.0 -45.0 Smc-c. N.T.S. 4 Sidelite Panel Details 12 Hardware Details MO.Gr: JK m 5 Elevations 13 Glazing details See Sheet 5 for Hardware Specifications cxw BY. LFS 3 6 Horizontal&Vertical Cross Sections(2X Buck) 14 Components DRAr»DG No.: 7 Horizontal&Vertical Cross Sections(IX Buck) 15 Bill of Materials FL-20461.10 I 8 Horizontal&Vertical Cross Sections(Direct to Masonry) S—_L OF 15 " r� it ��Illllllf//// 1.15'MIN. Notes: E EMB.(Typ,) 1.Sidelite assembly screws located 7"from top and 14"from bottom& O:'••o ' N 2 more screws equally spaced between(4 screws total per side jamb). __; o �+ J_ n B E 2.Sldelite assembly screws located 3"from each end(2 screws along C . head jamb). N * E'i Q d n L 0.15'GSINK C L D '',i/// •````�``` o m m (gyp) 0.15'C-SINK . ° v ////•11 1 PI�``` z orim o 1 IT1 P) ° o n z n.' E v y 6i' an• SEE NOTE 1 >v o z o Z v ,v.r° °, r�1 i m m D e ae. 25 v 8w 9doa 6 0 ` a Y mda(a INTERIORB c d L oz o".. za 9 de e EE Fv 3a JS FO 23 24 EXTERIOR 40 41 42 Y I m �o 5 D • 43 44 45 6 1 OR z y�� w ° 1-114"MIN. L 29 1 �(_ ��' g NN EMB. P. 1-1/4"MIN. !2 N (Ty ) 41 42 60 EMB.(TYP.) EXTERIOR INTERIOR o ? o =� 1 HORIZONTAL CROSS SE CAON 43 44 45 2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTION &I U 6 Shown w/2X Buck 6 5hown w/2X Buck o. a Outswing shown(Inswing similar) Outswing shown(Inswing similar) 6 Outsswing shown f inswing similar) }m 1 p 1 F D y 0.15"CSINK 0.15'C-SINK v t (TyP) (T1'P) r` E > v N z SEE NOTE 125 SEE NOTE 1 v 2 6 25 6 B L z_d e �m -- C ti m � < � 25 0 N SEE NOTE 2 0 0 Y z a 50 L 50 60 50 N MSE: 6 1 16 60 23 40 41 42 40 41 42 27 60 sue N.T.S. ° INTE R EXTERIOR1^ DO•BY. JK m' 29 43 44 45 43 44 45 o cm Dr.. t_FS 3 5 HORIZONTAL CROSS SECTION 6 HORIZONTAL CROSS SECTION 4 VERTICAL CROSS SECTION o awwo r 6 Outswing Shown(Inswing similar) Outs n shown Insvnn s mi ar 6 Shown w/2X Buck FL-20461.10 6 9 9 Outswing shown(Inswing similar) sx�r 6 01,_ Notes: A. •, HjO��i 1.S1II Item#'s 17,18,32,34,35,36,37,38&39 are attached to jambs w/(3)#8 X 2-1/7'pfh screws at each end. ��4:) L N Sig Item#'s 16&33 are attached to jambs w/(2)#8 X 2-1/2'pfh screws at each end. aZ; X. W Sig Item#15 is attached to jambs utilizing(4)#10 X 1-1/7'pph screws at each end. _ Mgr y 2.Sidelite assembly screws located 4'from each end(2 screws along sill). 011% z6 tO O' � INTERIOR EXTERIOR INTERIOR EXTERIOR ///ip►►t o o;_ EXTERIOR INTERIOR ` 9 ,x z d E° Z 40 41 42 40 41 42 9 \\ m° a 43 44 45 8 43 44 45 C W 40 41 42 7 16 17 18 `y ` "g 9°r a a 38 39 32 33 34 35 36 37 44 45 E g z SEE NOTE 1 $$ v 4 SEE NOTE 1 ++ `;``. E E SEE NOTE 1 Etv Sd it li 1 M l l 1 A \' 7 yi. •"� > _ e• .. .°. �.. p.. � UCC m i5 r D Z^ �m D zn D �` o w m 1 VERTICAL CROSS SECTION Q 2 VERTICAL CROSS SECTION �3�VERTICAL CROSS SECTION d U-3 9 Inswing Sig 7 Inswing Sill 9 Outswing Sill a m INTERIOR EXTERIOR M. 50 60 EXTERIOR INTERIOR EXTERIOR INTERIOR V) SEE NOTE 2 z 32 33 34 35 36 37 38 39 50 60 16 17 18 2 40 41 42 77 Ej 43 44 45 10 75 SEE NOTE 2 e 15 E E 76 E g tj SEE NOTE 2 DATE: 611116 z z a D z d same N.T.S. �L I — 7 D 1 E-- owc.er JK m m � �J m cft m LFS 3 4 VERTICAL CROSS SECTION m 5 VERTICAL CROSS SECTION 6 VERTICAL CROSS SECTION otuwwc No 9 Public Access Sill 7 9 Inswing Sill 9 Out,,Mng Sol FL-20461.10 0 sNEEr 9 of 15 o a R:\Oientffherma Tru PERMANENT\A-Florida Product ApprovaLgV-20461 Structural TT 66\C-Dr ingsXR 20461(2014)\FL-2D461.9-16.dwg,102 v A _o ti 2: � <O O.tj—ks��40C 1 I I • �r- — v 7� ` r y � X O n X r r I I � )4"MAX. 6"(TYP.)--� �- O.C.(TYP.) � -a I n m n �o zti r�r�rr ti O <O p �O •...A �D CZ1 z �� _= ?O - 1 lx 1 O X X Y C C W n n I � 1 f r z^ 14"MAX. �^ e ITYP.)— �-- O.C.(TYP.) O m v v 0 w va X N / SCHM�� No- 434 9 T ' PRODUCT- D—nunitn Prop—d W. grATEpP r THERMA—TRU Lyndon, F. Schmidt 4��`•'•. Ofa9*�•''�` tv z Z FIBERGLASS DOOR P.E. No. 43409 i'' I' \`� PART OR ASSEMBLY- GA BUILDING CONSULTANTS.O Al Icnto rn FRAME ANCHORING u(P.O. Box 230, Valrico, FL 33595 o NO DATE BY Phone No..- 813.659.9197 REVISIONS FBPE C.A. No. 9813 0 201 6 R.W.BUILDING CONSULTANTS INC.