HomeMy WebLinkAboutDrawing 72" X 80" MAR 2 .9 20,ab PER VIITfI SIG S1. Lucie Ccunty, F REPLACE DOOR IN 1 OPENING ONLY. OPENING HAS EXISTING HURRICANE PROTECTION INSTALLED DURING HOME CONSTRUCTION PER HOMEOWNER. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 72 80 40.00 4 34.4 1 -37.6 FL20101.1 50.0 1 -50.0 KITCHEN-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 13 FT 6 IN O'DONNELL RESIDENCE 6106 ROLAND COURT DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA