HomeMy WebLinkAboutProject Information RECEI Av J 1 JJ �� 1�.� Egectricag Contract®r LOAD CALCULATION 3504 Fontansda Ave. Fort Pierce,FL 34947 Phone#772-46"500 FILE COPY Fax#772-466-0690 Beverly Hinton 108 Gotham Court 150 AMP SERVICE NEEDED Ft. Pierce,FL 34946 RE: Residence load calculation with new A/C General lighting 1362 sq.ft.X 3= 4,086 watts AM unit 7,500 watts Dryer 5,000 watts Range 8,000 watts Washer 2,000 watts Dishwasher/disposal 2,200 watts Refrigerator 1,500 watts Small appliances 3,000 watts Hot water heater 4,500 watts Sub total: 37,786 watts LOAD SUMMARY A/C @ 100% 7,500 watts 1st 10 kw @ 100% 7,500 watts Remainder @ 40% 12,115 watts Total: .27,115 watts=113 amps 240 Volts 150 AMP SERVICE NEEDED If you have any questions, or if we can be of any further assistance,please do not hesitate to call 772-466-0500. Eric Letourneau,President WirenutZ,Inc.