Egectricag Contract®r LOAD CALCULATION
3504 Fontansda Ave.
Fort Pierce,FL 34947
Phone#772-46"500 FILE COPY
Fax#772-466-0690
Beverly Hinton
108 Gotham Court 150 AMP SERVICE NEEDED
Ft. Pierce,FL 34946
RE: Residence load calculation with new A/C
General lighting 1362 sq.ft.X 3= 4,086 watts
AM unit 7,500 watts
Dryer 5,000 watts
Range 8,000 watts
Washer 2,000 watts
Dishwasher/disposal 2,200 watts
Refrigerator 1,500 watts
Small appliances 3,000 watts
Hot water heater 4,500 watts
Sub total: 37,786 watts
LOAD SUMMARY
A/C @ 100% 7,500 watts
1st 10 kw @ 100% 7,500 watts
Remainder @ 40% 12,115 watts
Total: .27,115 watts=113 amps
240 Volts
150 AMP SERVICE NEEDED
If you have any questions, or if we can be of any further assistance,please do not
hesitate to call 772-466-0500.
Eric Letourneau,President