HomeMy WebLinkAboutMisc Letters ? I I EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA.5V-CRIMP PANEL' j ' I FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL j FL 14645.3-R2 ROOFING METAL ROOFING I t Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street,Suite 200 Louisville,KY 40202 Telephone: (502) 8554300 j Fax: (502) 8554290 i i h! Prepared By: Bala Sockalingam, Ph.D.,P.E. Florida Professional Engineer#62240 1216 N Lansing Ave.,Suite C Tulsa,OK 74106 Telephone: (918)'492-5992 FAX: (866)366-1543 E This report consists of i Evaluation Report(3 Pages including cover) Installation Details (1 Page) o°°°P g0 C Kqt�� ecce oo��Q\:•�.�G E N S �9 eei No 62240 i b�. • � V i s ( Report No. C2010-3 STATE OF l w o Date: 3.27.15 :�0, -••,ANI P <v,•� ate ' , OR10 N`�oo e S .....•••�C;°0 is AL e °° i FL 14645.3-R2 C2010-A_. 3.27.15 r Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" thick plywood for new and existing constructions. Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or 48 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and @ 4" o.c. at edges New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c. (Factor of Safety=2) 74.8 psf @ fastener spacing of 16" o.c. 196.75 psf @ fastener spacing of 8" o.c. Fastener Pattern: Type: 49-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Lis: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity coo> Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2014 Section 1505 and current �r UR B -KED W. BS. 0.5. PLOT: MTE 5/25/15 EXISTING SHINGLESSEE DETAIL 2 SEE DETAIL NEW UNDERLAYMENT FASTENER AT PANEL FLAT 5V-CRIMP (OPTIONAL) (PANEL OVERLAP) NEW CONSTRUCTREQUIRED ION) ENDS ONLY. ��RA j REQUIRED OR PANEL a ii ii EXISTING UNDERLAYMENT '� �ANELFASTE'NFR PER ALLOWABLE - (OPTIONAL) MINIMUM ATTACHMENT: PRESSURE TABLE ON THIS SHEET. 8d x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD.SCREWS -- - _ - SPACED C� 6" O.C. MIN. THE FIELD`& - MIN. 2X_ WOOD RAFTER/JOIST/ 4" O.C. AT PLYWOOD EDGES TRUSS AT MAX. 24" O.C. -- -- TYPICAL PANEL INSTALLATION- X—SECTION FILE oo COPYOZZN �wo wo- #9-16 OR #10-14 WOODSCREWS ALLOWABLE UPLIFT PRESSURE NYS WITH SELF SEALING WASHER AT NEW UNDERLAYMENT MAXIMUM SPACING OF 36" O.C. FASTENER PRESSURE Lin NEW CONDONLY STRUCTION)R SPACINGpgF "fes I (IN) ( ) to mNwo EXISTING SHINGLES 5V-CRIMP (OPTIONAL) MIN 26 GA. 36 41.6 0� 16 74.8 LL In 8 196.75 � ui w C z EXISTING UNDERLAYMENT a o U e = N m (OPTIONAL) 191/32" HICK (MIN.) GENERAL NOTES: � a DETAIL 1 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE ; Z ?oq FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING In �r #9-16 OR #10-14 WOODSCREWS WIDTH OF PANEL = 24". zi' WITH SELF SEALING WASHER AT 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS � N NEW UNDERLAYMENT SPECIFIED ON THIS DRAWING. (REQUIRED ONLY FOR MAXIMUM SPACING OF 36" O.C. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS 3 U o NEW CONSTRUCTION) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS o ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. EXISTING SHINGLES - 5V-CRIMP 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA (OPTIONAL) MIN 26 GA. BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. EXISTING UNDERLAYMENT PLYWOOD (OPTIONAL) 19/32" THICK (MIN.) DETAIL2 SHEET.NO. 1: FL 14645.3-R2 C2010-3 3.27.15 Page 3 of 3 approved roofing materials directory or ASTM E108/UL790'report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date`7/21/05 (Tests#1 & 2) Project No. T240-09, Reporting Date!.9/2-2/09 Architectural Testing, Inc.—West Palm Beach, FL (Formerly Hurricane Test Laboratory;LLC) Project No. 0103-0712-09, Reporting Date 9/1/09