HomeMy WebLinkAboutProduct Approval (3) MAW
Mg. MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORYrC OF OURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATIO �gISN Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF
1 Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Cobra®Ridge Runnefrm Exhaust Vent for Roof Ridge
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA#13-0604.06 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
l NOA No.: 14-1022.10
MIAMIMADE COUNTY
� �'�� Expiration Date: 11/01/17
�FgjyasynApproval Date: 01/29/15
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Ventilation
Material: Plastic
Minimum Slope: 3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Product Dimensions Test Product
Specification Description
GAF Cobra®Ridge 20' Length(Roll) TAS 100 Low profile attic ridge vent in roll form for
Runnefrm Exhaust 11.5"Width installation under ridge shingles.
Vent for Roof Ridge .7"Height
MANUFACTURING LOCATION
1. Cumming,GA.
EVIDENCE SUBMITTED
Test Agency/Identifier Name Report Date
ETC Laboratories,Inc. ASTM D 1929 ETC-07-718-19959.0 09/27/07
ASTM D635 ETC-07-718-19959.0 09/27/07
ASTM D 2843 ETC-07-718-19959.0 09/27/07
PRI Construction Materials Technologies,Inc. ASTM G 26 GAF-138-02-06 02/09/07
TAS 100(A) GAF-138-02-04 02/09/07
TAS 100(A) GAF-439-02-01 05/21/13
NOA No.: 14-1022.10
MIAWDADE COUNTY Expiration Date: 11/01/17
Approval Date: 01/29/15
Page 2 of 4
APPROVED APPLICATIONS
Tradename: GAF Cobrao Ridge RunnerTM Exhaust Vent for Roof Ridge
System Type: Mechanical attachment of ridge vent.
Slot: Determine whether the rafters are truss or ridgepole construction. Chalk a cut line of
each side of ridge. Cut a 1 3/4" (no ridge board) or 31/4"(ridge board)maximum slot
along the apex of the roof by cutting 7/8" (no ridge board)or 15/8"(ridge board)on each
side of the ridge. The slot shall terminate 1 foot shorter at each end than the total length
of ridge vent used.
Installation: Place,center and conform the end of a piece of ridge vent at each end of slots. Mark the
location of the end of the baffle. Strike a chalk line on both sides of the ridge to produce
baffle alignment. Place vent sections centered over the slot using a chalk line. Place
nails at pre-marked locations on top of the vent.Nails shall be minimum 11 guage 1 3/4"
corrosion resistant smooth shank roofing nails, a minimum 3/16"penetration into wood
substrate is required.
Ridge Shingle: Using nail lines provided on top of vent. Nail cap shingles in place,as per ridge cap
shingle manufacturer's installation instructions.Nails shall be minimum 11 gauge l-'/4"
corrosion resistant smooth shank roofing nails,a minimum 3/16"penetration into wood
substrate is required.
Ventilation Calculations: Refer to manufacturer's published literature
LIMITATIONS:
1. Refer to applicable Building Code required ventilation.
2. Ridge Vent shall comply with applicable Building Code.
3. Ridge Vent shall not be installed on rof mean heights greater than 33 feet.
NOA No.: 14-1022.10
MIAMMADECOUNTY Expiration Date: 11/01/17
Approval Date: 01/29/15
Page 3 of 4
DETAIL A
20'Length
a
i
B❑TT❑M VIEW
T❑P (VIEW
11.5"Wide T'
END VIEW
END OF THIS ACCEPTANCE
NOA No.: 14-1022.10
MIAMI-DADE COUNTY Expiration Date: 11/01/17
Approval Date: 01/29/15
Page 4 of 4