HomeMy WebLinkAboutProduct Approval (3) MAW Mg. MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORYrC OF OURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATIO �gISN Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Cobra®Ridge Runnefrm Exhaust Vent for Roof Ridge LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA#13-0604.06 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. l NOA No.: 14-1022.10 MIAMIMADE COUNTY � �'�� Expiration Date: 11/01/17 �FgjyasynApproval Date: 01/29/15 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Ventilation Material: Plastic Minimum Slope: 3:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Product Dimensions Test Product Specification Description GAF Cobra®Ridge 20' Length(Roll) TAS 100 Low profile attic ridge vent in roll form for Runnefrm Exhaust 11.5"Width installation under ridge shingles. Vent for Roof Ridge .7"Height MANUFACTURING LOCATION 1. Cumming,GA. EVIDENCE SUBMITTED Test Agency/Identifier Name Report Date ETC Laboratories,Inc. ASTM D 1929 ETC-07-718-19959.0 09/27/07 ASTM D635 ETC-07-718-19959.0 09/27/07 ASTM D 2843 ETC-07-718-19959.0 09/27/07 PRI Construction Materials Technologies,Inc. ASTM G 26 GAF-138-02-06 02/09/07 TAS 100(A) GAF-138-02-04 02/09/07 TAS 100(A) GAF-439-02-01 05/21/13 NOA No.: 14-1022.10 MIAWDADE COUNTY Expiration Date: 11/01/17 Approval Date: 01/29/15 Page 2 of 4 APPROVED APPLICATIONS Tradename: GAF Cobrao Ridge RunnerTM Exhaust Vent for Roof Ridge System Type: Mechanical attachment of ridge vent. Slot: Determine whether the rafters are truss or ridgepole construction. Chalk a cut line of each side of ridge. Cut a 1 3/4" (no ridge board) or 31/4"(ridge board)maximum slot along the apex of the roof by cutting 7/8" (no ridge board)or 15/8"(ridge board)on each side of the ridge. The slot shall terminate 1 foot shorter at each end than the total length of ridge vent used. Installation: Place,center and conform the end of a piece of ridge vent at each end of slots. Mark the location of the end of the baffle. Strike a chalk line on both sides of the ridge to produce baffle alignment. Place vent sections centered over the slot using a chalk line. Place nails at pre-marked locations on top of the vent.Nails shall be minimum 11 guage 1 3/4" corrosion resistant smooth shank roofing nails, a minimum 3/16"penetration into wood substrate is required. Ridge Shingle: Using nail lines provided on top of vent. Nail cap shingles in place,as per ridge cap shingle manufacturer's installation instructions.Nails shall be minimum 11 gauge l-'/4" corrosion resistant smooth shank roofing nails,a minimum 3/16"penetration into wood substrate is required. Ventilation Calculations: Refer to manufacturer's published literature LIMITATIONS: 1. Refer to applicable Building Code required ventilation. 2. Ridge Vent shall comply with applicable Building Code. 3. Ridge Vent shall not be installed on rof mean heights greater than 33 feet. NOA No.: 14-1022.10 MIAMMADECOUNTY Expiration Date: 11/01/17 Approval Date: 01/29/15 Page 3 of 4 DETAIL A 20'Length a i B❑TT❑M VIEW T❑P (VIEW 11.5"Wide T' END VIEW END OF THIS ACCEPTANCE NOA No.: 14-1022.10 MIAMI-DADE COUNTY Expiration Date: 11/01/17 Approval Date: 01/29/15 Page 4 of 4