HomeMy WebLinkAboutProduct Approval BCIS Home Log In �I User Registration Hot Topics Submit Surcharge j Stats&Facts j Publications C FBc Staff BCIS Site Map Links j Search Plarlda WIN 3 Product Approval + y ! USER:Public User _ z*trztx 1 Product Approval Menu>Product or Application Search>Application List>Application Detail Z, '� .. g * s FL# Fl-15213-112 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Cl Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com 'i Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received it Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King,P.E. I E Validation Checklist-Hardcopy Received Certificate of Independence FL15213 R2 COI CERTIFICATE of INDEPENDENCE.Ddf Referenced Standard and Year(of Standard) Standard Year 101/I.S.2 1997 101/I.S.2/NAFS 2002 AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E1866 2002 ASTM E1996 2002 ASTM E330 2002 TAS 201,202,203 1994 'I I 11 I i Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/28/2015 Date Validated 04/29/2015 Date Pending FBC Approval 05/07/2015 Date Approved 06/23/2015 Summary of Products Go to Page Page 1/2 I FL# Model,Number or Name Description 15213.1 a.Smooth/Wood Grain/White Wood_ 6'8"I p clam Op Tu Qb�g1r lass Si gle or- Grain/Rustic/Mahogany Series Inswing/Outswi 'Q fguration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R2 II Inst 15213.1.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports I Other:See INST 15213.1 for Design Pressure Ratings,any FL15213 R2 AE Eval 15213.1.odf additional use limitations,installation instructions and Created by Independent•Third Party:Yes product particulars. 15213.2 b.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing(OX or XO Fiberglass Door -Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R2 II Inst 15213.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15213.2 for Design Pressure Ratings,any FL15213 R2 AE Eval 15213.2.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15213.3 c.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing(OXO- Fiberglass Door Configuration) ' I i Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R2 II Inst 15213.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15213.3 for Design Pressure Ratings,any FLIS213 R2 AE Eval 15213.3.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15213.4 d.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing,'-Inswing/Outswing(OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R2 II Inst 15213.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports I Other:See INST 15213.4 for Design Pressure Ratings,any FL15213 R2 AE Eva] 15213.4.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15213.5 e.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing-Inswing/Outswing(OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R2 II Inst 15213.5.odf plastprow 8; E--- 5200 =�z M W. CENTURY BLVD. LOS ANGELES CA 90045 .�Y'•.•...,,,,,.. g.`� 1 H 37.50^MAX.O.A. �� o> m FRAME WIDTH � '���/ *Rf\```�. o r�m z !lflll i a N•� Smooth/Wood Grain-/White Wood Grain Rustic/Mahogany Cha a N a a Series Fiberglass Door a Oz INSWING/OUTSWING ° R: "IMPACT" ~s Sr z$ o GENERAL NOTES CL 1. This product has been evaluated and is In compliance with the 5th Edition o a X o �? (2014)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). ,m 2• Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact N resistant covering.This product meets missile level"Wand includes Wind Zone 4 z as defined in ASTM El and Section 1609.1.2,2 of the FBC. O c 0 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. I? k' 5. Site conditions that deviate from the details of this drawing require further 3 ii engineering analysis by a licensed engineer or registered architect. a � c TABLE OF CONIM o SHEETN DESCRIPfiON 'z m +r OVERALL ' :pESiGN PR�55URE(P�i'' o 1 DLyp..r i elevation,des n pressures,&general notes are 02/16/12 z �541(ING FRAME 2 DoarporeldetaTs sale N.T.S. 4 DIMENSION _POStifVE., NEGATIVE;' ; 3 HorizontalcPansections DWO.en JK m ` 4 Vertical cross sections INSWING 37.50"x 82.00" +65.0 -70.0 OW.BY. LFS } 5 Buck and frame anchoring-1X buck mason eonstruction d s 6 Frame—anchoring-IXbuckmasonry cordiruction owFL-15 ry OUTSWING 37.50"x80.37^ +65.0 -65.0 FL-15213.1 7 Bill of materials&components ° sxaT i ov 7 d RNClienh\Plastpro.NCPERMANDW%RDrida Fmduct.ApptoWSXH.-1S213\C-Drawings%Ot ntlFL-15213.1-.Bdwg,21 79.25 MAX.DOOR PANEL HEIGHT N A o O P0 A )( N N 000 N IM: ITI a uy b Teo a z 0 I� I� I m 3 No Q v N N a .o —Ij o om m a 3w N N ti A A A O A O INN v a o • T n z ```Tpu n Up,4 ��.� v.•ucFaisF.,A .� N.43409 e /rte $ S PRODUCT; Document.Prepanni By.-, �N cn c N FIBERGLASS INC. P�nF- No.ndon F43409 ttlt '''' �D PART OR ASSEMBLY: }I-��/!BUILDING CONSULTANTS. INC, 1 ---7227's LIPOATE TO 5TH ED.(2014)FBC JK VY P.O. Box 230.VatAco.FL 33595 N NO DATE EIy ODOR PANEL DETAILS Phone Nos 813.659.9197 REVISIONS FBPE CA No.9813 0 MCI a R.W.I311rtax+a C.ReutT—Ira.. 1-114 MIN. ��```, •* //��i EMB.(TYP.) 4 4 :�-0; m 2 4 12 23 4 =Vi * � gid". 30 . . 'I���., y�`� o m m ° III •'•.....• P• ��� z o-m 'a IIS//iniii� � z° 16 _ -- --_ - v Fo-9mW. - v 40 INTERIOR 3 v 3 � $c, 'mCia CSL " 0 3 z 3 OL 16a ° 17 �h/ z G O W 32 31 EXTERIOR �� y B 21 �Sm ER m 3 HORIZONTAL CROSS SECTION 3 shownw/ix sub-buck 3 4 o a y 1-i/4"MIN. 4 4 1-1/4"MIN. _ EMB.(TYP,) EMB.(TYP.) a a 5 4 0.15' 0.1s' 3 CSINK 'm >° 5 CSINK (TVP.) In P•I 6 •� ' ° 12 23 ` e $ 23 12 N En 6 Z W EnO 16 6 lx 40 INTERIOR INTERIOR 16 z R g zz w ;4 o Date 02116112 ° EXTERIOR EXTERIOR 13a scALL, N.T.S. 9 3 8 21 4U 27 4 1 MG.By, JK m cxK BY: LFS 3 s 1 2 HORIZONTAL CROSS SECTION r�HORIZONTAL CROSS SECTION MY=NO,; d 3 Oulsving shown-inswing 3 Outswing shown-inswing FL-15213.1 5 also approved also approved a b sxtcr 3 er L Rialants\Plastpm,Inc PERMANENT\Rorida Pmdud Appmes\FL-15213\C-Dr3win9s\Cua AFL-15213!-Adwg,4.1 7rt5] N • A I{IIm A A W 1� O Om ma • ° vin - < C 0 O y y T _ •P O. sd • W N O.1Jm • C SINK J L (TYP.] 1-114"MIN. EMB.PYP.) HCn AN W A C2 C2 AA. - � �p . •n m XT O U3 n cr mn Ha O y y = m m ° O a° e 0 ITO A W N ems' e A 1-114"MIN. EMB.(IYP.J 00l, I'll Hfy No.43409 PRODUCT: Doeu—t. P.Pared w--, IEE' F Fi Lyndon F.Sehmldt �i� OR19� 'G�`� 1 N z ro 48= DOOR P,I- No. 43409 ��ii��,�01VAL1 % PART OR ASSEMBLY: �Kq�/BUILDING CONSULTANTS, INC. L z�n 1 Date 1s UPDATE To 5TH ED. 2014)FBC JK VER77CAL CROSS BECKONS d IiUU P•0. Box 230,valNw, FL 33SSS I N NO DATE BY Phone No.-. 613.859.9197 REVISIONS FBPE CA No. 9813 021212 R.W.BDIWINa CONBNLSANTD)Na. Ct a: 4" �yter� g �'" `dro ,.� • � 4• �N•:7 z° 41 – – – – V�j zW v t_+ � e � TYP.HEAD&JAMBS 2X7 J� fl o m a o`.� BUCK E oz - e o w – a TYP:HEAD& S.:a z F ;b JAMBS _ o 2" 2j BL r, re UCK Iq FRAME z$ z I a m Ljo MASONRY MASONRY OPENING o Z OPENING w U" N 2 _ O o $ mm a a LWe •a � Z u BUCK ANCHORING HINGEJAMB FRAME ANCHORING STRIKEJAMB 8 N Masonry 2X buck construction " CONCRETE ANCHOR NOTES: 1.Concrete anchor locations at the comers may be adjusted to maintain the min. Q edge distance to morfor)oints. 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to $ maintain the min.edge distance to mortorJolnts additional concrete anchors 21 t M13 ? may be required to ensure the AX.ON CENTER"dimension are not exceeded. 3 Concrete anchor table: 31 P MIN CLEARANCE MIN CLEARANCE a ANCHOR ANCHOfi MIN TO MASONRY y TO ALSJACEMu <lYPE SIZE EMBEDMENT 8 27 z n . . ,EDGE '::ANCHOR 5T3' —02116112 i 1NV ® " 1.1/4" 2 4 Ste: N.T.S. 9 TAPCON ELCO 1/4" 1.1/b" 1" 4" rnm.sr JK m ULTRACON cNK.m; LFS 3 WOOD SCREWINSTALIATIONNOTES: HINGE JAMB STRIKEPWTEDE►AIL ¢ 017p4nNC NO.: Q I.Maintain a minimum 5/B"edge distance,1"end distance,&1"o.c,spacing of FL-15213.1 N wood screws to prevent the splitting of wood. s m N O do I In A. —L• �N�;7 z �t O� 'm, Qj >_ W�..I'll ............ ellp to o a,o 30 14 :�a bxZ* Za TYP.HEAD& _ m N g o g m c w m JAMBS \ 5 �1 m e a v 1X5 BUCK gE ao`Z w _ 8 _r a n z FRAME 8 VO (YZ MASONRY w wo OPENING �r z gad _ O c co � o � m v' N HINGEJAMB FRAME ANCHORING STRIKEJAMB o a Masonry 1X buck construction u' ^' CONCRETE ANCHOR NOTES: n I 1.Concrete anchor locations at the comers may be adjusted to maintain the min, Q edge distance to mortar joints. 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to $ maintain the min.edge distance to mortar Joints,additional canasta anchors 3 Concree a u $ may rto to ensure the MAX.ON CENTER"dimenslon are not exceeded. E - te anchor table., 21 32 26 w 3 -- "vMIN CLEARANCE MSN CLEARANCE �- AIyCJLOR ANCHOR MIN 31 NR0 ; TO MASpY TO ADJACENT;':', TYPE SIZE @{VIBEDMENi fOGt i . . . ' .?iANCNbR • ' 8 27 _ o a' O TANo 1/4" 1-1/4" 2"ELCO 4° 33 wTe 02116112 °z UL RACONd 1/4" 1-1/4" 1" 4" s=L- N,T.S. if s ® $Ile 1.1/T 3" owc V: JK m ¢ T PCON INGEJAMB STRIKE PLATE DETAIL cns•nn LFS WOOD SCREW INSTALLATION NOTES: MAW=Z. I.Maintain a minimum 5/8"edge distance,?"end distance,&1'o.c.spacing of FL-15213.1 N wood screws to prevent the spliUing of wood. N GSVIE[r 6—7 7-1 a'r' eluoPMATERIALS o� ITEM DESCRIPTIOM MATERIAL 41 1 MASONRY-3,000 PSI MIN.CONCRETE.CONFORMING TO ACI CONCRETE • ' * o J=2 LL 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 2 1XBUCKSG>=0.55 WOOD W:? 3 2X BUCK SG>=0.55 WOOD 0,.,Y.."... .•••4 IX 5 1/4'X�/4 PF1H E CO OR ITW CONCRETE SCREW STEEL ,SPACE ,'��J��1►*-`�t\! ```` $V:2 - Rm- X•• EHiW00D=- EW m 2�< _ - ffi #9 x 3/4"PFH WOODSCREW=- _ — STEEL- 9 DOOR SKIN MIN.0.076'THICK FIBERGLASSIE ^1 --�{� � r mdT 4.56" 456" 10 INSWING VINYL DOOR BOTTOM SWEEP BY ENDURA VINYL `� I . 10A VINYL DOOR BOTTOM SWEEP#3628 BY HOLM IND. VINYL ° 11 REINFORCEMENT WOOD FOR LOCK WOOD rDt 12 FINGER JOINTED PINE JAMB WOOD D E r13h:#9-x-2.114'PFHY�QQD'SCR 'SI>ELS-� --21T -� 2.tT'---�� 14 BOTTOM RAIL _ CELLULAR PVC 15 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM.—/WOOD 2.a 2.43 o gy 15A INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM./WOOD z o 16 FORCE 5 WEATHER STRIPPING BY ENDURA FOAM 12 JAMB 29 OLYF19 J Me o 0 16A COMPRESSION WEATHER STRIP QLON 650 BY SCHLEGEL FOAM n �� i R 17 KWIKSET KEYED ENTRY SIGNATURE SERIES STEEL w ocoi 18 KWIKSET DEADBOLT-SIGNATURE SERIES 780 STEEL a� Hyl 20 POLYURETHANE FOAM BY NANYA POLYURETHANE O 21 4"x 4'BUTT HINGE STEEL 23 POLY FIBER JAMB COMP./VINYL 24 HINGE&LATCH STILE CELLULAR PVC ,�r 25 TOP RAIL CELLULAR PVC 4.59 4.56' 'm 26 DEADBOLT STRIKE PLATE STEEL 27 LATCH STRIKE PLATE STEEL 28 OUTSWING BUMP THRESHOLD ALUM./WOOD Y 29 HINGE&LATCH STILE;REINFORCEMENT 30 114'X 334'/ PFH ITW CONCRETE SCREW STEEL z 31 #9 X i"PFH WOOD SCREW STEEL G 32 1!4"x3.1/4'PFHITW CONCRETE SCREW STEEL 33 3/16'X3-14'PFHITWCONCRETESCREW STEELyADJUSTARIEINSWINGSIII �ZOIRSWINGBUMPTHRESHOLD Q 40 1 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS � z s 5 5.62' a i � 'z v atE= 02116112 i scut N.T.s. ° DWO.sr: JK m' cm Dn LFS 3 (;�ADJfI ABLE INS INGSIII D FLG 15213.1 ro 0 SHEET 7 Of 7 W