Loading...
HomeMy WebLinkAboutProduct Approval MIAMI C1111bE MIAMI-DADE('Ol_`NTl' PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami.Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) �c�r«.mia�nidadc.gov/ncra GAF Materials Corp. Alps Wayne, 07yne, NJ 07470 / l•�' SCOPE: This NOA is being issued under the applicable rales and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County PERA- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline"`Prestique 30,Timberline`,HD,Timberline`",Natural Shadow'", and Timberline'R American HarvestT"Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA#10-0720.10 and consists of pages 1 through CONTRACTOR COPY The submitted documentation was reviewed by Alex Tigera. NOA No.: 11-1122.04 MIAMI•DADECOU� Expiration Date: 02/21/17 Approval Date: 02/09/12 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials Laminate Deck Type: Wood SCOPE This approves GAF Timberline Prestique 30, Timberline*HD, Timberline*Natural Shadow ,and Timberline* American Harvest" Shingles as manufactured by GAF Materials Corp described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline"'Prestique 30 13'/4"x 393/g TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle, with a laminate profile Locations#1,2,3,4,5,6,7,8 GAF Timberline"' HD 13'/4*'x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt Alaniflacturing roof shingle,with a laminate profile Locations#1,2,3,4,5,6,7,8 GAIT Timberline* Natural 13'/4"x 393/g TAS 110 Fiberglass reinforced heavy weight asphalt Shadow"" roof shingle, with a laminate profile Manufacturing Locations#1,2,3,4,5, 6,7,8 GAIT Timberline"American 13'/4"x 393/ TAS 110 Fiberglass reinforced heavy weight asphalt Harvest"' roof shingle, with a laminate profile Manufacturing Locations#2,9 only MANUFACTURING LOCATION 1. Tarnpa, FL 2, Michigan City, IN 3. Mobile, AL 4. Baltimore, MD 5. Myerstown, PA 6. Ennis, TX 7. Tuscaloosa, AL 8. Dallas, TX 9. Fontana, CA. CONTRACTOR COPY NOA No.: 11-1122.04 MIAMI-DAD,COUNTY Expiration Date: 02/21/17 Approval Date:02/09/12 Page 2 of 6 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. ASTM D3462 I I CA48924 10/24/11 Underwriters Laboratories, Inc ASTM D3462 I OCA21994 04/22/1 1 Underwriters Laboratories, Inc ASTM D3462 I OCA28717 07/26/11 Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories. Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NKOS 159 08/09/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories, Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories, Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories. Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories. Inc. TAS 107 05CA42840 1 1/1 1/05 Underwriters Laboratories. Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories. Inc. TAS 107 03)CA3)5209 10/17/03 Underwriters Laboratories, Inc. TAS 107 04CAI3850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 1 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 913-72 of the Florida Administrative Code. CONTRACTOR COPW CMIAMUDADE COUNTY=TY NOA No.: 11-1122.04 Expiration Date:02/21/17 Approval Date:02/09/12 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Rooting Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING 1. Shingles shall be labeled with the Miami-Dade Seal as seen below,or the wording"Miami-Dade County Product Control Approved". ■ MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: LI This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. CONTRACTOR COPY NOA No.: 11-1122.04 MIAMI•DADECOUNTY Expiration Date: 02/21/17 Approval Date: 02/09/12 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17" OFF 4th 11 OFF 3rd 6" OFF 2nd FULL 1 st CUNTRACTOR CON WMIAMUDADECOUNTY NOA No.: 11-1122.04 Expiration Date:02/21/17 Approval Date:02/09/12 Page 5 of 6 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/8" Release Tape 7— 131 1" 811,274 5-5/8" Front Side (Maximum Slope 12:12) 39-3/8" Release Tape ers2„ 71„ 1„ , 4 6" 5-5/8" Front Side (Maximum Slope 21:12) Tab Sealant 1 2„ 3/8„ 1/2" Back Side END OF THIS ACCEPTANCE CONTRACTOR COPY MIAMI•DADECOUNTY NOA No.: 11-1122.04 � Expiration Date: 02/21/17 Approval Date: 02/09/12 Page 6 of 6