Loading...
HomeMy WebLinkAboutProduct Approval sti SCIS Home j Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications1 FBC.Staff 1 SCIS Site Map.i Links Search j i;OIlt�2 .. 4I,< Product Approval < USER:Public User 1l��,- --�HF pppr s PrOduct Approval 4S nu>Pgi duct or ApPhcatlomScarch>Qpnhcat',on Cisi>Application Detail L(�moi• ',i.=I�r FL# FL16048-R3 ��� ��� Application Type Revision Code Version 2014 PERMIT fI;LlC Application Status Approved St. Lucie County, FL Comments Archived 4 Product Manufacturer TRI-BUILT Roofing Products Address/Phone/Email 9050 Louisiana Street Merrillville,IN 46410 (201)842-2449 david.ruiz@trlbuiltmaterlaisgroup.com Authorized Signature David Ruiz david.ruiz@trib6i.l.tmaterialsgroup.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford,N7 07073 (201)842-2449 david.ruit@tribuiltmateriaisgroup.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance-.Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received, Florida Engineer or Architect Name who developed' Robert,Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLc Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W.Knezevich,PE Ell Validation Checklist-Hardcopy Received Certificate of Independence FL16048 R3 COI 2015 01 COI Nieminen.odF Referenced Standard and Year(of Standard) Standard Year ASPM D1970 2009 ASTM G15S 2005 FRSA/TRI April 2012(04-12) 2012 TAS 103 1995' Equivalence of Product Standards Certified By Sections from the Code, Product Approval Method Method 1 Option D Date Submitted. 10/08/2015 Date.Validated 10/19/2015 Date.Pending,FBC Approval 10/21/2015 Date Approved 12/15)2015 Date Revised 10/06/2016 Summary of.Products FL# Model,Number or Name Description 16048.1 TRI-BUILT Roof Unde.rlayments Self-adhering,modified bitumen roof underlayments Limits of Use- Installation Instructions Approved for use in HVHZ:No FL16048 R3 I1'2015 10 FINAL ER TRI- Approved for use outside HVHZrYes BUILT UNDERLAYMENTS FL16048-113.Ddf Impact,Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:+N/A/-45 Created by Independent Third Party:Yes Other:.1.)The design pressure noted herein pertains to use. Evaluation Reports of foam-on the systems overtop the self-adhering FI I6646 R3 AE 2015 '10 FINAL ER TRI- underlayment for one particular application.See ER Section BUILT UNDERLAYMFNrs FLI6048-113 Ddf 5.6 for details.2.)"Refer to ER'Section 5 for other Limits of Created by Independent Third Party:Yes Use. Back NeM Contact Us:i 2601 Blair Stone Road.Tallahassee Fl,32399 Phone:85"87-1824 The State oRFlorida is an AA/rfo employer.coodrioht 2007-2013 State of Florida,:.Privacy Statement is Ai_e -,birhy statement::Refund Statement Under Florida law,.email addresses are public records.If you do not want your a-mal address released in response to apublic-records reeiuest,do not send electronic mailto this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for o09cial communication with the licensee..However email addresses am public record.If you.do not wish to supply a personal address, please.provide the-Departmentwith an email address which can be made available to the.pubiic.To determine if you are a licensee under Chapter 455,F.S.,please dick hem. Product Approval Accepts. G M-RE M Credit`Card Safe EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 MD 353 CHRISTIAN STREET; EET,UNIT#13 TRINITY OXFORD,CT 06478 PHONE:(203)262-9245 EVALUATION REPORT FAX:(203)262-9243 Allied Building Products Corp. Evaluation Report A42960.10.12-113 dba TRI-BUILT Roofing Products FL16048-R3 9050 Louisiana Street Date of issuance:10/25/2®12 Merrillville,IN 46410 Revision 3: 10/08/2015 SCOPE: This Evaluation Report-is issued under Rule 61G20-3:and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5'h Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This.Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation Changes,or provisions of the Code that relate.to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrInityl FRO requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrInitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION.Upon request,a-copy of this entireEvaluation Report shall be,provided to the user-by the manufacturer or its distributors and shall be.available for inspection at the job site at the request of the Building 0.fficial. This Evaluation Report consists of pages 1 through 5. Prepared by: "Ok .......... ........... /I............... Robert J.M.Nierninen,P.E. The facs'llmle seal appearing vm authorized by Robert Nierninen, P.F-w 10/(*/2915.TPisd�notsemeasaneleczmn-icailysuvmd Florida Registration No.59166,Florida DCA ANE1.983 document.Signed,sealed hardoopies have been transmitted to the CERTIFICATION OF INDEPENDENCE: Product Approval Administrator and to the named client 1. -TrinitVIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not ownedi,operated or controlled by any company rnanufactUrin1g or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nleminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process-of the product. S. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen,P.E.are, in anyway,the Designer of Record for any project.on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that-purpose. i2 ' l��i�ll � ER® j ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated.compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject fo the Installation Requirements.and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2:4,1507.2.8;1507.2.9.2, Physical Properties ASTM D1970 2009 1507.4.5.1,1507.5.3,lSd7.7.3 1504.6' Accelerated Weathering ASTM.G155 2005 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties S40540.11.13 11/19/2013 ERD(TST6049) Physical Properties 540540.0 3.14 03/26/2014 ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014 ERD(TST6049) Physical.Properties 544870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties 544870.04.144 04/10/2014 ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties 543530.02.14-1-111 05/14/2014 ERD(TST6049) Physical Properties 543530.05.14 05/28/2014 ERD(TST(5049) Physical Properties 540540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13%2015 ERD.(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 09/04/2015 UL,LLC..(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Self=Adhering Underlayments: 4.1.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 364nch sheet width. 4.1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment 4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering,.,glass-mat reinforced,film-surfaced,SBS modified bitumen roof underlayment: I LIMITATIONS; 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nie'rninen, P.E. are, in any way, the Designer of Record for any-project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC; Evaluation Report A42960.10.12-R3 Certrjlmre ojAutharfiarlon A9503 171.16048-R.3 Revision 3:10/08/2015 Page 2 of S ( 1 J TRINITY i ERD 1 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within PBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are as follows: TABLE 1 ROOF DOVER OPTIONS Asphalt Wood Shakes Underlayment Nail-On Tile Foam-On Tile Metal Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri-Built_S/A HTTU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam-On Tile" is limited to use of the following Approved Mile adhesives unless tensile adhesion/ long term aging data from an accredited testing laboratory is provided. ➢ Tri-Built S/A HTTU Underlayment with 3MTm 2-Component Roof Tile Adhesive AH-160(FL6332)or Dow TileBondl Roof Tile Adhesive(FL717) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment, TrkBuilt S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; ASTM D41 primed structural concrete. While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self- adhering.underlayment. 5.6.2 Bond-to-Insulation: Tri-Built S/A HT TU Underlayment applied to: Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam:-on the systems;insulation attachment shall be designed by a qualified-design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. 5.6.3 Bond to Mechanically Attached Base Layer: ➢ ASTM D226,Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified-requirements. For installations under foam-on tile systems,base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-12). Exterior Research and oesign,LLC. Evaluation Report A42960.10.12-113 Certftute ofAuthariza tion 09503 F1.16048-113 Revision 3:10/08/2015 Page 3 of 5 TRINI-rY i ERD 5.6.4 Wind Resistance for Underlayment Systems-in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems.beneath foam-on tile systems,where the underlayment-forms part of the load-path. The follow_ing.wind uplift"limitations apply to direct-deck underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure' is the result of testing for wind load resistance based on allowable wind loads, and reflects the.ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 16.09 for determination of design wind pressures. 5.6.4.1 Maximum Design Pressure=-45.0 psf. Deck: Min.15/32=inch plywood to meet project requirements to satisfaction ofAH1. Primer: (Optional)ASTM D41 Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.7 Exposure Limitations: 5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than30-days after installation 5.7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180=days after installation. 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation requirements subject to the Limitations set forth in Section-5 herein and the-specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debrisprior to application,and prime the substrate(if applicable). 6.3 Tri-Built-Sand-11 SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering,to be installed. 6.3.2 Non-Tile applications: While priming is optional,TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation.within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and-unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally wiil.e holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12,-Allied Building Products Corp recommends back-nailing in the overlap,area at-the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley.or ridge. Drape.and press sheet into place, working from the.center of the valley or ridge in each direction. For valleys,apply the sheet starting at the,lowest point and work upward. 6.3.3 Tile:Applications(Tri-Built S/A HT TU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R3 Certificate of Authorization 119503 FL16048-113 Revision 3:10/08/2015 Page.4 of 5 C.10 ®f 1111 ERS 7. BUILDING PERMIT,RECQUIREMENTS; As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the.installation of this product. S. MANUFACTURING PLANTS: Contact,the noted QA agency for information on product locations covered for F.A.C.Aule.9k-3 QA requirements. 9. QUALITY.ASspRANCE BMTY: UL,.LLC—QUA9625;(314)578-3406;r,k.chanceilor@us.ulcom END OF EVALUATION REPORT FictenorResearch and Design,ik Evaivation Report A42960.iom-R3 Ceroft cote of.Authcdzctron#9503 FL16048-R3' Revision 3:10/08/1015 Page 5 of 5'