HomeMy WebLinkAboutProduct Approval IPA 00AWW"cot lit -
Wwss sNofesmopall
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publicatlons I FBC Staff I BCIS Site Map I Links In Search
Florida
" 'Product Approval
r �j_-` USER:Public User
® Product Approval Menu>Product or Apolication Search>Application List>Application Detail
• "�� FL# FL1956-R12
Application Type Editorial Change
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvalsiby DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
I
Comments
Archived
I
i
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri—eden@tamko.com
i
Authorized Signature Kerri Eden I
kerri—eden@tamko.com
I
I ,
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
ke rri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing j
Subcategory Asphalt Shingles
i
i u
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By Robert J. M. Nieminen, PE
J': Validation Checklist- Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
I '
,V
I
I
I.
� a
d
October 11,2012 1
I
Tamko Building Products Inc
Ms.Kerri Eden $
220 W 4th St j
PO Box 1404
Joplin,MO 64801
I
I ,0
RE: TAMKO Shingles
Dear Ms.Eden:
This is to confirm that the attached shingle matrix pertains to Tamko produced shingles.
I
All the products have been tested and meet the criteria for the standards mentioned. They are covered by
UL's Follow-Up Service Program under Tamko's File R2919.
The Listing Mark of Underwriters Laboratories Inc. on the product is the olnly method provided by UL to
identify products manufactured under its Listing and Follow-Up Service.
Combination Listing/Classification Mark—A Listing Mark combined with a Classification Mark is
provided on products that have additionally been investigated in accordance with various supplemental
standards. Please refer to the labels on the product.
Should you have any questions,please feel free to contact the writer.
II
Very truly yours, Reviewed By:
William G Marshall(Ext.42735) Alpesh Patel (Ext. 42522)
Sr. Engineering Associate StaffEngineer
Fire Protection Division 3019A Fire Protection Division 3019A
I `
i
i
I '
I
I' '
UL
T".R- 0 Shingle Matrix
P'hila ip-nhu-g, P.S• Excieri i, Im
Pmduet 3faue ABUT ABI14 AM T5; .ASTEE C51A g'raduet P172M ASM ASM-1 AS 2-r, 'Hl R9Tr.5 CSP.
DM2 051,61 D€291 MG B7159 129.5 D2452 D2181 DE-281 2296 87159 122.5
Class C122a Class Mass Clazz Mass Mass Clasz
T< $ H $ If H H H
Glass-S-eal ,[RR] glass-Seal (AR] X X X X X
Elite Glass-Seal EAR) Elite Glazz-.Seal (ART X X X X X
Heritage X X X X X X Heritage X X F. X X X
Heritage SD EAR], X X X. X X X Heritage 20 [MR) X X X X X X
Heritage Xl JARI, Heritage XZ EAR) X X - -
Heritage Wo dgafe X 'ad - - -
Heritage •50 (ART X X X X X X Heritage 59 EAR) X X X X X X
Heritage Premium X X X X X X Heritage Premium X X X X X X
Heritage 'vantage [ART X X X X X X Heritage 73atage •(AR)
Heritage vin+aage ? °� ---- ---- ---- 1-2-114 X 22 Hip and Ridge X X ---- --- ----
12 f 112 Hip .and, Ridge
Dallas, TX Puscal a0za, All
Praduat gaze ASTM ASIN ASTM UI ASTH CSS, NL Pra3uet Name A3,71-1 ASTM ROM Irl ATbt CA
D2462 D9152 DES91 MD 0159 128.5 2218 MEM B2161 B62BI 12399 D^159 122.5
Class Class Cla-5s Class Class Clazz +Class Class
H H $ H E H H H
Mass-seal [AR) Glass-Seal (ARI' X X X X X
Elite Glass-Seal (AR) Elite Glass-Sea'! [ARTS X X X X X
Heritage X X X X X X Heritage X X X X X X
Heritage 80, .[ARI X X X X X X Heritage 39 (AR) X X X X X X
Here 'rH (ARI X- X - X— X—X----
- ---- -.$zritagn Wmdgate --- X- _X X-- X _ - X
Heritage 50 (ARI X X X X X X Heritage 5Q ini X X X X X X
Heritage Premium X X X X X X Heritage Pieanium X X X X X X
Heritage Vintage (:Ap Heritage Tiatage (_RT
Heritage IR i, :: X a> K X ., 12 X 12 Hip and Ridge X X ---- ---- ----
UL
Praduct Mame ASYM D3462 A=, D3161 ASTM D63SI UL 2399 A-M4 D7153 CSA
'Class F 'Class .H Class H Class H 123.5
Glass-Seal (AR) X - X X
Elite Glass-Seal (AR3 X X X X X
Heritage X X X X X X
Heritage 30 (AR) X X X X X X
Heritage XL (PR)
Heritage S 0 (AR)
Heritage Premium
Heritage Vintage (AR)
12 X 22 Hip and Ridge X X --- ---- ---
I2-1/4 x 12 Hip & Ridge K X
I ' ,
UL
September 17,2015
Tamko Building Products
220 W 4th Street
PO Box 1404
Joplin, MO 64801
Contact Name: Kerri Eden
Email Address: Kerd Eden(a)tamko.com
Subject: UL Third Party Inspection Service for Florida Quality Assurance
Expiration Date: September 17,2018
Reference: UL Order 10966260
II '
Dear Ms. Eden:
I �
This letter is to confirm that Tamko Building Products has an agreement with UL LLC to conduct
audits at your plant to verify Florida Quality Control requirements at the following locations:
Tamko Building Products Tamko Building Products Tamko Building Pryoducts
60' N.High St 1598 Hwy 183 2300 36"St
Joplin MO 64801 Phillipsburg KS 67661 Tuscaloosa AL 35401
Tamko Building Products Tamko Building Products
7910 S Central Expy 4500 Tamko Dr j
Dallas TX 75216 Frederick MD 21704 j
Quality Control System and Products will be inspected according to Florida Product Approval Report
FL1956 to ensure the manufacturer's quality documentation is well defined,fully documented and
effectively implemented.
I
A minimum of two(2)inspections per year will be conducted. This service has been,established
under file R2919.
i. .
UL LLC
333 Pfingsten Road,Northbrook,IL 60062-2096 USA
T:847.272.8800/F:847.272.8129/W:ULcom
i
j
I
Ifou have any y questions,please call me at 847-664-3623.
Kind regards,
I
I
i
LeAnna Gradecki
Project Coordinator
Product Safety
Tel:847-664-3623
Fax:847-513-7853
LeAn na.Gradecki(cD u l.com
----------------------=-------------
UL LLC
333 Pfingsten Road Northbrook,
IL 60062-2096 USA M:
847-664-3623
LeAnna.Gradecki@ul.com "
I
I ,
i
� I
I
i C ;
II ,
I,
i
I9
® SLITS GLASS-SEAL®
TAMKO GLASS-SEAL
BUILDING PRODUCTS 3-TAB ASPHALT SUINGLBS
Frederick, MD • Joplin, MO *Tuscaloosa,AL1,
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.'
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM'
FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESEINSTRUCTIONS WILL ADVERSELY
AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AMD CORNERS OF THE SHINGLES.
IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles.
1.ROOF BECK S.FASTENERS
These shingles are for application to roof decks consisting of NAILS: TAMKO recommends the use of nails as the preferred
plywood or sheathing boards capable of receiving and retaining method of application.
fasteners,and to inclines of not less than 2 in.per foot.For roofs WIND CAUTION: Extreme!wind velocities can damage these
having pitches 2 in. per foot to less than 4 in. per foot, refer to shingles after application when proper sealing of the shingles does
special instructions titled"Low Slope Application".For roofs having not occur. This can especiallybe a problem if the shingles are
pitches greater than 21 in.per foot,refer to special instructions titled applied in cooler months or in areas on the roof that do not receive
"Mansard Roof or Steep Slope Roof'.Shingles must be applied direct sunlight.These conditions may impede the sealing of the
properly.TAMKO assumes no responsibility for leaks or defects adhesive strips on the shingles.The inability to seal down may be
resulting from improper application,or failure to properly prepare compounded by prolonged cold weather conditions and/or blowing
the surface to be roofed over.
dust.In these situations,hand sealing of the shingles is required.To
insure immediate sealing,apply,4 quarter-sized dabs of TAM-PROD
NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, Premium SBS Adhesive or TAMKO Tam-Seal Adhesive on the back
dry and free from warped surfaces.It is recommended that metal of the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and
drip edges be installed at eaves and rakes. 1 in.(25mm)up from the bottom„of the shingle.Press shingle firmly
PLYWOOD:All plywood shall be exterior grade as defined by the into the adhesive.For maximum wind resistance along rakes,cement'
Engineered Wood Association.Plywood shall be a minimum of 3/8 shingles to the underlayment and each other in a 4 in.(102mm)width
of TAM-PRO SBS Adhesive orTAMKO Tam-Seal Adhesive.Caution:
in.thickness and applied in accordance with the recommendations Apply ONLY a thin uniform layer of adhesive less than 1/8 in.(3mm)j
of the Engineered Wood Association. thick.Excessive amounts can cause blistering of the shingles and C
SHEATHING BOARDS: Boards shall be well-seasoned tongue- may soften the asphalt in certain underlayments resulting in the
and-groove boards and not over 6 in.nominal width.Boards shall asphalt flowing,dripping and staining.Shingles must also be fastened
be a 1 in. nominal minimum thickness. Boards shall be properly according to the fastening instructions described below.
spaced and nailed. Correct placement of the fasteners is critical to the performance
of the shingle. If the fastener's are not placed as shown in the
Z.VENTILATION diagram and described below,this will result in the termination of
Inadequate ventilation of attic spaces can cause accumulation of TAMKO's liabilities under the Limited Warranty.TAMKO will not be
moisture in winter months and a build up of heat in the summer. responsible for damage to shingles caused by winds in excess of
the applicable mph as statedlin jhe Limited Warranty.See Limited
These conditions can lead to: Warranty for details.
1.Vapor Condensation FASTENING PATTERNS:Fasteners must be placed above or below
2.Buckling of shingles due to deck movement. the factory applied sealant in Ian area between 5-5/8 in.and 6-7/8
in.from the butt edge of the shingle.Fasteners should be located !
3.Rotting of wood members. horizontally according to the Idiagram below. Do not nail into the
4.Premature failure of roof. sealant.TAMKO recommends nailing below the sealant whenever
possible for greater wind resistance.
To insure adequate ventilation and circulation of air,place louvers 1)Standard Fastening Pattern.(For use on decks with slopes 2
of sufficient size high in the gable ends and/or install continuous in. per foot to 21 in.per foot)One fastener 1 in.back from each
ridge and soffit vents. FHA minimum property standards require end and one 12 in.back from each end of the shingle for a total
one square foot of net free ventilation area to each 150 square feet of 4 fasteners.(See Standard,Fastening Pattern illustrated below).
of space to be vented,or one square foot per 300 square feet if a NAILS
vapor barrier is installed on the warm side of the ceiling or if at least _ _V p. _
one half of the ventilation is provided near the ridge.If the ventilation
openings are screened,the total area should be doubled. Nailing - -- - 6-7/8”��''......__........_.__..............._......_..
IT IS PARTICULARLY IMPORTANT TO PROVIDE 1 5 WIT.
Area
ADEQUATE VENTILATION. 1
Butt Edge (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 12112
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1
1
i
�I
° (CONTINUED from page 1)
SLITS GLASS-SEAL®
TA
9:0MAMMAL
BUILDING PRODUCTS 3-TAB ASPHALT SHINGLES
Frederick, MD • Joplin, MO •Tuscaloosa,AL.
2) Mansard Fastening Pattern. (For use on decks with slopes 4.UNDERLAYMENT
greater than 21 in.per foot.)One fastener 1 in.back from each end UNDERLAYMENT: An and rlayment must be applied over the
and one fastener in.back from each end and one fastener entire deck before the installatiori of TAMKO shingles.Failure to add
13-1/2 in.back frommeach end for a total of 6 fastener per shingle. �
(See Mansard Fastening Pattern illustrated below.) underlayment can cause premature failure of the shingles which is'
not covered by TAMKO's Limited Warranty.
MANSARD FASTENING PATTERN Products which are acceptable for use as underlayment are:
NAILS
Asphalt Saturated Felt Underlayments:
TAMKO No.15 Asphalt Saturated Organic Felt
Nailing 6-7/8"
............ ..._.._......_ 5 5!8" • ASTM:non-perforated
aced I or a o asphalt organic
f organic felt
Area ..........._.........._........... �... Y
TAMKO Typ
non-perforated
'saturated o antc felt which meets'
rASTM D4869
Butt Edge Specialty Underlayments:
NAILS:TAMKO recommends the use of nails as the preferred method • Tam-Shield®Synthetic Underlayment
of application. Standard type roofing nails should be used. Nail • TAMKO TW Metal and Tile Underlayment,TW Underlayment
shanks should be made of minimum 12-gauge wire,and a minimum and Moisture Guard Plus® (additional ventilation may be
head diameter of 3/8 in.Nails should be long enough to penetrate required. Contact TAMKO's Technical Services Department
3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, for more information.)
the nails should be long enough to penetrate completely through
plywood decking and extend at least 1/8 in.through the roof deck. For Asphalt Saturated Felt Uriderfayments:
Drive nail head flush with the shingle surface. Apply the felt when the deck is dry.On roof decks with slopes I
4 in.per foot and greater apply the felt parallel to the eaves,
Properly Driven Improperly Driven lapping each course of the felt over the lower course at least
ojaW t!.&-t. underdd— o„e,d&Mn —ked 2 in.Where ends join,lap the felt 4 in.If left exposed,the felt
�-Asphalt may be adversely affected by moisture and weathering:Laying
sm.91.. of the felt and the shingle application must be done together.
�'r4°°mom For All Other Specialty Underiayments:
cbaight,good,teMh.U.n. inadNwte too doap,oda Inadnguato I
end g.sh with shmgt.cu d— P.n.t ag.n W.shingt. anchorage On roof decks with slopes,4 in. per foot and greater apply
the underlayment parallel to the eaves in accordance
with underlayment written application instructions. The
STAPLES:If staples are used in the attaching process,follow the underlayment should not be left exposed fora longer period of
above instructions for placement.All staples must be driven with time than is specified in the underlayments written application
pneumatic staplers.The staple must meet the following minimum instructions.The final roof covering must be installed before
dimensional requirements.Staples must be made from a minimum the structure is exposed1to adverse weather conditions,such
16 gauge galvanized wire.Crown width must be at least 15/16 in. as wind driven rain,high wind,hail,ice storms,etc.
(staple crown width is measured outside the legs).Leg length should
be a minimum of 1-1/4 in.for new construction and 1-112 in.for In areas where ice builds up along the eaves or a back-up of water
reroofing thus allowing a minimum deck penetration of 3/4 in.The from frozen or clogged gutters+is a potential problem,TAMKO's
crown of the staple must be parallel to the length of the shingle. Moisture Guard Plus®, TW Metal and Tile Underlayment:or TW
The staple crown should be driven flush with the shingle surface. Underlayment(or any specialty eaves flashing product) may be
Staples that are crooked,underdriven or overdriven are considered applied to eaves,rakes,ridges,valleys,around chimneys,skylights
improperly applied. or dormers to help preventlIwater damage. Contact TAMKO's
Properly Driven Improperly Driven Technical Services Departme i,t for more information.
°tel underdriven overdriven crooked Substitute products as shingle underlayment should not be used.
ANhalt
Shingles
�� rr mrc� Decking ,
CAUTION: DO NOT FASTEN INTO THE FACTORY APPLIED
ADHESIVE.
(Continued
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 12/12
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
t8mko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-88682
I
i
I .
® ELATE CLACS-SEAL® � (CONTINUED from page 2)
L1TLAMg0:] CLASS-STEAL
BUILDING PRODUCT'S 3-TAB ASPHA6T SHINGLES
Frederick, MD •Joplin, MO •Tuscaloosa,ALI
S.APPLICATION INSTRUCTIONS 8.BE-HOOFING
STARTER COURSE:A starter course may consist ofTAMKO Shingle Before re-roofing,be certain to inspect the roof decks.All plywood shall
Starter,self-sealing 3-tab shingles or a 9 inch wide strip of mineral meet the requirements listed in Section 1.
surface roll roofing.If self-sealing 3-tab shingles are used,remove
the exposed tab portion and install with the factory applied adhe- Nail down or remove curled or broken shingles from the existing roof.
sive adjacent to the eaves.Attach the starter course with approved Replace all missing shingles with new ones to provide a smooth base.
fasteners along a line parallel to and 3 in.to 4 in,above the eaves Shingles that are buckled usually indicate warped decking or protruding
edge.The starter course should overhang both the eaves and rake nails.Hammer down all protruding nails or remove them and refasten
edges 1/4 in.to 3/8 in.If a roll roofing is used,seal down the shingles in a new location.Remove all drip edge metal and replace with new.
in the first course by applying adhesive cement in four spots equally
spaced to the surface of the starter strip and press the shingle down If re-roofing over an existing roof where new flashing is required to
on the spots of cement.Plastic cement should be used sparingly, protect against ice dams(freeze/thaw cycle of water and/or the backup'
as excessive amounts may cause blistering. of water in frozen or clogged gutters),remove the old roofing to a point
at least 24 in.beyond the interior wall line and apply TAMKO's Moisture
SHINGLE APPLICATION:There are three different offset methods for Guard Plus®waterproofing underlayment.Contact TAMKO's Technical
applying strip shingles:the 4-inch method,the 5-inch method and the Services Department for more information.
6-inch method.By removing different lengths from the first shingle,
cutouts in one course of shingles do not line up directly with those of The nesting procedure described below is the preferred method for re-
the course below.It is recommended that the shingles be laid accord- roofing over square tab strip shingles with a 5-1/8 in.exposure.
ing to one of these methods consistent with procedures outlined in
ARMNs Residential Asphalt Roofing Manual.This panel will feature the Starter Course:Begin by using TAMKO Shingle Starter or by cutting
4-inch method.For information regarding the other methods,please shingles into 5-1/8 x 36 inch strips.This is done by removing the 5-1/8 in.
refer to the ARMA Residential Asphalt Roofing Manual. tabs from the bottom and approximately 2 in.from thetop of theshingles
CAUTION:Never use an alignment system where shingle joints are
so that the remaining portion is the same width as the exposure of the
i
closer than 4 in.to one another. old shingles.Apply the starter piece so that the self-sealing adhesive
r top lap lies along the eaves and is even with the existing roof.The starter strip
Underlayment _ Deck should be wide enough to overhang the eaves and carry wateY into the
Drip edge . V Eaves Bashing
4__"engutter.Remove 3 in.from the length of the first starter shingle to ensure:
d lap _ (i1 required in lieu of felt) that the joints from the old roof do not align with the new.
Self-sealing
Nail adhesive xposure First Course:Cut off approximately 2 in.from the bottom edge of the
shingles so that the shingles fit beneath the existing third course and align
Start 3rd course `. _-..- - Drip edge with the edge of the starter strip.Start the first course with a full 36 in.'
with 8'removed - TAMKO Starter Shingle
long shingle and fasten according to the instructions printed in Section 3.
Shingles overhang
'•,. drip edge W'to 3/s"
Start 1st course Existing shingles
.
Start 2nd course with fullshingle
with 4"removed
8.LOW SLOPE APPLICATION if) 5
On pitches 2 in.per foot to 4 in.per foot cover the deck with two 1z^
layers of underlayment.Begin by applying the underlayment in a
1/2-sheet width along the eaves and overhanging the drip edge l
by 1/4 to 3/4 in.Place a full-sheet width over the 1/2-sheet width Drip edge
starter piece,completely overlapping it.All succeeding courses will Drip edge
be positioned to overlap the preceding course by 1/2-sheet width.If New shingles
winter temperatures average 25oF or less,thoroughly cement the laps I'
of the entire underlayment to each other with TAM-PRO or TAMKO 5" 3"exposure
Plastic Roof Cement from eaves and rakes to a point of a least 24 in. exposure
inside the interior wall line of the building.As an alternative,TAMKO's
Moisture Guard Plus®self-adhering waterproofing underlayment may
be used in lieu of the cemented felts. Second and Succeedingcourses;According tothe off-set application
ROOK method you choose to use,remove the appropriate length from the
7.MANSARD ROOF OR STEEP SLOPErake end of the first shingle in each succeeding course.Place;the top
If the slope exceeds 21 in. per foot(601, each shingle must be
sealed with TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive edge of the new shingle against the butt edge of the old shingles in the
immediately upon installation.Quarter-sized dabs of cement must courses above.The full width shingle used on the second course will
reduce the exposure of the first course to 3 in.The remaining courses '
be applied to shingles with a 5-1/8 in.exposure,use 6 fasteners per will automatically have a 5-1/8 in.exposure.
shingle.See Section 3 for the Mansard Fastening Pattern.
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 12/12
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 1 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 1 800-228-2656
talmkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO.80216 800-530-8868
f
I
i
® (CONTINUED from page 3)
EUTE GLASS-SSAd�O
TAIN
X0 616ASS-SEAL
BU160ING PRODUCTS 3-TAB ASPHALT SHINGLES
Frederick, MD a Joplin, MO a Tuscaloosa,AL!
9.VALLEY APPLICATION 10.HIP AND RIDGE FAS'T'ENING DETAIL
Over the shingle underlayment,center a minimum 36 in.wide sheet Apply the shingles with a 5-1/8 in.exposure beginning at the bottom
of Moisture Guard Plus®ora minimum 50 lb.roll roofing in the valley. of the hip or from the end of the ridge opposite the direction of the
Nail the underlayment only where necessary to hold it in place and prevailing winds.Secure each shingle with one fastener 5-5/8 in.
then only nail the outside edges. back from the exposed end and 1 in.up from the edge.Do not nail'
IMPORTANT:PRIOR TO INSTALLATION WARM SHINGLES TO directly into the sealant.
PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING TAMKO recommends the use of TAMKO Hip & Ridge shingle
SHINGLES TO FORM VALLEY. products.Where matching colors are available,it is acceptable to
After valley flashing is in place: use TAMKO's Glass-Seal or Elite Glass-Seal shingles cut down to
• Apply the first course of shingles along the eaves of one of the 12 in.pieces.
intersecting roof planes and across the valley, NOTE:Use only Shingles and Hip&Ridge shingles with the Algae
Note:For proper flow of water overthe trimmed shingle,always Relief feature on Glass-Seal'or Elite Glass-Seal shingles with the
start applying the shingles on the roof plane that has the lower Algae Relief feature.
slope or less height.
Fasteners should be 1/4 in.longer than the one used for shingles.
• Extend the end shingle at least 12 in.onto the adjoining roof.
Apply succeeding courses in the same manner,extending them IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS,TO BE
across the valley and onto the adjoining roof. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
• Do not trim if the shingle length exceeds 12 in.Lengths should vary. BENDING SHINGLES IN COOL WEATHER.
• Press the shingles tightly into the valley.
• Use normal shingle fastening methods. THESE ARE THE MANUFACTURER'S APPLICATION
INSTRUCTIONS FOR THE ROOFING CONDITIONSI
Note:No fastener should be within 6 in.of the valley centerline, DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES;
and two fasteners should be placed at the end of each shingle NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
crossing'the valley. DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
• To the adjoining roof plane,apply one row of shingles extending MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW,
it over previously applied shingles and trim a minimum of 2 in. THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE
back from the centerline of the valley. UNDER THE LIMITED WARRANTY. SEE THE LIMITED
• Clip the upper corner of each shingle at a 45-degree angle and WARRANTY FOR DETAILS! IF YOU HAVE ANY QUESTIONS ,
embed the end of the shingle in a3 in.wide strip of asphalt plastic REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE
cement.This will prevent water from penetrating between the CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
courses by directing it into the valley. 800-641-4691.
I
• CAUTION:Adhesive must be applied in smooth, thin, even
layers.Excessive use of adhesive will cause blistering to this Direction of prevailing wind
product.TAMKO assumes no responsibility for blistering. Start 5"exposure
here— 1"
6i. a
36'wide sheet " Fastener
here—
Valley centerline
of Moisture Guard Plus No fasteners within n Y 6
or 50 to.or heavier 6'o1 centerline
roll roofing Extra fastener in Start
Undedayment
end of shingle beta 5"exposure
I •
Extend end shingle
at least 12'beyond TAMKO',Moisture Guard Plus°,Tam-ShieW,TAM-PROs and Elite Glass-Seal°are
Asphalt plastic valley centerline registered trademarks of TAMKO Building Products,Inc.
cement
1'clipped o8 comer Information included in these application instructions was current at time of printing.
at 45° To obtain a copy of the most current version of these application Instructions,visit us online
at tamko.com or call us at 800-641-4691'.
I
shingles/trimm de 2'back
/from valley centerline \
FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
800-641-4691.
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 12112
Visit Our Web Site at
Northeast District 4500 Tamko Dr., Frederick,MD 21701 I 800-368-2055
I
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4
I