Loading...
HomeMy WebLinkAboutNotice of Acceptance2�EAGLEVIEW' TECHNOLOGIES Premium .Rep®rt March 22, 2017 Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this. roof is 3/12. fiA S ARE A VIOARMOSf- FoRti'ON n F R00fi W N S 6 Note: This diagram contains labeled pitches for facet areas larger than 20 square feet. In some cases, pitch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. This domment is provided under License by EagleView, Technologies to the requestor for their Internal Use Only subject to the terms and conddions previously agreed to by the requestor when they registered for use of EagleView, Technologies Services. It remains the property of EagleView Technologies and may be reproduced and distributed only within the requr stor's company. Any reproduction or distribution to anyone outside of the requestofs company without EagleView's prior written permission is strictly prohibited. Al aspects and handling of this report are subject to the Tema and Conditions previously agreed to by the requester. Copyright ©2008-2017 EagleView Technologies, Inc —All Rights Reserved — Covered by U.S. Patent Nos. 8,078,438; 8,145,578; 8,170,840; 8,209,152; 8,515,125. Other Patents Pending. PAGE 5 f.ry i } i. • �3 .. 3-s s - f :'1 ' S t— 3 #. 3 VIOARMOSf- FoRti'ON n F R00fi W N S 6 Note: This diagram contains labeled pitches for facet areas larger than 20 square feet. In some cases, pitch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. This domment is provided under License by EagleView, Technologies to the requestor for their Internal Use Only subject to the terms and conddions previously agreed to by the requestor when they registered for use of EagleView, Technologies Services. It remains the property of EagleView Technologies and may be reproduced and distributed only within the requr stor's company. Any reproduction or distribution to anyone outside of the requestofs company without EagleView's prior written permission is strictly prohibited. Al aspects and handling of this report are subject to the Tema and Conditions previously agreed to by the requester. Copyright ©2008-2017 EagleView Technologies, Inc —All Rights Reserved — Covered by U.S. Patent Nos. 8,078,438; 8,145,578; 8,170,840; 8,209,152; 8,515,125. Other Patents Pending. PAGE 5 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply. with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Gardner Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 12-1120.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA: 15-0707.09 MIAMI•DADE COUNTY Expiration Date: ; 03/28/18 Approval Date: 04/06/17 Page 1 of 4 M1AN11MADE MUM-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) Hww.miamidaae.eov/economy Gardner Asphalt Corporation 4161 W. 71 Avenue Tampa, FL. 33605 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply. with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Gardner Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 12-1120.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA: 15-0707.09 MIAMI•DADE COUNTY Expiration Date: ; 03/28/18 Approval Date: 04/06/17 Page 1 of 4 i J ROOFING COMPONENT APPROVAL Category Roofmg Sub -Category: Underlayment Material: Asphalt TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Descrintion APOC Tuff -Felt 26 36" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2 Manufacturing square #30. Location #1, 2 United FGUR20 36" x 72' rolls Manufacturing Location #1, 2 APOC Tuff -Felt 46 36" x 144' rolls Manufacturing Location #1, 2 United FGUR10 36" x 144' rolls Manufacturing Location #1, 2 United FGUR70 18" x 72' rolls Manufacturing Location #1, 2 GatorSkin 42" x 285.8' rolls Manufacturing Location #3 ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2 square #30. ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 square #15. ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 square # 15. ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1 square #30. ASTM D 226 Type II Synthetic roof underlayment comprised of layers of polyolefin film. Weather -Armor CX -L 37.25" x 145' rolls ASTM D 226 Type II High strength hybrid underlayment Manufacturing comprised of two layers of polyolefin and Location 93 polyester synthetic fabric with a thin layer of modified bitumen between the two plies. Weather -Armor SB -1 36" x 65' 8" rolls ASTM D 1970 Glass fiber reinforced, polymer modified Manufacturing asphalt, granulated self -adhered Location #4 underlayment. NOA: 15-0707.09 M1AM1•DADE COUNTY Expiration Date: 03/28/18 Approval Date: 04/06/17 Page 2 of 4 MANUFACTURING LOCATIONS: 1. Tacoma, WA. 2. Eutaw, AI - 3. Hangzhou, China. 4. Springville, AL. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GGI-100-02-01 ASTM D 226 06/22/12 Technologies GGI-101-02-01 ASTM D 226 06/22/12 GGI-132-02-01 ASTM D 226 04/28/15 GGI-176-02-01 ASTM D 226 09/26/16 GGI-178-02-01 ASTM D 1970 10/25/16 INSTALLATION 1. Gardner Underlayments listed herein shall be installed in strict compliance with applicable Building Codes. 2. Gardner Underlayments listed herein shall be installed with a minimum 4 -inch head lap and 6 -inch side laps. 3. APOC-Tuff Felt 26, United FGUR20, APOC-Tuff Felt 46, United FGUR10; United FGUR70, GatorSkin, and Weather Armor CX -L shall be fastened with corrosion resistant tin -caps and approved roofing nails spaced 6 inches o.c. minimum at all laps and three staggered rows fastened at 12 inches 'o.c. minimum in the field of the roll. Nails shall be driven flush and 90 degrees to the roof deck. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. NOA: 15-0707.09 Expiration Date: ; 03/28/18 Approval Date: 04/06/17 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance. with applicable building code. 3. Weather -Armor SB -1 shall not be hot mopped; refer to manufacturer's published literature for product compatibility. 4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. Gardner Underlayments listed herein shall not be left exposed as a temporary roof for longer than 30 days of application. 6. APOC-Tuff Felt 26, United FGUR20, APOC-Tuff Felt 46, United FGUR10, and United FGUR70 may be used with Asphalt shingles, Wood shakes and shingles, Non-structural metal roofing, quarry slate, and as an anchor sheet in tile roof assemblies. 7. GatorSkin, Weather Armor CX -L, and Weather -Armor SB -1 may be used with Asphalt shingles, Wood shakes and shingles, Non-structural metal roofing, and quarry slate. 8. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance. If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 9. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a current Approved Roofing Materials Directory for fire ratings of this product. 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA: 15-0707.09 MIAMI•DADE COUNTY Expiration Date: 03/28/18 Approval Date: 04/06/17 Page 4 of 4 _1 v ,,I I RINIIY I ERD EVALUATION REPORT Owens Corning . One Owens Corning Parkway Toledo, OH 43659 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 037940.02.12-R7 FL10674-1112 Date of Issuance: 02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD: requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle: ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ER, D Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shalfbe done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided tothe user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/18/2016. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. . 2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 4 \(I RINIIY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Enti Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality,Control Service Confirmation, R2453 Exp. 08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme® are fiberglass reinforced, 3 -tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles. 4.1.3 Devonshird' are fiberglass reinforced, 5 -tab asphalt roof shingles. 4.1.4 Duration®, TruDefinition' Duration®, Duration® Premium Cool, TruDefinition® Duration® Designer Color m Collection, TruDefinition Oakridge , Oakridge and WeatherGuard HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTM' Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-117 Certificate of Authorization 119503 FL10674-1112 Revision 7:04/18/2016 Page 2 of 8 ��TRINrryj ER® 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasil = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V,,It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the.shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. ' 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507:2.3, 1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. ➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle. ➢ Devonshire'" shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing — Starter Strip Shingle and Starter Strip Plus: Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Feltundertayment Dock Sell -adhered i Weatherl,ocklD underlayment Drip edge edge Na is located 2'-3' fmm eave InsSdfrtealing adhesive wit 6" rst emoveStarter Strip Plus positioned along eave with 6" removed Starter Strip Ples overhangs eaves and rakes 1!41-314' Evaluation Report 037940.02.12-R7 FL10674-R12 Revision 7:04/18/2016 Page 3 of 8 6.2.6 Minimum Nailing — Classic®& Supreme: Normal Mansard.or Area para Win d,Areas High Wind desvenes y Area para vientos normalee Areasi vientos faertes 5'Exposure Exposiel6n 6.2.7 Minimum Nailing— Berkshire®: Standard Fastening Pattern Exterior Research and Design, I.I.C. Certificate of Authorization #9503 �f I KININ (ERD Normal Mansard or Area pare Wind Areas High Wind desvanes.y Area para vientos normales Areas vientos fuertes, �' (A) r' ('t' Z'. ie) z' .'-� ,z, ,21 6.5/8" Exposure Exposiei6a Sealant strip La tira de seflador Sw" 8W, 8w 8th•• j J r r 6 -Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern Evaluation Report 037940.02.12-R7 FL10674-R12 Revision 7: 04/18/2016 Page 4 of 8 6.2.8 Minimum Nailing— DevonshireTm: 1=- i 7" i 8" i 8n i 8" Na davos M/8'exposure Sealant location Exposici6n de 5.5/8 pull; Ubicad6n del sellador . Standard 6 -Nail Fastening Pattern �I TRINITYIERD Nails r r e r ss. % SW .• Ten 1° Spots of Asphalt Roof Cement Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing— Duration®, TruDeffnition® Duration, Duration® Premium Cool & TruDefinition Duration Designer Color Collection: 4 -Nail Fastening Pattem SWSNaft fastening ansa width Nag. Typical 12" 7• �...". ce„ma sr<.ua •^ s✓i= a �o - :• o."u c=mwsw+ay. .,:�-. Standard Fastening Pattern Exterior Research and Design, LLC. Certiflcate ofAuthorization#9503 6 -Nail Fastening Pattern Fastenfng for Slopes Greater Than 21:12 SwoNa89 Wstoning area width /r Nall, typical 1• 12" I I . 12" E.Ua"O_TSYtI" z Fowl- Spats clAsphalt Roonng Cement Mansard or Steep Slope Fastening Pattern Evaluation Report 037940.02.12-R7 FU0674-R12 Revision 7:04/18/2016 Page 5 of 8 6.2.1 Minimum Nailing — Tru Definition' Oakridge®, Oakridge®: 4 Nail Pattern Esquema con 4. clavos 5518"Exposure . ExposFe 6a 66 618pulg. Clews Expos1d6n'de.5612 ping. Standard Fastening Pattern \I TRINITY I ERD 6'Nail Mom Esquema•con 6 clavos r r Nails 5518" Exposure Claws 5 5ff Expoguie` Evposkfcrr de 6610pulg Expaskidn de 6619patg.- 6-Nail Fastening Pattern 6.2.1 Minimum Nailing — WeatherGuard® HP: 800010,,Sit4 Mew � z 1-~% - ~7 '— �I . YliErlrEval .s; ::• :':•,s,'� li�l�wte71�� Nil Llns: . Ciwar�ntritril�die Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorizatian 119503 FL10674-R12 Revision 7:04/18/2016 Page 6 of 8 V I (�ININ ERD 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuard® HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current, published instructions, using four (4) nails per shingle. Installation of DuraRidge' Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire" Hip & Ridge and High Ridge: Fig,2 1 Top View I SideVim NalsNals Top LanUlated 2" � d' piece I� i I i I dl JI 8' Ej I VI I I I I ttn� 6.3.4 Minimum Nailing— WeatherGuard® HP Hip and Ridge: Fig. A- 4 4 Preva0ing Wind �— Dlrea., A flails A 44 A I I i I A I I I I I I I I �(— SUr � r:iPOsure Exterior Research and Design, LLC. Certificate of Authorization #9503 Fig. G Hip'& Ridge: Shing'le'Faslening TopVkv� Naps Nalls r 7• 2,. 11 6' mposure. .. 1z Evaluation Report 037940.02.12-117 FL10674-R12 Revision 7:04/18/2016 Page 7 of 8 t 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip A--" 6° Exposure Fasten 71h° Cover Exposed Fasteners with Roof Cement_ Standard X11"—• Fastening Pattern 7 "I i".I YI•I I"1' 12' I Sealant 7'/:' 6" Exposure 1 6.3.6 Minimum Nailing — DuraRidgeTm Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. F?osaiing Wind Di"c6m r— DirottiondomimntockiwAt Dirood6n dol visnta prwkrnimnto i CtaOU tot\ I I e -t poll, Top View Vue en plan HII' Vismsuperlor ci 2 j r •.` Ovrcns Coming SmcNair • �iO � I I Ie aims V 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (414) 248-6409; karen.buchmann(@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization #9503 FL10674-1112 Revision 7: 04/18/2016 Page 8 of 8