HomeMy WebLinkAboutProduct Approval --- Florida Buildin�odc a OriTine --- Page 1 of 2
-
,.�d BCIS Hpme( Lo91n .:.. :. ..;.. ( _ a...- ! . ... :.5'. . ..:_.... .._
Ord 3 i�:�dltfllCs,t f User Registration Hot Topics i Submit Surcharge (Stats&Facts i Publics
Ions FBC Staff f SCIS Site Map Links Search
Busines
Professial Product Approval
I� :USER:Public User
RegulationCMMMIMIMM -
Pmduct Approval Menu>Product or Application Search>Application List>Application Uatail
at _
FL# FL10124-R5
>sy Application Type Revision
mJa a � Code Version 2010
`F? ' Application Status Approved
Comments
Archived t ,
Product Manufacturer GAF
Address/Phone/Email 1361 Alps Road
Wayne,NJ 07470
(973)872-4421 I;
Iindareith@trinityerd.com
Authorized Signature Beth McSorley
Iindareith@trinityerd.com
i
Technical Representative Beth McSorley
Address/Phone/Email 1361 Alps Road-Bldg 11-1
Wayne,NJ 07470
(973)872-4421
BMcSorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles I'
I'
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
F�i Evaluation Report-Hardcopy Received
I
Florida Engineer or Architect Name who Robert Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity Underwriters Laboratories Inc. !1,
Quality Assurance Contract Expiration Date 05/17/2012
Validated By John W.Knezevich,PE
iii Validation Checklist-Hardcopy Received
Certificate of Independence FL10124 R5 COI Trinitv ERD CI-Nieminen odf
Referenced Standard and Year(of Standard) Standard Year
I
ASTM D3161(Class F) 2006
ASTM D3462 2007
ASTM D7158(Class H) 2007
TAS 107 1995
Equivalence of Product Standards
I ,
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQWtDquracBeVCbdMQNZD... 2/1/2012
- Florida=Building Code Orihne -- ------ Page 2 of 2
Certified By
Sections from the Code
I'.
Product Approval Method Method 1 Option D
Date Submitted 12/12/2011
Date Validated 12/15/2011
Date Pending FBC Approval 12/21/2011
Date Approved 01/31/2012
Summary of Products
FL#- - _ - -Model,Number or Name Description '.
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,,laminated,5-tab and
hip/ridge asphalt Shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10124 R5 II er121211FINAL GAF Asphalt
Approved for use outside HVHZ:Yes Shin les FL10124-R5. df
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10124 R5 AE:Ier1212111FINAL GAF Asphalt
Shingles FL10124-R5.odf
Created b IndependentTfiird Party:Yes
I
Back Next
I
Contact Us::1940 North Monroe Street,Tallahassee FL 32399
The State of Florida is an AA/EEO employer.Copyright 2007-2010 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,e-mail addresses are public records.If you do not want your e-mail address relel sed In response to a public-records request,do not
send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions regarding DBPR's ADA web
accessibility,please contact our Web Master at webmasterfradbpr.state.fl.us.
Product Approval Accepts:
s curitvaurrtttcs
• I
i
I
I ;
I
I '
h4://floridabuilding.org/pr/pr_app_dtl.aspx?paramwGEVXQWtDquracB eVCb'dMQNZD... 2/1/2012
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization#9503
.. 353 CHRISTIAN STREET, UNIT#13
rTRINITY OXFORD, CT 06478
t PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
GAF - - -- Evaluation Report 01506MM-1117 -
1361 Alps Road, Building 7-3 FL10124-RS
Wayne, N7 07470 Date of Issuance: 01/03/2008
Revision 7: 12/12/2011
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable pules and regulations governing
the use- of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described Wherein;have been designed to
comply with the 2010 Florida Building Code sections noted herein. ,I
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such;tune as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinitylERD requires a complete. review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.11
ADVERTISEMENT: The Evaluation Report number preceded by the words"TrinitylERD Evaluated"may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be,provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
11 '�
This Evaluation Report consists of pages 1 through 4.
Prepared by:
` 1=-E The facsimile seal appearing was authorized
r5+n #= u c by Robert Nleminen,P.E.on 12/12/2011
This does not serve as an electronically signed
Robert J.M. Nieminen P.E. ' ''
t��`S O `��`. document. Signed,sealed hardcopies have been
Registration No. 59166 Florida DCA ANE1983 '����••�����"' transmitted to the Product Approval Administrator and
Florida Re
9 to the named client
I
CERTIFICATION OF INDEPENDENCE:
1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products,it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or distributing products for which
the evaluation reports are being Issued.
4. Robert Nieminen, P.E, does not have, nor will acquire, a financial interest in any other entity involved In the approval process of the
product.
I
I ,
TRINITY�ERD
ROOFING SYSTEMS EVALUATION: j
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by 'GAF, have demonstrated
_compliance with the: following sections of the Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject
to the Installation Requirements and Limitations/ Conditions of Use set forth Herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007
1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 j 1995
3. REFERENCES:
Entity Examination Reference Dae .
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 j 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161, 133462 06CA18074 j 06/16/2006
UL(TST 1740) ASTM 133161, 133462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161, 133462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161, D7158, D3462 0BCA0610D 03/13/2008
UL(TST 1740) ASTM D3161, D3462 07CASS908 04/01/2008
UL(TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158, D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158, D3462 10CA355% 03/05/2010
UL(TST 1740) ASTM D3161,D7158, D3462 1OCA13686 05/15/2010
UL(TST 1740) ASTM D3462 10CA07264 j 05/27/2010
UL(TST 1740) ASTM D3462 1OCA11953 10/29/2010
UL(TST 1740) ASTM D3161, D7158, D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161, D7158, D3462 1ONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158, D3462 08CA0610D 01/30/2010
UL(TST 1740) ASTM D3161,D7158, D3462 1OCA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158, D3462 11CA48924 10/22/2011
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R7
Certificate of Authorization#9503 FL10124-RS
Revision 7: 12/12/2011
Page 2 of 4
I,
i
I!
I'
II
F ,Y- - D
TRINITY ERD
UL(TST 1740) ASTM D3161,D7158, D3462 11CA47919 l 12/03/2011
UL(TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011
UL(QUA 1743) Quality Control Inspection Report, File No. R21 05/17/2011
UL(QUA 1743) Quality Control R3915 Current
4. PRODUCT DESCRIPTION:
4.1 Marquis WeatherMax, Royal Sovereign and Sentinel are a fiberglass'reinforced, 3-tab asphalt
roof shingles.
4.2 Camelot, Camelot II/ Camelot 30, Camelot IR, Capstone, Country Mansion, Country Mansion II,
Grand Canyon, Grand Sequoia, Grand Slate, Grand Slate II, Monaco, Timberline American
Harvest, Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow
Arctic White erli a HD Timberline Prestique 30,Timberline Prestique 40 /Timberline Cool
Series, Timberline tra HD / Timberline Prestique Lifetime, iTimberline Majestic / Timberline
Majestic 30 and Woodland are fiberglass reinforced, laminated iasphalt roof shingles.
4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle.
4.4 Seal-A-Ridge, Seal-A-Ridge Armorshield, Ridglass 8, Ridglass 10, Ridglass 12 and Timbertex Hip
and Ridge are fiberglass reinforced, hip and ridge asphalt roof shingles'.
4.5 ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles are a starter strips for
asphalt roof shingles.
I I
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are
acceptable for us in all wind zones up to Vasa = 150 mph (V,,,t,= 194;mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.3.2 All GAF hip & ridge shingles noted herein are Classified 'in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for
us in all wind zones up to Vasa = 150 mph (V,,,t = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B, or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 9N-3, per FBG Section's 1507.2.3, 1507.2.4 or
R905.2.3.
6.2 Starter Shingles:
i
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R7
Certificate of Authorization#9503 FL10124-R5
Revision 7: 12/12/2011
i
Page 3 of 4
i
I
TRINITY I`ERD
6.2.1 Installation of ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles shall
comply with the manufacturer's current published instructions:'
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the mI.anufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
_.or.11905.2,.with the fol Iowl ng.exceptions: . -_
➢ Camelot, Camelot II/ Camelot 30, Camelot IR, Grand Slate II, Country Mansion II, Monaco
and Woodland require minimum five (5) fasteners per shingle j
6.3.2 Fasteners shall be in accordance with manufacturer's publisheld requirements, but not less than
FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Ridglass 8, Ridglass 10 and Ridglass 12 asphalt shingles shall comply with the
manufacturer's current published instructions with a minimum two (2) nails per side [total of
four(4) nails per shingle] and asphalt roofing cement.
6.4.2 Installation of Seal-A-Ridge and Seal-A-Ridge Armorshield asphalt shingles shall comply with
the manufacturer's current published instructions with a minimum two (2) nails per shingle.
6.4.3 Installation of Timbertex Hip and Ridge asphalt shingles shall comply with the manufacturer's
current published instructions with a minimum two (2) mails per shingle and beads of
Sonneborn NP1 Gun Grade Polyurethane Sealant, Henkel PL Roofing and Flashing Sealant or
TopCoat FlexSeal Adhesive.
I
6.4.4 Fasteners shall be in accordance with the manufacturer's published 'requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
I
7. LABELING:
I
7.1 Each unit shall bear a permanent label with the manufacturer's name; logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1/ R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction In order'to properly evaluate the
installation of this product.
�I I
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
Underwriters Laboratories - QUA1743; (847) 664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. (Evaluation Report 01506.01.08-R7
Certificate of Authorization#9503 FL10124-R5
Revision 7: 12/12/2011
Page 4 of 4
I;
f